Viessmann Vitodens 100-W B1HA 26, 94 vs B1HA 35, 125

Verdict in brief

The B1HA 26, 94 and B1HA 35, 125 are the two heating-only models of the B1HA generation and share the 79.4 lb (36 kg) cabinet, 95.0% AFUE, 1.02 USG water content and 45 psig rating. The 35, 125 fires to 125 MBH natural gas against 94 MBH, with a 101 MBH Net AHRI rating against 76.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitodens 100-W B1HA 26, 94 and Viessmann Vitodens 100-W B1HA 35, 125
SpecificationViessmann Vitodens 100-W B1HA 26, 94Viessmann Vitodens 100-W B1HA 35, 125
CSA input, minimum (natural gas)21 MBH21 MBH
CSA input, maximum (natural gas)94 MBH125 MBH
CSA input (liquid propane)31-94 MBH31-125 MBH
CSA output / DOE heating capacity (natural gas)20-87 MBH20-116 MBH
Net AHRI rating76 MBH101 MBH
Efficiency (AFUE)95 %95 %
Weight79.4 lb79.4 lb
Maximum operating pressure45 psig45 psig

What actually separates them

Both boilers are wall-hung condensing models with a 21 MBH (6.2 kW) natural gas minimum input, 20 MBH output floor and a 31 MBH propane minimum. They share the 400 x 400 x 768 mm cabinet, 79.4 lb (36 kg) weight, 88.2 lb shipping weight and 45 psig maximum operating pressure.

Maximum input separates them: 94 MBH (27.5 kW) natural gas on the 26, 94 against 125 MBH (36.6 kW) on the 35, 125, with propane ranges of 31-94 and 31-125 MBH. Outputs top at 87 and 116 MBH, and Net AHRI ratings read 76 and 101 MBH at the same 95.0% AFUE.

Neither model produces domestic hot water; both pair with an indirect tank, and the B1KA 35, 125 combi covers on-demand DHW in the same generation. The heat-loss calculation decides the ceiling, and both models are documented in the B1HA/B1KA technical data manual (doc 5784 566 - 12).

DiscontinuedHistorically in Canada
Input
21–94 MBH
Output (max)
AFUE
95 %

The Vitodens 100-W B1HA 26, 94 is the smaller heating-only model of the B1HA/B1KA generation: 21 to 94 MBH natural gas input at 95.0% AFUE in a 79.4 lb (36 kg) wall-hung boiler.

Natural gasPropaneHeating-only

Frequently asked questions

Are the B1HA 26, 94 and 35, 125 the same size?

Yes. Both weigh 79.4 lb (36 kg) and measure 400 x 400 x 768 mm (15¾ x 15¾ x 30¼ in) with 1.02 USG of boiler water.

Do both models make domestic hot water?

No — both are heating-only and use an indirect tank. The B1KA 35, 125 is the combi model of the same generation.

What are the firing ranges?

21-94 MBH natural gas on the 26, 94 and 21-125 MBH on the 35, 125, with propane minimums of 31 MBH on both.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.