Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Viessmann Vitogas 100 GS1-48 vs GS1-60

Verdict in brief

The GS1-48 and GS1-60 are the two largest Vitogas 100 GS1 boilers: 190 and 240 MBH input, 161 and 203 MBH output, with Net I=B=R ratings of 140 and 177 MBH. The GS1-60 adds two sections and two burners, grows 180 mm wider, and weighs 101 lb more, while its printed AFUE eases from 85.5% to 85.4%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Viessmann Vitogas 100 GS1-48 and Viessmann Vitogas 100 GS1-60
SpecificationViessmann Vitogas 100 GS1-48Viessmann Vitogas 100 GS1-60
CSA input (natural gas)190 MBH240 MBH
CSA output / DOE heating capacity161 MBH203 MBH
Net I=B=R rating140 MBH177 MBH
Efficiency (AFUE)85.5 %85.4 %
Cast iron sections68
Weight (boiler with insulation, burner and control)481 lb582 lb
Boiler water content4.7 USG5.8 USG
Overall width930 mm1,110 mm

What actually separates them

Both models sit on the wide GS1 chassis with the same 864 mm length and 845 mm height, at 60 psig maximum operating pressure. The GS1-48 fires at 190 MBH (56 kW) input with 161 MBH (47 kW) output; the GS1-60 at 240 MBH (70 kW) with 203 MBH (60 kW) output.

The GS1-60 is the largest GS1 build: eight cast-iron sections and nine burners against the GS1-48's six and seven, at 1110 mm (43¾ in) overall width against 930 mm (36½ in). Weight rises from 481 to 582 lb (218 to 264 kg) and water content from 4.7 to 5.8 USG.

AFUE prints 85.5% on the GS1-48 and 85.4% on the GS1-60 — the lowest figure in the GS1 range. Both are atmospheric, chimney-vented boilers with draft hood and vent damper, documented in Viessmann Canada's historic manuals.

Frequently asked questions

How much wider is the GS1-60 than the GS1-48?

1110 mm (43¾ in) against 930 mm (36½ in), with the same 864 mm length and 845 mm height.

What are the firing ranges?

190 MBH (56 kW) input / 161 MBH output on the GS1-48, and 240 MBH (70 kW) input / 203 MBH output on the GS1-60, with Net I=B=R ratings of 140 and 177 MBH.

Which GS1 size should a load near 200 MBH use?

The GS1-48 covers loads up to 190 MBH; a design load approaching or exceeding that points to the GS1-60 at 240 MBH. Sizing follows the heat-loss calculation.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate