Weil-McLain CGi-5 vs CGi-6

Verdict in brief

Weil-McLain CGi-5 and Weil-McLain CGi-6 are two non-condensing boilers from the Weil-McLain CGi (cast iron) line. The Weil-McLain CGi-5 is documented at 119 MBH input, 102 MBH output and 84% AFUE, while the Weil-McLain CGi-6 is documented at 158 MBH input, 135 MBH output and 84% AFUE. Weil-McLain CGi-6 lists 39 MBH more input than Weil-McLain CGi-5 (158 MBH against 119 MBH). Both list the same published AFUE of 84%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain CGi-5 and Weil-McLain CGi-6
SpecificationWeil-McLain CGi-5Weil-McLain CGi-6
Input, maximum119 MBH158 MBH
DOE heating capacity102 MBH135 MBH
Efficiency (AFUE)84 %84 %
VentingCategory I B-vent (chimney) or Category III AL29-4C stainless steel (sidewall)Category I B-vent (chimney) or Category III AL29-4C stainless steel (sidewall)
FuelNatural gas or propaneNatural gas or propane
Net AHRI water rating89 MBH117 MBH

What actually separates them

Published ratings: the Weil-McLain CGi-5 is rated 119 MBH input, 102 MBH output and 84% AFUE; the Weil-McLain CGi-6 is rated 158 MBH input, 135 MBH output and 84% AFUE. Weil-McLain CGi-6 lists 39 MBH more input than Weil-McLain CGi-5 (158 MBH against 119 MBH). Both list the same published AFUE of 84%.

Both records print the same AFUE (84%), venting (Category I B-vent (chimney) or Category III AL29-4C stainless steel (sidewall)) and fuel (Natural gas or propane), per the cited sources.

DiscontinuedHistorically in Canada
Input
Output (max)
102 MBH
AFUE
84 %

The CGi-5 is the first of the larger CGi Series 5 sizes, from the cast iron line Canada discontinued in 2023: 119 MBH CSA input, 102 MBH DOE heating capacity and an 89 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
135 MBH
AFUE
84 %

The CGi-6 steps the CGi Series 5 line to 158 MBH CSA input with 135 MBH of DOE heating capacity — an 84% AFUE cast iron boiler from the line Canada discontinued in 2023.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Weil-McLain CGi-6 lists 158 MBH, against 119 MBH on the Weil-McLain CGi-5, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 84%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate