Weil-McLain GV90+3 vs GV90+4

Verdict in brief

The GV90+3 and GV90+4 share the 30-3/4" cabinet, 3" venting and 91%-plus AFUE of the Series 2 line; the +4 steps input from 70 to 105 MBH and DOE heating capacity from 65 to 97 MBH, while efficiency drops slightly from 91.9% to 91.2% AFUE.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain GV90+3 and Weil-McLain GV90+4
SpecificationWeil-McLain GV90+3Weil-McLain GV90+4
Input, maximum70 MBH105 MBH
DOE heating capacity65 MBH97 MBH
Net AHRI water rating57 MBH84 MBH
Efficiency (AFUE)91.9 %91.2 %
Weight313 lb353 lb
Boiler water content3.8 gal4.7 gal
Venting3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe on all GV90+ sizes

What actually separates them

Both are Series 2 GV90+ high-efficiency cast iron boilers with the stainless steel secondary heat exchanger, built-in low water cut-off, 3" Category IV venting to 100 ft, and the same 30-3/4" cabinet length.

The GV90+4 steps input from 70 to 105 MBH, DOE heating capacity from 65 to 97 MBH and the net AHRI rating from 57 to 84 MBH (manual figures), while its 91.2% AFUE sits just under the +3's 91.9% — the top rating in the line. Water content grows from 3.8 to 4.7 gallons and shipping weight from 313 to 353 lb.

Both connect with 1" NPT supply and return fittings and 1/2" NPT gas, and both are heating-only boilers matched with an indirect tank for domestic hot water. The heat-loss calculation decides between the 65 and 97 MBH output ceilings.

CurrentSold in Canada
Input
Output (max)
65 MBH
AFUE
91.9 %

The GV90+3 is the smallest Series 2 GV90+: 70 MBH input, 65 MBH DOE heating capacity and a 91.9% AFUE rating — the highest in the line — from the cast iron boiler with stainless steel secondary heat exchanger.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
Output (max)
97 MBH
AFUE
91.2 %

The GV90+4 steps the cast iron line to 105 MBH input and 97 MBH DOE heating capacity at 91.2% AFUE, keeping the 30-3/4" cabinet length with 4.7 gallons of boiler water.

Natural gasPropaneHeating-only

Frequently asked questions

Which GV90+ is more efficient?

The GV90+3 at 91.9% AFUE; the GV90+4 rates 91.2%. Both exceed the ENERGY STAR threshold cited in Weil-McLain's brochure.

Are the +3 and +4 the same physical size?

The cabinet length is the same at 30-3/4", but the +4 is heavier (353 lb shipping) and holds more water (4.7 versus 3.8 gallons).

When does the GV90+4 make sense?

When the heat-loss calculation exceeds the +3's 65 MBH of DOE output on a design day.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate