Weil-McLain Ultra 105 vs Ultra 155

Verdict in brief

The Ultra 155 is where the Series 4 Ultra stops offering 2" venting: input rises from 105 to 155 MBH at the same 94.0% AFUE, but venting becomes 3"-only to 100 ft, water content grows to 1.17 gallons and weight to 234 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain Ultra 105 and Weil-McLain Ultra 155
SpecificationWeil-McLain Ultra 105Weil-McLain Ultra 155
Input, maximum105 MBH155 MBH
Input, minimum21 MBH31 MBH
DOE heating capacity94 MBH139 MBH
Net AHRI water rating82 MBH121 MBH
Efficiency (AFUE)94 %94 %
Weight207 lb234 lb
Boiler water content0.82 gal1.17 gal
Venting2" or 3" PVC, CPVC, polypropylene or stainless steel (Category IV)3" PVC, CPVC, polypropylene or stainless steel (Category IV); 3" pipe only on the 155

What actually separates them

Both Ultras are 5:1-modulating, 94.0% AFUE Series 4 boilers with 1" NPT supply and return tappings and 1/2" NPT gas. The 155 steps input from 105 to 155 MBH, DOE heating capacity from 94 to 139 MBH and the net AHRI rating from 82 to 121 MBH, with low fire climbing from 21 to 31 MBH.

The practical change is venting: the 105 runs 2" or 3" to 100 ft, while the Series 4 manual allows only 3" pipe on the 155. A mechanical room planned around a 2" route therefore drives the choice down to the 105 unless the route can be reworked.

Water content and weight also step up — 1.17 gallons and 234 lb against 0.82 gallons and 207 lb — while the altitude allowance stays at 5,500 ft. Size from the heat-loss calculation first, then confirm the vent route fits.

CurrentSold in Canada
Input
21–105 MBH
Output (max)
94 MBH
AFUE
94 %

The Ultra 105 adds 25 MBH of input over the 80: 105 MBH maximum, 21 MBH low fire, 94 MBH DOE heating capacity and 94.0% AFUE from the same nano-coated cast aluminum Series 4 platform.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
31–155 MBH
Output (max)
139 MBH
AFUE
94 %

The Ultra 155 is the first Series 4 Ultra to require 3" venting: 155 MBH input, 31 MBH low fire, 139 MBH DOE heating capacity and 94.0% AFUE from the cast aluminum condensing block.

Natural gasPropaneHeating-only

Frequently asked questions

Can the Ultra 155 vent in 2" pipe?

No. The Series 4 manual allows 2" only on the Ultra 80 and 105; the 155 is 3" pipe only, to 100 ft.

How much bigger is the Ultra 155?

It ships at 234 lb against 207 lb and holds 1.17 gallons against 0.82 gallons; the low fire rises from 21 to 31 MBH.

Are both models 94.0% AFUE?

Yes — the Ultra 105 and 155 are both rated 94.0% AFUE at 5:1 modulation.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.