Weil-McLain Ultra 80 vs Ultra 105

Verdict in brief

The Ultra 80 and 105 are the two smallest Series 4 Ultras and share the same cabinet and 2"-or-3" venting; the 105 adds 25 MBH of input, raises AFUE from 93.5% to 94.0%, and its low fire climbs from 16 to 21 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain Ultra 80 and Weil-McLain Ultra 105
SpecificationWeil-McLain Ultra 80Weil-McLain Ultra 105
Input, maximum80 MBH105 MBH
Input, minimum16 MBH21 MBH
DOE heating capacity71 MBH94 MBH
Net AHRI water rating62 MBH82 MBH
Efficiency (AFUE)93.5 %94 %
Weight199 lb207 lb
Boiler water content0.69 gal0.82 gal
Venting2" or 3" PVC, CPVC, polypropylene or stainless steel (Category IV)2" or 3" PVC, CPVC, polypropylene or stainless steel (Category IV)

What actually separates them

Both models use the nano-coated cast aluminum Series 4 block at 5:1 modulation, vent in 2" or 3" pipe to 100 ft, connect with 1" NPT supply and return tappings and 1/2" NPT gas, and need no altitude modification to 5,500 ft.

The 105 raises input from 80 to 105 MBH, DOE heating capacity from 71 to 94 MBH and the net AHRI rating from 62 to 82 MBH, and its 94.0% AFUE beats the 80's 93.5%. Its low fire steps from 16 to 21 MBH, so in a very low-load home the 80 tracks mild weather slightly more closely.

The manual warns that 2" vent runs derate by up to 10% on the 80 and 15% on the 105 at a full 100 ft, which favours 3" pipe on longer runs for either model. The choice follows the heat-loss calculation: 94 MBH of DOE output on the 105 versus 71 on the 80.

CurrentSold in Canada
Input
16–80 MBH
Output (max)
71 MBH
AFUE
93.5 %

The Ultra 80 is the smallest Series 4 Ultra: 80 MBH input with a 16 MBH low fire, 71 MBH DOE heating capacity and 93.5% AFUE from a nano-coated cast aluminum condensing block.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
21–105 MBH
Output (max)
94 MBH
AFUE
94 %

The Ultra 105 adds 25 MBH of input over the 80: 105 MBH maximum, 21 MBH low fire, 94 MBH DOE heating capacity and 94.0% AFUE from the same nano-coated cast aluminum Series 4 platform.

Natural gasPropaneHeating-only

Frequently asked questions

What are the differences between the Ultra 80 and 105?

Input rises from 80 to 105 MBH, DOE heating capacity from 71 to 94 MBH, low fire from 16 to 21 MBH, and AFUE from 93.5% to 94.0%.

Do both models vent the same way?

Yes — 2" or 3" pipe to 100 ft, with derate warnings of up to 10% (80) and 15% (105) at a full 2" run.

When does the 105 make sense over the 80?

When the heat-loss calculation exceeds the 80's 71 MBH of DOE output on a design day. Below that, the 80's lower 16 MBH low fire tracks light loads better.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate