A flue damper is a motorized blade in the vent connector of an atmospheric boiler that closes when the burner is off to stop heat escaping up the chimney. This page explains how it works, how it fails, and what a licensed technician checks.
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Safety first
A flue damper sits in the path that carries combustion gases out of the house, so a damper that sticks closed or a control that loses sync can create a carbon-monoxide hazard. If a CO alarm sounds, leave the building with everyone inside and call 911 from outside. If you smell gas, leave and call FortisBC at 1-800-663-9911 or 911 from outside.
Never disable a flue damper, tape it open, or force the blade by hand to make a boiler run. The damper must be proven open before the burner fires, and the control that proves it is part of the appliance's safety system.
In British Columbia, servicing a flue damper and the venting it controls is licensed gas work under Technical Safety BC. Homeowners should observe the damper's position indicator from outside the jacket and call for service when it behaves abnormally.
What it does in a gas boiler
An atmospheric boiler draws combustion air through a draft hood and sends flue gases up a chimney. When the burner is off, that open path lets heated room air escape up the flue all winter. The flue damper, also called a vent damper, is a motorized blade installed in the vent connector that closes when the burner is off and opens before the burner fires.
The sequence is interlocked. Crown's Bermuda manual describes it: with the boiler energized and no call for heat, the damper closes; on a call for heat, voltage is applied to the damper and it opens; only when its end switch makes does the circuit continue through the safety switches to the ignition module. Dunkirk's WPSB manual describes the same operation and notes that the boiler is equipped with a factory-wired harness that plugs into the damper, and that the damper must be connected for the boiler to operate.
Dampers are also used in commercial common-vent arrangements. Viessmann's Vitocrossal 200 CM2 service instructions describe a motorized flue damper for common vent systems, wired to the burner control through a dedicated cable and configured in the control's service menu. Condensing boilers with sealed, dedicated venting do not use a flue damper; their venting is part of a sealed combustion system.
How it fails
The most common failures are mechanical and electrical. The operator motor can burn out, the end switch can fail so the control never sees the damper open, the blade can stick on corrosion or debris, and the linkage can jam. A damper that never opens leaves the boiler unable to fire; a damper that never closes wastes heat and lets the chimney cool, which can worsen draft.
A damper stuck partly open or closed is the dangerous case. If the blade does not reach its proven-open position, combustion gases can spill instead of venting, and the boiler may still run if the safety chain is compromised. That is why the control, the end switch and the damper are treated as one safety assembly.
Dunkirk's manual includes specific cautions: the damper blade on a furnished damper has a small hole that must be plugged on boilers with intermittent ignition, the damper must never be turned open manually or the motor will be damaged, and a hold-open switch exists for service use only. These details matter because field modifications to dampers are a recurring source of unsafe operation.
Safe things to check
The damper's position indicator is often visible through or beside the jacket. Dunkirk's manual tells homeowners that when the boiler is off the indicator should point to closed, and that when the thermostat calls, it should move to open and return to closed when the call ends. If the indicator does not move, note that and call for service.
Do not reach into the vent connector, do not turn the blade by hand, and do not use the hold-open switch to run the boiler through a fault. If a CO alarm sounds, leave the building and call 911 from outside; if you smell gas, leave and call FortisBC.
Keep the boiler room clear, make sure combustion-air openings are unobstructed, and have the damper inspected during annual servicing, as Dunkirk's manual recommends for the damper and all flue-product-carrying areas of the appliance.
What a licensed technician will check
A technician verifies the damper through a complete cycle: closed at rest, open and proven on a call for heat, and closed again when the call ends. They check the operator, the end switch, the wiring harness and the blade for freedom of movement and corrosion, and they confirm that the control is configured for the damper where the installation uses one. Viessmann's CM2 instructions, for example, include a service-menu setting for integrating the motorized flue damper and a fault code that points the technician to the damper and the flue gas path.
After any damper work the technician confirms draft and combustion with an analyser, because a damper that is out of position changes how the appliance vents. Where a damper has failed, it is replaced with the correct assembly for the boiler rather than repaired with field modifications.
If your boiler will not fire and the damper indicator never moves, or if the damper stays open after the burner stops, call ROMA Heating & Cooling for a venting and controls check.
Frequently asked questions
Can I open the flue damper by hand to get heat?
No. Forcing the blade can damage the operator, and the damper must be proven open by its own end switch before the burner fires. A damper fault is a service call, not something to override.
Why does my damper stay open after the boiler shuts off?
A damper that fails to close usually has a stuck blade, a failed operator or a control problem. It wastes heat and can affect draft, so it should be checked rather than ignored.
Do modern condensing boilers have flue dampers?
No. Sealed condensing boilers vent through dedicated plastic pipe and control combustion with a fan and pressure switches. Flue dampers belong to atmospheric boilers with draft hoods and chimneys.
Book a consultation
A technician reviews your building and options. Requests are confirmed by ROMA.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Dunkirk WPSB series gas-fired water boiler — installation, operation & maintenance manual · PN 240013090 Rev. F · accessed September 9, 2026
- Viessmann Vitocrossal 200 CM2 (186–311) service instructions · accessed September 9, 2026
- Crown Bermuda 2 (BSIB) installation, operating & service manual · 113113-02 · accessed September 9, 2026
- FortisBC — Carbon monoxide safety · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.