Pilot assembly

A pilot assembly is the small burner, orifice, igniter and flame sensor that lights the main burner on older gas boilers. This page explains standing and intermittent pilots, how they fail, and what a licensed technician checks before repairing one.

Safety first

If you smell gas, leave the building and call FortisBC at 1-800-663-9911 or 911 from outside. Do not try to light a pilot, do not press the gas valve button, and do not use a flame to check for leaks. Leave first, then call from a safe place.

The pilot assembly sits on the gas side of the appliance and its flame proves that gas can be burned safely before the main valve opens. Never bypass, tape or block a pilot safety circuit, and never modify the pilot tubing or orifice.

In British Columbia, pilot and ignition work is licensed gas work under Technical Safety BC. Homeowners can observe and report, but cleaning a pilot orifice, adjusting a pilot flame or replacing an assembly is contractor work.

What it does in a gas boiler

A pilot assembly is a miniature burner that establishes a flame before the main burner is allowed to run. It includes the pilot burner itself, a small orifice that meters pilot gas, an ignition source and a flame-proving device. On a standing-pilot boiler the flame burns continuously; on an intermittent-pilot system the control lights it only when there is a call for heat. Dunkirk's DXL manual describes its boiler as using an intermittent electric ignition pilot system with a non-linting safety pilot, and its combination gas control includes the pilot components.

The sequence is a chain of proofs. Crown's Bermuda manual describes it: the ignition module starts a spark at the pilot and applies voltage across the pilot valve; once lit, the flame acts as a rectifier and a tiny DC current flows to the module; only when the module senses that current does it open the main valve. The pilot flame has to be right for this to work, and Crown specifies that its center flame envelop a portion of the sensing probe.

Modern condensing boilers have moved past pilots entirely. NTI's Trinity Tft manual states plainly that the boiler does not have a pilot and is equipped with an ignition device that automatically lights the burner, which is why pilot problems are mostly found on older atmospheric equipment today.

How it fails

The pilot orifice and ports clog first. Dust, rust and debris restrict the tiny opening, so the flame becomes small, yellow or lazy and no longer heats the sensing probe properly. Slant/Fin's Sentry troubleshooting lists a pilot flame that is too low and clogged pilot ports or pilot orifices among the causes of delayed ignition, and the fix is cleaning and adjustment by a technician.

Ignition parts wear as well. A spark electrode can crack or its gap can drift; the ceramic insulator can fail; the flame sensor can become coated; and the pilot tubing or fittings can develop leaks. Crown's troubleshooting chart lists a defective pilot assembly among the possible causes when a boiler will not fire.

A pilot that will not stay lit is a safety message, not an inconvenience. It means the flame-proving circuit is not satisfied, and the correct response is diagnosis. Repeated manual lighting attempts can put unburned gas into the combustion chamber.

Safe things to check

Note whether the pilot lights at all, whether it stays lit after the control's trial period, and whether the main burner follows. If the boiler has an error display, write down the text or code. Mention any recent gas work, power outage or flooding near the boiler.

Do not remove the pilot assembly, do not clean the orifice with a pin or wire, and do not adjust the pilot screw. If you smell gas, leave and call FortisBC at 1-800-663-9911 or 911 from outside.

Keep the boiler area clear and free of stored items, and make sure the venting and combustion-air openings are unobstructed, since a pilot can also struggle when the appliance is starved for air.

What a licensed technician will check

A technician starts by confirming the pilot's behaviour and the control's sequence, then inspects the assembly: the pilot orifice and burner ports, the spark electrode and its gap, the flame sensor, and the pilot tubing and fittings. Where the assembly is fouled, it is cleaned following the manufacturer's procedure; where it is damaged, the pilot assembly is replaced as a unit with the correct orifice for the fuel.

The technician then verifies the flame envelope against the manual's specification, confirms the flame signal is strong enough for the control, and performs the safety shutdown test the manual describes. Crown's Bermuda start-up procedure, for example, requires disconnecting the ignition cable with the burners firing and confirming that both the pilot and main burners stop.

Pilot repairs are routine on older boilers and are finished with combustion verification. If your boiler's pilot will not hold or the burner will not follow it, call ROMA Heating & Cooling for a diagnosis rather than continuing to light it by hand.

Frequently asked questions

Should I relight my boiler's pilot myself?

Only if the appliance's own instructions show a homeowner lighting procedure and you smell no gas. If the pilot will not stay lit, stop and call for service. If you ever smell gas, leave the building and call FortisBC from outside.

What is the difference between a standing pilot and an intermittent pilot?

A standing pilot burns continuously and is proved by a thermocouple or thermopile. An intermittent pilot lights only when heat is called for and is proved electronically. Both are found on older boilers; modern condensing boilers have no pilot.

Can a dirty pilot cause carbon monoxide?

A pilot itself is small, but the conditions that foul a pilot, such as poor combustion air or a blocked flue, can also disturb main-burner combustion. That is why pilot problems are checked as part of the whole appliance, with combustion analysis.