Problem
Boiler losing pressure
What it means when a sealed gas boiler keeps losing pressure between top-ups: how to take cold gauge readings, the leaks and component faults behind the loss, and when to call a licensed technician.
What is happening
A gas boiler in a Greater Vancouver home usually heats a sealed loop of water. The same water circulates through radiators or in-floor tubing day after day, and little is added or drained except during servicing. The loop carries a small positive pressure so air stays out and water reaches every emitter, and a gauge on or near the boiler shows that pressure. The reading moves with temperature: water expands when heated, so the number climbs while the boiler runs and settles back down once the system cools.
When a boiler is losing pressure, the cold reading keeps falling between visits or the system needs regular topping up. A slow drop over several months is a different situation from a drop overnight, and the pace is one of the first clues a technician uses. A single low reading is not a diagnosis; two cold readings taken days apart, plus a note of how often you top up, describe the problem far better.
Safe things to check at home
Let the system sit unused for a few hours, then read the pressure gauge twice over several days and write both numbers down. Most residential boilers are set up to rest near 12 to 15 psi, roughly 80 to 105 kPa, when cold, but the correct figure for your boiler is the one in its own manual; brands and installations differ, so do not copy a neighbour's setting.
Look, without touching anything, for visible water: under the boiler cabinet, around pump and valve joints, at radiator valves, and on the floor near the boiler. Check whether the small discharge tube from the pressure-relief valve is dripping. If the display is showing an alert, write down the exact wording or code and look it up on this site's brand error-code pages. A code is not a diagnosis, but it is information a technician can act on.
Common causes
The most straightforward cause is a leak somewhere in the loop: a dripping valve or fitting, a corroded radiator connection, or piping that is failing where you cannot see it. BC homes with in-floor loops, slab runs and wall or ceiling piping can hide small leaks for a long time while the fill water slowly replaces what is lost.
Other faults lose water without leaving an obvious puddle. An expansion tank that has lost its air charge cannot absorb the water's expansion, so pressure can climb to the relief-valve setting when the system is hot; if that valve passes, water is discharged and the system reads low once cold. A fill valve that is not doing its job leaves the system low after any loss. In combination boilers an internal leak can let system water escape through the condensate or drain path, which is harder to spot from outside the casing.
A pressure log a technician can actually use
One gauge reading rarely explains a pressure drop, but a short written log usually does. Take the reading only when the system is cold, ideally first thing in the morning before the heating has run, and write down the number and the date. Repeat it over several days rather than several hours, and add two more notes each time: how much water you had to add, if any, and whether the gauge rose as usual while the boiler ran and settled back when it stopped. The difference between the cold and running readings is the expansion behaviour, and the pace of the cold drop is the loss.
If the system has an automatic fill valve, note whether the boiler seems to be quietly topping itself up, because a fill side that keeps feeding can hold the gauge up while the loop is still losing water. A log that shows a steady cold reading alongside a top-up every few days, or a relief-valve discharge tube that stays wet, tells a technician that the loss and the overpressure may be the same story. Write down any alert on the display too and look the code up on this site's brand error-code pages, since low-water protection on some controls produces a fault of its own.
Why constant top-ups work against the boiler
Top-up water restores the number on the gauge, but the boiler's own installation manual explains why it is not a neutral act. One manufacturer's manual instructs that all system leaks be eliminated because the continual introduction of fresh makeup water will reduce boiler life: minerals can build up in the heat exchanger, reduce heat transfer, overheat the exchanger and eventually cause it to fail. The same manual notes the system may carry residual substances that affect water chemistry, and calls for the water's pH and chlorine to be verified within an acceptable range. A sealed heating loop is designed to hold the same water for years, with a sealed, pressurized expansion tank absorbing expansion instead of letting the system discharge water and draw fresh water in.
Every top-up breaks that seal a little and adds dissolved air, which is why a slow leak so often travels with radiators that need bleeding. The practical conclusion is simple: a boiler that needs filling more than once or twice in a heating season is telling you there is a loss to find, not a chore to repeat. Technical Safety BC's annual servicing bulletin lists the expansion tank and the water pressure and temperature set points among the items a technician is expected to check, which is exactly where a homeowner's pressure log leads the diagnosis.
Reading the gauge: pressure is meant to move
A sealed heating loop is not meant to hold one fixed number. The water in it expands as it heats and contracts as it cools, so the gauge climbs while the boiler runs and settles back when the system is idle. The reading that matters is the cold one, taken before the heating has run for the day, and it should sit near the fill pressure the boiler's own installation manual specifies. Manufacturer manuals commonly describe a residential fill around 12 psi or higher, but the figure that counts belongs to the appliance in your home, not to a neighbour's boiler or a rule of thumb.
The way the two readings move together is a clue in itself. A cold reading near the manual's figure that rises by a modest amount when the system is hot is normal expansion. A cold reading that keeps sliding down over days or weeks is a loss. A hot reading that climbs unusually high, especially if the relief valve's discharge tube is wet, points instead at the expansion tank and the system's ability to absorb expansion. Writing down the cold number, the hot number and the interval between them turns a vague worry into a pattern a technician can read.
Natural Resources Canada describes the modern hydronic system as a sealed, pressurized loop with an expansion tank near the boiler, in place of the open tank older gravity systems used. That design is the reason a healthy boiler can sit for months without being touched, and why regular filling is a signal rather than a maintenance routine.
The expansion tank, and why it decides both readings
A sealed loop needs somewhere for water to go when it expands. The expansion tank provides it: a steel vessel holding a cushion of air or nitrogen, separated from the system water by a bladder or diaphragm. As the water heats and grows in volume, it compresses that cushion instead of raising the pressure past the relief valve's setting. When the water cools, the cushion pushes the water back and the gauge returns to its resting figure.
A tank that has lost its air charge, or whose bladder has failed so the vessel fills with water, can no longer absorb anything. The system then behaves as if it had no expansion space at all: pressure rises sharply while the boiler runs, the relief valve may open and discharge water, and the loop is short of water once it cools. The homeowner sees a low cold reading, tops the system up, and restores the gauge while hiding the cause. That is how a boiler can lose pressure and drip from its relief line without a single leaking fitting in the house.
Technical Safety BC's annual servicing bulletin lists the expansion tank and the water pressure and temperature set points together among the items a technician checks on a gas boiler, because they work as one system. A failed tank is also one of the few pressure problems that can be confirmed without opening a wall, since its air charge is measured directly at the tank's valve.
Where a hidden leak goes
When the expansion tank is sound and the cold reading still falls, water is leaving the loop. Some losses are easy to see: a weeping radiator valve, a stained joint under the boiler, a puddle that returns after it is wiped up. Others are not. In-floor radiant tubing cast into a concrete slab, piping run through finished walls and ceilings, and long buried runs between a mechanical room and a distant zone can weep slowly for months before anything shows. The water may surface far from the leak, evaporate from a warm slab, or follow a pipe and appear as a stain on a lower ceiling.
Greater Vancouver homes have several versions of this. Post-war houses with original steel piping and cast-iron radiators corrode from the inside, and every top-up adds fresh oxygenated water that feeds the process. Homes partway through a renovation can develop a leak behind new drywall. Because the loop is under pressure, even a very small opening can lose a surprising volume of water over a season.
Indirect signs are worth noting alongside the gauge: a musty smell in a basement or crawl space, mineral staining on drywall or framing, a warm patch on a floor, a fill valve that seems to run on its own, or radiators that need bleeding again soon after. None of these proves a leak, but together with a falling cold reading they tell a technician where to look first.
Slow, seasonal or rapid: what the pace tells you
The speed of the drop narrows the cause before any tool comes out. A reading that falls by a small amount across an entire heating season often comes from tiny weep points, dissolved air leaving the system after a drain-and-refill, or the normal settling of a newly filled loop. A drop that repeats within days points to a real loss that should be traced.
A reading that falls overnight, or that only falls while the system is hot, tells a different story. A cold reading that keeps sliding down while the boiler runs and climbs when it stops points at the expansion tank and the system's ability to absorb expansion, or at a relief valve that is passing water. The cold reading and the running reading should be logged together, because their relationship is as informative as either number alone.
A single drop after a repair, a zone purge or a radiator change is expected: opening the loop lets water out, and refilling to the cold figure the manual specifies is part of that work. It is a drop that continues after the system has been refilled correctly that deserves attention.
The fill valve and the relief valve
Two fittings decide what the gauge reads, and both are worth understanding. The fill valve, often a pressure-reducing valve on the cold-water connection, sets the resting pressure of the loop. A fill side that keeps feeding can hold the gauge up while water is still leaving the system, which is why a system with an automatic fill can lose water for a long time without the owner noticing.
The pressure-relief valve is the safety outlet. It opens at its rated setting to protect the loop and its components from overpressure, and it discharges through a tube to a safe location. If that tube is wet, dripping or stained, the system is reaching relief pressure and discharging water; once the loop cools, the gauge reads low and the owner tops it up, which hides the cause. A relief valve that drips at normal pressure, or that has been opened and does not reseat, is a repair.
Neither valve should be adjusted by a homeowner. The relief valve's setting is a safety rating, and altering it or blocking its discharge defeats the protection it provides. A technician checks both against the boiler's manual as part of a pressure diagnosis.
The correct cold pressure is in your boiler's manual, not online
There is no single pressure that suits every gas boiler, and the figure a neighbour's system runs at is not a specification for yours. Each appliance is commissioned to a cold fill pressure its own installation and operation manual states, and the same manual also gives the pressure the system should hold and the range the control expects. A boiler filled to one figure and one commissioned higher can both be correct, which is why the number to trust is the one printed for your model rather than a figure copied from another house or a general rule of thumb.
The manual's unit matters too. Some gauges and displays read in psi, others in bar or kPa, and a reading only means something when it is compared in the same unit the manual uses. The analogue gauge on the boiler, the digital readout on the control and a separate pressure gauge can also disagree slightly, so the reading a technician acts on is the one taken at the same point and in the same unit the manual specifies. A gauge that has drifted is itself a finding, not a reason to change the fill pressure.
The distinction that matters most for a system that keeps losing pressure is between one correct fill and a topping-up habit. Refilling a loop that was drained for a repair, or bringing a cold system back to its documented figure after a radiator change, is part of that work. Adding water every week to hold the gauge up is a different act: it replaces the water that is leaving, hides the loss, and introduces fresh oxygen and minerals into a loop designed to keep the same water for years. Manufacturer guidance warns that continual makeup water shortens boiler life because minerals accumulate in the heat exchanger, which is why repeated filling is treated on this site as a symptom to trace rather than a routine to repeat.
Where a boiler has a documented user procedure for adding water, follow that procedure exactly and use only the method and the pressure the manual states; where it does not, the correct move is to arrange the repair rather than improvise. Nothing about topping up a sealed loop is a reason to open the boiler casing or touch a gas component, and a gas smell at any point means leaving the building and calling the FortisBC emergency line at 1-800-663-9911 or 911 from outside.
A combi boiler that keeps losing pressure
A combination boiler holds two circuits in one cabinet: the sealed heating loop that serves the radiators or in-floor tubing, and the domestic hot-water path that heats tap water on demand. The pressure gauge on the front of a combi reads the heating loop, so a falling gauge means that loop is losing water, exactly as it would on a heating-only boiler. What is different on a combi is that some of the places water can leave are inside the appliance rather than on the visible pipework.
An internal leak can send system water out through the condensate or drain path, where it looks like the boiler's normal condensing water rather than a puddle, so the first sign is a cold reading that keeps sliding down with nothing wet on the floor. A component on the domestic side that has failed can also let the two circuits interact, which shows up as pressure behaviour rather than as a visible drip. These are faults a technician confirms by isolating and testing the appliance, not by adding water and watching the gauge.
The other combi-specific item is the filling arrangement. A combi is normally filled through a built-in or external filling loop that connects the mains supply to the heating loop, and a loop that is left open or that passes when it should be closed lets mains water keep entering. That raises the pressure rather than lowering it, and it can push the system to its relief-valve setting once the water heats and expands. The loop is meant to be closed after filling, and a fill side that will not shut is a repair rather than a setting.
For a homeowner the useful evidence is the same as for any pressure loss, with one addition: note whether the gauge also rises more than usual when the boiler is hot, because that points at the fill or expansion side rather than at a plain leak. Record the cold reading, how often the system needs water, and whether the condensate drain seems to run more than it should. Those notes let a technician tell a loop leak from an internal one before the visit begins. Call ROMA Heating & Cooling at 778-909-5731 during business hours with the pattern.
Pressure loss in a home with in-floor radiant heating
A home with in-floor radiant heating holds far more water than one with a few radiators, and it distributes that water through a manifold, one small loop per room or zone. The same sealed-loop rules apply, but the places water can leave are different. A manifold that weeps at a connection, an actuator or fitting that was never fully tight, or the tubing itself can lose water slowly where nothing is visible on a finished floor.
A slab leak is the hardest version to find, because the tubing is cast into concrete and the water may never surface. A cold reading that keeps falling with no wet spot, in a home with in-floor heat, points a technician toward isolating the loops at the manifold and testing them one at a time. That is why manifold access matters: a manifold boxed behind a finished panel turns a straightforward test into a search. Natural Resources Canada describes the modern hydronic system as a sealed, pressurized loop with an expansion tank near the boiler, and in-floor loops are part of that loop rather than a separate system.
Radiant systems also collect air at their high points, and a loop that has just been filled or purged often settles as that air works out. Manufacturer guidance places air vents and bleeders so the system can be purged and notes that air removal works better when devices sit high in the system. A drop that follows a manifold purge and then stops is settling; a drop that continues afterwards is a loss. ROMA Heating & Cooling services hydronic heating across Greater Vancouver, so call 778-909-5731 with the cold readings and the pace of the drop.
A new boiler, or a recent repair: when a drop is expected
A pressure drop is not automatically a fault. When a system is drained to replace a boiler, add a zone or change a radiator, the fresh water that refills it carries dissolved air, and as that air works its way out through the system's vents the cold reading can settle down over the first days and weeks. A newly installed boiler is commissioned to the cold fill pressure its own manual states, and a small settling drop after that is part of a new fill rather than evidence of a leak.
What separates expected settling from a problem is the trend, not a single number. A reading that drifts down a little and then holds is normal; one that keeps falling after the system has been brought to its documented cold figure, or that needs water again within days, is a loss. That is why the cold-reading log matters most in the weeks after any work on the loop: it shows whether the pressure is finding a level or continuing to leave.
A drop can also follow a repair for a simpler reason: a fitting that was disturbed may weep, or a valve may not have been left fully closed. Those are worth reporting to whoever did the work rather than topping up and hoping. And where a system was refilled with fresh water, the manufacturer guidance that continual makeup water shortens boiler life is the reason a technician checks the fill pressure and the water condition rather than treating the refill as finished work.
Cold weather, freeze protection and the pressure gauge
Greater Vancouver's cold snaps are short, but they raise two pressure questions at once. The first is ordinary: a sealed loop reads lowest when the water is coldest, so a system that was already marginal can look lower on a cold morning. The second is serious: water in piping that runs through an unheated space, such as a garage, a crawlspace, an attic or an exterior wall, can freeze, and a frozen section stops flow and can split a pipe.
Freezing is a property risk rather than a gauge reading, and it is most likely in zones that were added through cold spaces or in homes where the boiler itself sits in an unheated garage. The signs are a zone that stops heating while the boiler still runs, or a pressure drop that follows a hard freeze. Nothing about that is a reason to open the loop or to thaw a pipe with a torch; the safe move is to protect the building and call for service.
The routine answer is prevention. A boiler service before the heating season checks the water pressure and temperature set points and the expansion tank, which is where a marginal system is caught before the first freeze, and it is also the visit where a technician can note any piping that runs through an unheated space. If a zone has already frozen, use the emergency service line. Call ROMA Heating & Cooling at 778-909-5731 during business hours with what you have seen.
Preventing the drop: what an annual service covers
Most pressure problems are easier to prevent than to chase. Technical Safety BC's annual servicing bulletin lists the expansion tank and the water pressure and temperature set points among the items a technician is expected to check on a gas boiler, alongside combustion and venting, which is exactly where a slow loss is caught early. A tank that has lost its air charge is often found at a service before it has discharged enough water to be noticed.
Water quality belongs in the same schedule. A sealed loop is meant to hold the same water for years, so the inhibitor level, the pH and the general condition of the water are checked and corrected rather than repeatedly diluted with fresh makeup water. Manufacturer guidance is explicit that continual fresh water shortens boiler life because minerals accumulate in the heat exchanger.
For a homeowner, the habit that helps most is the cold-reading log. A few dated numbers, plus a note of how often the system needed topping up, let a technician see the trend instead of a single snapshot, and often decide whether a visit is routine or urgent.
When a pressure drop is urgent
A slow pressure loss is a maintenance problem; a rapid one can be a safety or property problem. Call the emergency service line when the boiler has shut down on low-water protection and the home is without heat, when water is escaping where it can reach electrical equipment or finished surfaces, or when a Greater Vancouver cold snap threatens a zone whose piping could freeze.
If you can see an active leak, keep electrical items clear of the water, place a container under the drip if it is safe to do so, and leave the boiler running only if nothing suggests it is unsafe. If you smell gas, leave the building and call FortisBC at 1-800-663-9911 or 911 from outside before anything else. Otherwise, call ROMA Heating & Cooling at 778-909-5731 with the pace of the drop and your cold readings.
Describing the pattern, whole-system or one zone, hot-only or always, slow or rapid, is most of the diagnosis. It tells the technician whether to expect a leaking fitting, an expansion-tank fault or a hidden slab leak before the van leaves the shop.
When to call
Call when topping up has become more than an occasional seasonal habit, when you can see a leak you cannot stop, or when the pressure is dropping over days rather than weeks. A small hidden leak may be wetting framing, drywall or the insulation under a slab, and the cost of drying and repair tends to grow the longer it runs.
If you have found a visible drip, place a container under it, keep electrical items clear of the water, and leave the boiler running only if it is safe to do so. Call ROMA Heating & Cooling at 778-909-5731 during business hours and describe the pace of the drop and your cold readings; that description helps the technician bring the right parts.
What a licensed technician will do
A technician starts from a cold reading, brings the system up to the pressure the boiler's manual specifies, and watches how it holds. If the drop resumes, the loop is isolated zone by zone to find a hidden leak, the pressure-relief valve and its discharge path are checked, the fill assembly is tested, and the expansion tank's air charge is verified with a gauge.
Repairs can range from tightening a fitting or replacing a valve to re-charging or replacing the expansion tank and repairing piping. When a leak is inside the boiler's heat exchanger, the honest conversation is repair versus replacement. Gas work in British Columbia is regulated by Technical Safety BC, which issues permits for gas installations and repairs; ROMA's licensed gas contractors carry out this work under the permit system.
Frequently asked questions
Is it normal for boiler pressure to drop slowly over a season?
A very slow drop can come from tiny weep points, air leaving the system or seasonal temperature swings. Track your cold readings and how often you top up; if the pace accelerates, have the loss traced.
How often should a homeowner top up a boiler?
If you are topping up more than once or twice in a heating season, there is probably a loss that should be found rather than continuously fed with fresh water.
Can a boiler lose pressure without any visible leak?
Yes. A relief valve passing at pressure, an expansion tank that has lost its charge, trapped air and internal combination-boiler leaks can all drop the cold reading with no puddle in sight.
The pressure dropped after a repair or drain-down. Is that normal?
Often yes. Opening the loop for a repair, a zone purge or a radiator change lets water out, and refilling to the correct cold pressure is part of that work. A drop that continues after the system has been refilled to its manual's figure is a different matter and should be traced.
Does adding water more often hurt the boiler?
It can. A sealed loop is meant to keep the same water, and manufacturer guidance warns that continual fresh makeup water shortens boiler life because minerals build up in the heat exchanger. Frequent top-ups should be treated as a symptom to investigate.
Why does boiler pressure rise when the heating is on and fall when it cools?
That movement is normal expansion. Water grows in volume as it heats, so the gauge climbs while the boiler runs and returns to its cold figure once the system rests, with the expansion tank absorbing the change. A cold reading that keeps falling over days or weeks is the part that is not normal and should be traced.
Can a failed expansion tank make a boiler lose pressure?
Yes. If the tank loses its air charge or becomes waterlogged it cannot absorb expansion, so pressure spikes when hot and the relief valve can discharge; the loop then reads low once cold. Technical Safety BC lists the expansion tank among the items checked at an annual service, and its charge is measured directly at the tank.
The pressure keeps dropping but I cannot see any water. What should I do?
Keep the cold-reading log, note any musty smell, staining or warm floor patches, and have the loop traced. Hidden leaks in slab, wall or ceiling piping are common in Greater Vancouver, and the longer one runs the more it can damage. Call ROMA Heating & Cooling at 778-909-5731 with the pace of the drop and your readings.
Can trapped air make a boiler lose pressure?
Air leaving the system through automatic vents can lower the reading slightly, and a loop that has just been refilled often settles as dissolved air works its way out. A drop that continues after the system has settled and been refilled to its manual's cold figure points to a real loss rather than air.
Should I keep topping up the boiler until it can be repaired?
Top up only enough to restore the cold pressure the boiler's manual specifies, and treat repeated filling as a symptom to investigate rather than a routine. Manufacturer guidance warns that continual fresh makeup water shortens boiler life, so a system needing regular top-ups should be traced.
Will a leaking pressure-relief valve lower my boiler pressure?
Yes. A relief valve that opens at overpressure, or one that does not reseat and drips, discharges water that is not replaced, so the cold reading falls. A wet or stained discharge tube is a strong clue and should be reported; the valve is checked and replaced by a licensed technician.
Why does my boiler need topping up every week?
Weekly top-ups point to a loss that should be found rather than fed. Common causes are a hidden leak in slab, wall or ceiling piping, an expansion tank that has lost its charge, or a relief valve passing water when the system is hot. A cold-reading log and the pace of the drop help a technician target the search.
What pressure should my gas boiler be when cold?
The correct cold fill pressure is the figure in your boiler's own installation and operation manual, not a number copied from another home. Manufacturer manuals commonly describe a residential fill around 12 psi or higher, but models and installations differ. Read the gauge cold, before the heating has run, and compare it in the unit the manual uses.
Can I top up my boiler pressure myself?
Only where your boiler's manual documents a user procedure for adding water, and only to the pressure it states. Follow that procedure exactly, close the filling loop afterwards and watch the reading. Repeated top-ups are a symptom of a loss, and manufacturer guidance warns that continual fresh makeup water shortens boiler life, so a system that keeps needing water should be traced rather than regularly filled.
Why does my combi boiler lose pressure with no visible leak?
A combi can lose heating-loop pressure through an internal leak that drains with the condensate rather than onto the floor, so the cold gauge falls with nothing wet in sight. A failed component on the domestic side can also let the two circuits interact. Both are confirmed by isolating and testing the appliance, not by adding water.
My pressure gauge reads bar or kPa, not psi. Is that a problem?
No. Gauges and displays use different units, and psi, bar and kPa are all normal. The reading only means something when it is compared in the same unit your boiler's manual uses, and a separate gauge may read slightly differently from the one on the control. The manual's figure is the reference.
My new boiler keeps losing pressure. Is that normal?
A small settling drop after a new fill can be normal, because the fresh water carries dissolved air that works its way out and the reading finds a level. A reading that keeps falling after the system is at its documented cold figure, or that needs water again within days, is a loss to trace rather than something to keep topping up.
Why does my boiler pressure drop more in cold weather?
A sealed loop reads lowest when the water is coldest, so a system that was already marginal can look lower on a cold morning. A drop that follows a hard freeze can also mean water in a run through an unheated space has frozen, which is a service call rather than a top-up.
Can a leak in an in-floor heating loop cause pressure loss?
Yes. Radiant tubing is often cast into a slab, so a weeping loop fitting or a slab leak can lower the cold reading with nothing visible on the floor. A technician isolates the loops at the manifold and tests them one at a time, which is why manifold access matters.
Does bleeding a radiator lower the boiler pressure?
Yes. Bleeding releases water and air from the loop, so the pressure falls a little and the system may need topping to its documented cold figure. If it keeps needing water after that, the loop has a loss to find rather than air to remove.
Talk to a boiler technician
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NCB-H Installation and Operation Manual — Navien · accessed September 7, 2026
- Natural Resources Canada — Heating with Gas (EnerGuide heating and cooling series) · M143-2/9-2012E-PDF · accessed September 15, 2026
- Natural Resources Canada — guide to maintaining your home heating and cooling system · accessed September 15, 2026
- Technical Safety BC — homeowner gas permits · accessed September 7, 2026
- Technical Safety BC — information bulletin: annual servicing for gas appliances (B-G5 071019 3, Revision 1, May 19, 2010) · B-G5 071019 3, Revision 1 · accessed September 15, 2026
- FortisBC — appliance maintenance and safety · accessed September 15, 2026
Facts checked September 15, 2026. Last updated September 15, 2026. Technical reviewer: not yet assigned.