Problem

No hot water

Why a gas boiler can stop delivering domestic hot water while the heating still works, the differences between combi and indirect-tank setups, and what to check before calling ROMA.

What is happening

Hot water in a boiler home comes from one of two arrangements. A combination boiler heats water on demand as it flows through an internal plate heat exchanger, while a heating-only boiler paired with an indirect tank stores hot water that the boiler reheats through a coil. The two designs fail differently, and knowing which one you have is the first step in describing the problem.

The key observation is whether the heating still works. If radiators and in-floor loops heat normally but the taps run cold, the fault is in the domestic-hot-water path. If nothing works, the boiler itself is the more likely problem. Also notice whether every tap is cold or only some, and whether the water is completely cold or just lukewarm.

Safe things to check at home

Read the boiler's display and note any alert text or code; on a combination boiler this can point straight at the domestic-hot-water circuit. Check the boiler's hot-water temperature setting if you know where it is, and confirm that no one has changed it recently.

For an indirect-tank system, check the tank's thermostat setting and its power supply if it has its own. Confirm that the flow from the tap is normal; a heavily restricted flow can be too low to trigger a combi boiler. If the manual that came with the boiler documents a user reset, you may reset once after a lockout, then watch whether hot water returns. A code is not a diagnosis, and the code pages for your brand on this site explain what each alert does and does not mean.

Common causes

On combination boilers the usual suspects are scale and debris inside the domestic plate heat exchanger, a failed flow sensor that never tells the boiler a tap is open, a diverter valve stuck between heating and hot-water modes, or a hot-water temperature sensor reading incorrectly. Incoming water is cold in winter, which can also expose an undersized or fouled exchanger.

On boiler-plus-tank systems the causes move to the tank side: a zone valve that will not open for the tank, a circulator that has failed, a thermostat or sensor fault, or the boiler's controls not giving the tank priority. With either design, an ignition or control fault that stops the burner will eventually kill the hot water as stored heat runs out, even if it first shows up as no heating.

Why a combi boiler stops making hot water

It helps to remember that a combination boiler has no tank of stored hot water. It stays off until it senses that someone has opened a tap, and then it fires and switches its output to an internal plate heat exchanger that warms the domestic water as it flows. Every part of that chain can break, and where it breaks decides whether the symptom is no hot water, lukewarm water or hot water that comes and goes.

If the boiler never fires when a tap opens, the call for hot water is not reaching the control. A flow sensor or turbine that no longer reports movement, an inlet filter or strainer clogged with debris, or simply a flow too low to trigger the boiler are the common reasons. A diverter valve stuck in the heating position has the opposite effect: the boiler fires, but it sends its heat to the radiators instead of the tap, so the rooms stay warm and the showers stay cold.

If the boiler fires but the water is only warm or lukewarm, the fault is usually in the transfer of heat rather than the call. Scale and debris coating the domestic plate heat exchanger insulate it, so the water passes too quickly to pick up enough heat. A domestic temperature sensor reading incorrectly can make the control aim for the wrong target, and a mixing or tempering valve that has drifted can blend the hot water back down before it reaches the tap.

A combi also loses hot water for reasons that have nothing to do with the domestic circuit. A lockout or blocking fault on the ignition, vent or condensate side stops the whole appliance, so no hot water is produced because the boiler is not running at all. That is why the display code, if there is one, is the first thing worth writing down.

Heating works but the taps stay cold

This is the signature combi fault, and it is genuinely useful evidence. If the radiators and in-floor loops heat normally, the boiler is firing, circulating and controlling temperature on the heating side, which clears a long list of appliance faults. The problem is confined to the domestic hot-water path: the flow sensor or turbine, the diverter valve, the domestic plate heat exchanger, the hot-water temperature sensor, the inlet filter, or a tempering valve.

It also tells the technician what to prepare for. A diverter valve or sensor is a parts repair, while a scaled plate exchanger is a cleaning or replacement job, and those are different visits. When you call, saying clearly that the heating works but the taps run cold saves the guessing that comes from a vague 'no hot water' description.

Cold inlet water and the limits of a combi

A combi heats water as it flows, so the temperature it can deliver depends on two things: how fast the water is moving and how cold it is when it arrives. In winter, municipal supply water in Greater Vancouver is much colder than in summer, so the same tap flow leaves the boiler with a smaller temperature rise to work with. A combi that performs acceptably in July can feel weak in January without anything having failed.

That limit shows up when demand piles up at once: two showers plus a dishwasher or a washing machine can ask for more hot water than a combi can heat in the moment, and the result is water that cools as each fixture competes for the same capacity. If that pattern is the everyday reality of the home rather than an occasional inconvenience, the honest answer may be a hot-water storage tank or a different system design rather than a repair, and that is a conversation worth having before the next failure.

If only one tap runs cold

Not every no-hot-water complaint is an appliance fault, and the fastest way to tell is to compare outlets. If the kitchen tap runs cold while the bathroom shower is hot, or one shower is cool while the rest of the home is fine, the combi is still producing hot water and the problem sits downstream of the boiler. On a combi the usual causes are fixture-side: a single-handle faucet or thermostatic shower cartridge that has failed or stuck, a mixing valve blending cold water into the hot side, or a long dead-leg of pipe that has to be run before hot water reaches the fixture.

The check is simple and safe. Run the affected tap on full hot for a minute or two and feel the pipe nearest the fixture, then do the same at an outlet that works. If the hot pipe at the affected fixture stays cold while a nearby tap runs hot, the appliance is delivering and the fault is local to that fixture or its branch. Note which outlets are affected and whether they share a bathroom or a wall, because that pattern tells a technician whether one cartridge or one branch is involved rather than the boiler.

No hot water after a power cut or a reset

A power interruption can leave a combi powered but not making hot water, and it is worth separating this from a genuine fault before booking a visit. When power returns, some controls need a short wait or a documented reset before they will fire again, and some return to standby until the next call for heat or hot water. A combi that worked before an outage and is silent afterwards may simply be waiting. Check the display, confirm the boiler's service switch and breaker are on, and open a hot tap fully to give the appliance a clear call; if it still does not respond, treat it as an ordinary no-hot-water fault rather than an outage quirk.

Clearing an alert produces the same picture for a different reason. A reset clears the message, not the condition that caused it, so a combi that fires briefly and stops again has told you the underlying fault is still there. Write down the exact alert text or code, and do not keep resetting: repeated ignition attempts add wear and some controls lengthen their lockout with every try. A combi that lost hot water at the same moment as a power cut may also have a diverter valve that has returned to its default position, which is a technician check rather than a homeowner one. If the tap stays cold after the switch, breaker and one allowed reset, call ROMA Heating & Cooling at 778-909-5731 with the display code and whether the heating still works.

No hot water after plumbing work, a water shut-off or a main repair

A combi boiler can lose its hot water immediately after the water supply has been shut off and turned back on, or after work on the mains or the home's plumbing, without anything in the appliance having failed. Closing and reopening a supply line stirs up sediment and lets air into the pipes, and a combination boiler's small internal water paths are sensitive to both. Debris can lodge in the inlet filter or strainer, and air pockets can disturb the flow the boiler needs before it will fire.

The first sign is often that the boiler no longer reacts to a tap. A combi stays off until its flow sensor reports enough water moving through the domestic side, so a restricted inlet filter or a sputtering, air-filled line can leave it waiting while the tap runs. Running the affected tap fully open for a minute or two may clear a small air pocket and let the boiler sense demand, and checking that the cold-water isolation valve to the boiler was fully reopened after the work is a safe and sensible step.

What is not sensible is opening the boiler to clean its filters or strainers. Those parts sit behind the casing on the domestic water connection, and the same visit that checks them also verifies the flow sensor and the rest of the domestic path. If running the taps and confirming the valve do not restore hot water, the fault should be diagnosed rather than worked on. If the water was off because of an emergency main repair, it is also worth flushing a cold tap first to clear discoloured water before drawing hot, so sediment is not pulled through the appliance.

This is also a moment to note what changed and when. Work on the mains, a plumbing repair, a shut-off for a renovation, or a utility interruption are all relevant history, and so is the first time the hot water failed after the water came back on. A technician who knows the water was recently off will check the inlet filter, the strainer and the flow sensor first, which is often the difference between one visit and two. Call ROMA Heating & Cooling at 778-909-5731 with the date of the work and whether the boiler fires at all on a hot tap.

No hot water in a rental or strata home: what a tenant can check and who arranges the repair

A renter or strata owner facing no hot water has the same safe checks available as any homeowner, but a different route to the repair. The observations that help most do not require opening anything: whether the heating still works, whether the boiler fires when a hot tap is opened, whether every tap is affected or only one, whether the water is cold or lukewarm, and the exact alert text or code on the display. Those notes are what a landlord, a property manager or a technician will ask for first, and writing them down saves a visit.

In a strata building, the hot water may come from a boiler serving the whole building or from an appliance inside the unit, and the two paths are managed differently. A building-wide loss of hot water is a common-property matter for the strata corporation or its manager, while an in-suite combi is usually the owner's or landlord's responsibility. The building manager or council can say which system serves the unit, and that answer decides who arranges the repair. A renter should report the problem to the landlord or manager in writing rather than arranging work independently, because the gas appliance and its repair are the property owner's responsibility.

There is a documented obligation behind that division. Technical Safety BC states that landlords and property managers must have all gas appliances inspected and serviced annually by a licensed contractor and keep the service records on file, so a rental with no hot water is not only a comfort problem; it may point to an appliance that has missed its service. For a strata, the same annual servicing expectation applies to the building's gas appliances, and records kept by the manager show when the boiler was last checked.

What a tenant should not do is attempt the repair. Gas work in British Columbia is regulated by Technical Safety BC, and a gas appliance is serviced and repaired by a licensed contractor under the permit system, not by an occupant or a general handyperson. The safe role for a tenant is to observe, record and report: note the display code, whether the heating works, and which taps are affected, then pass those notes to whoever arranges the repair. If a gas smell or a carbon-monoxide alarm is involved, that overrides everything: leave the building and call FortisBC's emergency line at 1-800-663-9911 or 911 from outside before reporting anything else. ROMA Heating & Cooling serves Greater Vancouver homes, including rentals and strata buildings, and can attend once the owner or manager has arranged the visit.

When the heating and a hot tap call at the same time

A combination boiler cannot heat the home and the tap at full output at the same moment, and its controls handle that with a priority rule rather than a fault. When a hot tap opens, the appliance normally gives the domestic side priority: it moves its output to the internal plate heat exchanger and pauses or limits the heating circuit until the tap closes. That is why radiators can cool slightly while a long shower runs, and why the heating usually resumes when the tap is shut.

The diverter valve is the part that makes the switch, and a valve that is stuck or slow changes the symptom in a recognisable way. Stuck toward heating, it sends the boiler's heat to the radiators while the tap runs cold, so the rooms stay warm and the showers do not. Stuck toward hot water, it can leave the heating short while the tap works. A valve that moves but does not seat cleanly can give water that is hot, then cool, then hot again as the appliance hunts for a position.

What is normal and what is a fault are worth separating. Heating that pauses while a tap is open is normal on a combi and is described in the manufacturer's manual for the appliance. Hot water that never reaches temperature no matter how long the tap runs is not normal, and neither is a tap that stays cold while the boiler fires. Note whether the display shows a hot-water demand symbol when the tap is open, whether the heating recovers afterwards, and whether the water is cold throughout or only at the start; those three observations tell a technician whether the diverter is the problem or the appliance is working as designed.

Lukewarm water rather than cold

No hot water and not-hot-enough water are different complaints that point at different parts. When a combi delivers water that is warm or lukewarm, the appliance is usually firing and transferring some heat, so the fault is in how much heat reaches the water rather than whether the boiler runs. That distinction is the first thing to note, because a completely cold tap sends a technician to the flow sensor and the call for heat, while lukewarm water sends them to the heat transfer and the controls that set the target temperature.

A scaled or fouled plate heat exchanger is the most common cause. Scale and debris coat the metal, insulate it, and leave the water less time to pick up heat as it passes, so the temperature at the tap falls even though the burner is running. A domestic temperature sensor reading incorrectly makes the control aim at the wrong target, and a mixing or tempering valve that has drifted blends cold water back into the hot before it reaches the fixture. Cold incoming water in winter makes every one of these worse, because the appliance has a smaller temperature rise to work with.

There is also a setting worth knowing. Many combis let the household set the domestic hot-water temperature, and a setting that has been turned down, or changed by accident, produces lukewarm water with no fault at all. Check the setting if you know where it is and whether anyone changed it, then leave the rest to a technician. Measuring the actual temperature and flow at a tap is how the fault is separated from the setting, and that is done with instruments rather than by feel.

No hot water after a service, a descale or a repair

Hot water that fails in the hours or days after a service, a descale or a repair is a common and understandable event, and its timing points at the work rather than at sudden wear. Opening the domestic side lets air into the pipework and can stir up sediment, and a combi needs a steady minimum flow before it will fire. Air or loosened debris at the inlet filter or strainer can leave the appliance waiting while the tap runs, which looks exactly like a failed flow sensor.

The first checks are safe and simple: confirm that the cold-water isolation valve to the boiler was fully reopened after the work, run the affected hot tap fully open for a minute or two to clear a small air pocket, and read the display for any code. A setting that was changed during the visit, such as the domestic temperature, is also worth confirming. None of these require opening the casing, and together they resolve a share of post-service no-hot-water calls.

What is not a homeowner step is opening the appliance to clean the filter or reset a sensor. Those parts sit behind the casing on the domestic water connection, and the same visit that checks them also verifies the flow sensor and the rest of the domestic path. When hot water fails immediately after work, the first call belongs to whoever did the work: a return visit under the same job is normal practice and cheaper than a fresh diagnosis. Have ready what was done, when, whether the boiler fires at all on a hot tap, and whether the heating still works. Gas-side work in British Columbia is carried out by licensed contractors under Technical Safety BC's permit system, and the domestic side of a combi is serviced by the same trade. Call ROMA Heating & Cooling at 778-909-5731 with the timing and the display code.

What to note before you call

Four observations turn a vague complaint into a diagnosis: whether the heating still works, whether the boiler fires when a hot-water tap is opened, whether every tap is affected or only one, and whether the water is completely cold or merely lukewarm. Add the exact display code or message if there is one, and mention any recent work such as a drain-down, a repair or a change to the boiler's settings.

With those notes, a technician can tell whether the visit is a flow-sensor or diverter replacement, a descale of the domestic exchanger, or an appliance fault that has stopped the boiler entirely. Without them, the first part of the visit is spent rediscovering what the homeowner already knew.

When to call

Call when hot water has stopped entirely, when it returns only briefly after a reset, or when it has become lukewarm and stays that way. For a household with children, seniors or tenants, no hot water is an urgent comfort and hygiene problem even outside the heating season.

Before calling, write down the display code if there is one and whether the heating still works. Call ROMA Heating & Cooling at 778-909-5731 during business hours; a combi boiler with a fouled domestic exchanger and an indirect-tank system with a dead circulator often need quite different visits.

What a licensed technician will do

A technician verifies whether the appliance is firing for hot-water calls, then measures what the system actually delivers: flow rate from the tap, temperature rise across the domestic exchanger, and the resistance of the relevant sensors compared with the manual's table. Diverter-valve travel and flow-sensor response are tested under load rather than assumed.

On a combi boiler the fix is often a flush or descale of the domestic heat exchanger, a new sensor or valve, or occasionally replacement of a scaled exchanger. On a tank system the technician confirms the zone call, tests the circulator and checks the tank's controls and sensor, replacing whatever failed and verifying the recovery time afterward. Work that touches gas components is done by licensed contractors under Technical Safety BC permits.

Frequently asked questions

Heating works but there is no hot water. Is that normal?

It is a useful clue rather than a condition to accept. On combi boilers it usually means a fault in the domestic-hot-water path; on tank systems the tank's zone valve, circulator or controls are often the cause.

Why is my combi boiler's hot water only lukewarm?

Lukewarm output with normal flow often points to a scaled or fouled domestic heat exchanger, a misbehaving diverter valve or a sensor reading incorrectly. Cold incoming water in winter makes all of these worse.

Should I run the tap to force the boiler to heat water?

Running a tap can confirm whether the boiler fires for a hot-water call, but it will not clear a real fault. Note what you see and call rather than repeating the test.

My combi boiler fires but the water stays cold. What is wrong?

If the boiler lights on a hot-water call but the tap runs cold, the heat is going to the heating loop or is not transferring: a diverter valve stuck in the heating position, a scaled or blocked plate heat exchanger, or a domestic temperature sensor reading incorrectly are the usual causes.

Why does my combi shut off when I open a tap slowly?

A combi needs a minimum flow to sense that a tap is open and to fire. Turn the tap fully on to test it, and if the boiler still will not fire, the flow sensor, inlet filter or activation setting is the place a technician looks.

Can a combi boiler run out of hot water?

It has no stored water, so it can be outpaced rather than emptied. If several fixtures run at once, or the incoming water is very cold in winter, the temperature can fall because demand exceeds what the boiler can heat at that moment.

Heating works but there is no hot water at all. Could the boiler still be faulty?

Yes, but the fault is in the domestic path rather than the appliance as a whole. The heating side proves the boiler fires and circulates, so the technician focuses on the flow sensor, diverter valve, plate exchanger, domestic sensor and inlet filter.

Only one tap has no hot water but the others are fine. Is the boiler at fault?

Usually not. A combi that heats the other taps is still working, so a single cold outlet points to that fixture's mixing cartridge, a stuck thermostatic valve or a long dead-leg of pipe. Compare the hot pipe at the affected fixture with one that works before assuming the boiler failed.

Why is there no hot water right after a power outage?

Some controls need a short wait or a documented reset after power returns, and some stay in standby until the next call. Confirm the service switch and breaker, read the display, then open a hot tap fully. If it still will not fire, treat it as a normal no-hot-water fault and call.

I reset the boiler, got hot water back, then it stopped again. What now?

A reset clears the message, not the cause. If hot water returns briefly and then fails, the fault is still present, and repeated resets can add wear and lengthen some lockouts. Write down the exact code or message and book a diagnosis.

Why did I lose hot water after the water was shut off and turned back on?

Reopening a supply line stirs up sediment and lets air into the pipes. A combi needs a minimum flow before it will fire, so air or debris in the inlet filter can leave it waiting while the tap runs. Run the tap fully open, confirm the boiler's cold feed valve is fully open, and call if it does not recover.

Can I flush the combi boiler's filter myself after plumbing work?

No. The inlet filter and strainer sit behind the casing on the domestic water connection and belong to a service visit. The safe steps are running the taps, checking that the isolation valve was reopened, and having the boiler's domestic side diagnosed if hot water does not return.

Who arranges the repair when a rental has no hot water?

The property owner or manager. Report the problem in writing with the display code and whether the heating still works, and let them arrange a licensed contractor. Technical Safety BC states that landlords must have gas appliances inspected and serviced annually by a licensed contractor and keep the records.

In a strata, is the boiler my responsibility or the building's?

It depends on what the boiler serves. A building-wide hot-water loss is a common-property matter for the strata corporation or its manager, while an in-suite combi is usually the owner's or landlord's responsibility. The building manager or council can confirm which system serves your unit.

My combi's hot water goes cold when the heating comes on. Is that normal?

Some cooling while a tap is open is normal, because a combi gives domestic hot water priority and pauses or limits the heating circuit until the tap closes. Water that never reaches temperature is not normal and points at the diverter valve, the plate heat exchanger or the controls.

The water is lukewarm, not cold. Is that a different problem?

Yes, and the difference matters. Lukewarm water usually means the boiler is firing but transferring too little heat, which points at a scaled plate exchanger, a sensor reading incorrectly, a drifting mixing valve or a temperature setting. Completely cold water points instead at the call for heat and the flow sensor.

I lost hot water right after the boiler was serviced. What should I do?

Check that the cold-water isolation valve was fully reopened, run the affected hot tap fully open for a minute or two to clear air, and read the display. If it still will not fire, call whoever did the work: air, debris at the inlet filter or a setting changed during the visit are the usual causes, and a return visit under the same job is normal.

Could the hot-water temperature setting be the whole problem?

It can be. Many combis let the household set the domestic hot-water temperature, and a setting turned down or changed by accident produces lukewarm water with nothing wrong with the appliance. Confirm the setting if you know where it is, then have the actual temperature and flow measured before assuming a fault.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 15, 2026. Last updated September 15, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate