Skip to content
Boilers.caby ROMA Heating & Cooling

Bosch Thermotechnology · Error codes

Bosch/Buderus GB312 6L 561 — 5 Power-up Sequences (power Supply Disconnection during Burner Start-up).

6L 561

Needs attentionBuderus Logano plus GB312 commercial condensing boilers (SAFe fault displays, IOM 6 720 806 273)

5 power-up sequences (power supply disconnection during burner start-up). The burner control unit has switched off 5 times during the burner start-up sequence. Checks: Check the 120V power supply to the control unit. Remedy: Reset burner control unit. Rectify power supply problem. The table classifies it as V (interlocking).

Applies to

This fault code is displayed by the Logamatic BC10 basic control unit and MC10 control unit (SAFe fault codes) on Logano plus GB312 models (90–280), as documented in Buderus Logano plus GB312 Installation and Service Instructions, doc 6 720 806 273 (01.2013), section 10.2.2 Table 23 Fault displays (6 720 806 273). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: Logamatic BC10 basic control unit and MC10 control unit (SAFe fault codes). Source manual: 6 720 806 273 (2013-01).

Why a code is not a diagnosis

The code reports the condition the control detected; the underlying cause must be confirmed on site by a licensed technician using the manufacturer's procedure.

Safe things to observe

  • Note the exact code, when it appears and what the appliance was doing.
  • If the appliance has stopped, call a technician rather than repeatedly restarting it.
  • If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.

Do not

  • Do not ignore a code that returns after a reset.

How professional service helps

  1. A licensed technician diagnoses the cause with the manufacturer's test procedure.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for Bosch Thermotechnology Buderus GB312 (Logano plus GB312).

Frequently asked questions

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate