Buderus G234X/45/5

The Buderus G234X/45/5 is a discontinued atmospheric cast-iron gas boiler with a 187 MBTU/hr ignition heat load, 154 MBTU/hr nominal output and 84.1% AFUE.

DiscontinuedHistorically in Canada

Key figures

Max input
Max CSA output
AFUE
84.1 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Buderus G234X/45/5 in practice

Best suited to

    Applicability and support

    Model number
    G234X/45/5
    Canadian availability
    historical
    Production status
    discontinued
    ROMA supplies
    Confirmed at consultation
    ROMA services
    Confirmed at consultation
    Warranty
    Not verified

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Specifications

    Published specifications

    Values as published by Bosch Thermotechnology. Units are shown with every value; notes flag conflicting sources or missing figures.

    Buderus G234X/45/5 specifications
    SpecificationValueNote
    Input
    Ignition heat load187 MBTU/hr187,000 BTU/hr per the dimensions table.
    Output
    Nominal output154 MBTU/hr154,000 BTU/hr.
    Net IBR rating134 MBH
    Efficiency
    Efficiency (AFUE)84.1 %Buderus G124X/G234X/G334X brochure.
    Venting and air
    Vent size7"Atmospheric gas boiler with draft hood and damper (damper included per brochure).
    Physical and connections
    Number of burner rods3
    Dry weight487 lb
    Water volume6.1 US gal
    Operating limits and other
    Gas connection3/4"
    FuelNatural gas or propaneNG and propane orifice tables are printed in the manual.

    Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Questions about the Buderus G234X/45/5?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.