Skip to content
Boilers.caby ROMA Heating & Cooling

Bosch Thermotechnology · Series

Bosch Thermotechnology Buderus G615 (Logano G615)

The Buderus G615 (Logano G615) is a discontinued commercial cast-iron sectional boiler block for oil, gas or combination burners, sold in eight sizes (570 to 1200) with 1,951 to 3,982 MBH gross output. Its manuals are in Bosch's US commercial-discontinued archive.

discontinuedhistoricalNatural gasPropanecommercial

Series facts

Type
non-condensing
Efficiency
Unknown
Fuel
Oil/gas-fired boiler block: the installation manual covers oil, gas and combination burners; approved burners are listed by Bosch Thermotechnology Corp. Fuel-oil capability is printed in the manual but is not represented in Boilers.ca's two-fuel schema.
Venting
Non-condensing cast-iron sectional boiler; the technical table prints 284 °F flue gas at 60% partial load and 338-356 °F at full load, with chimney/vent design following the installation manual and local code.
Models documented
8
Warranty
Not verified

About the Buderus G615 (Logano G615)

The G615 is the largest Buderus cast-iron sectional block in the discontinued commercial archive, using Thermostream return-water mixing and built for forced-draft oil, gas or combination burners. Eight sizes are documented by boiler capacity - 570, 660, 740, 820, 920, 1020, 1110 and 1200 - with 9 to 16 sections, gross output from 1,951 to 3,982 MBH (570 to 1200 kW), net AHRI ratings of 1,697 to 3,463 MBH, gas input of 2,309 to 4,835 MBH, oil input of 9 to 16 GPH, net weights of 5,523 to 9,143 lb and water contents of 148.25 to 259.25 US gallons.

The G615 is discontinued: its installation/service and operating manuals plus the G315/G515/G615 brochure are published from the US 'Commercial Products - Discontinued' archive. It requires a field-supplied burner and external controls, so the manual set contains no on-board fault-code display. Note: the official technical table's unit labels for the flue-gas mass-flow rows are internally inconsistent (the rows are labelled °F but carry lb/s and kg/s values); Boilers.ca uses only the unambiguous output, input, weight and water rows.

Highlights

  • Eight sizes: 570, 660, 740, 820, 920, 1020, 1110, 1200 (9 to 16 sections)
  • Gross output 1,951 to 3,982 MBH; net AHRI 1,697 to 3,463 MBH
  • Gas input 2,309 to 4,835 MBH; oil input 9 to 16 GPH
  • Net weights 5,523 to 9,143 lb; water 148.25 to 259.25 US gal
  • Oil, gas or combination burner (field-supplied; approved list by Bosch)

Models

Buderus G615 (Logano G615) models

One canonical page per model with input, output and efficiency kept separate.

Bosch Thermotechnology

Buderus G615/570

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/570 is a discontinued commercial cast-iron boiler block with 9 sections, 1,951 MBH gross output and 1,697 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/660

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/660 is a discontinued commercial cast-iron boiler block with 10 sections, 2,242 MBH gross output and 1,950 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/740

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/740 is a discontinued commercial cast-iron boiler block with 11 sections, 2,532 MBH gross output and 2,202 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/820

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/820 is a discontinued commercial cast-iron boiler block with 12 sections, 2,822 MBH gross output and 2,454 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/920

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/920 is a discontinued commercial cast-iron boiler block with 13 sections, 3,112 MBH gross output and 2,706 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/1020

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/1020 is a discontinued commercial cast-iron boiler block with 14 sections, 3,402 MBH gross output and 2,958 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/1110

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/1110 is a discontinued commercial cast-iron boiler block with 15 sections, 3,692 MBH gross output and 3,210 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/1200

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/1200 is a discontinued commercial cast-iron boiler block with 16 sections, 3,982 MBH gross output and 3,463 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Buderus G615/570 and Buderus G615/660 and Buderus G615/740 and Buderus G615/820 and Buderus G615/920 and Buderus G615/1020 and Buderus G615/1110 and Buderus G615/1200
SpecificationBuderus G615/570Buderus G615/660Buderus G615/740Buderus G615/820Buderus G615/920Buderus G615/1020Buderus G615/1110Buderus G615/1200
input-min
input-max
output-max
afue
turndown
vent-max-3
vent-max-2
Weight, net5,523 lb6,056 lb6,592 lb7,125 lb7,661 lb8,179 lb8,715 lb9,143 lb

Read the full comparison: Buderus G615/570 vs G615/1200

Read the full comparison: Buderus G615/570 vs Buderus G615/660

Read the full comparison: Buderus G615/660 vs Buderus G615/740

Read the full comparison: Buderus G615/740 vs Buderus G615/820

Error codes and alerts

Buderus G615 (Logano G615) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Services for Bosch Thermotechnology boilers

Frequently asked questions

What is the G615's largest size?

The G615/1200: 16 boiler sections, 3,982 MBH gross output (1,200 kW), 4,835 MBH gas input, 9,143 lb net weight and 259.25 US gallons of boiler water, per the installation manual technical table.

Does the G615 include a burner and controls?

No. It is a boiler block for forced-draft firing; a field-supplied burner is required, approved burners are listed by Bosch, and controls are external (aquastat, Logamatic 4000 or BMS).

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate