Burnham SteamMax STMX175

The Burnham SteamMax STMX175 is a current gas-fired cast-iron steam boiler: 175 MBH input for 144 MBH output and a 108 MBH net AHRI steam rating (450 sq ft) at 82% AFUE, with 5 sections, a 7" vent and a 3/4" NPT gas connection.

CurrentCanadian status unknown

Key figures

Max input
Max CSA output
AFUE
82 %
Min input
Natural gasHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham SteamMax STMX175 in practice

The SteamMax STMX175 is one of the twelve sizes in U.S. Boiler Company's current SteamMax gas-fired steam line. Its PDS ratings row prints 175 MBH input, 144 MBH output and a 108 MBH net AHRI steam rating covering 450 sq ft (1.333 piping and pickup allowance), at 82% AFUE.

The boiler uses a cast-iron sectional design with metal push nipples, wide internal waterways, heat transfer pins below the water line, no heat transfer pins above the water line and a large steam chest, with optimized stainless steel burners, a step-opening gas valve, a probe-type low-water cut-off, an industrial-grade pressuretrol, a rear low-profile draft diverter, a vent damper (models 075–299) and 2 in. risers. Supply and return are 2 in. NPT with a 2 in. skimming port tapping, the gas connection is 3/4" NPT, and the unit ships with a 15 PSI relief valve and gauge glass; near-boiler piping kits are documented for the residential sizes.

The 100–550 MBH sizes are documented as residential builds with combustion controls and continuous-retry ignition (Honeywell S8610M). U.S. Boiler prints a 10-year limited heat exchanger warranty and a 10-year limited waterside corrosion warranty. No official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and steam work belongs with a licensed contractor.

Best suited to

  • Steam systems needing about 450 sq ft of connected radiation
  • Residential steam replacements in the 75–299 MBH class
  • Installations comparing SteamMax with the still-sold Independence line

Applicability and support

Model number
STMX175
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham SteamMax STMX175 specifications
SpecificationValueNote
Input
Input175 MBHInput per the official SteamMax Product Data Sheet ratings table (natural gas only; rated up to 2,000 ft).
Output
Output144 MBHOutput per the official SteamMax ratings table.
Net AHRI steam rating108 MBHNet steam rating 108 MBH covering 450 sq ft, based on a piping and pickup allowance of 1.333 per the PDS.
Efficiency
Efficiency (AFUE)82 %AFUE per the official SteamMax ratings table (82.0% on the 075–299 sizes).
Venting and air
Vent size7"Vent size per the SteamMax ratings table; rear-mounted low-profile draft diverter with a vent damper on models 075–299.
Physical and connections
Sections5Cast-iron section count per the SteamMax ratings table.
Gas connection3/4" NPTGas connection per the SteamMax dimensions table; supply and return are 2 in. NPT with a 2 in. skimming port tapping.
Approximate shipping weight729 lbApproximate shipping weight per the SteamMax ratings table; weights marked for knock-down units where noted.
Operating limits and other
Warranty10-year limited heat exchanger warranty and 10-year limited waterside corrosion warrantyPer the official SteamMax product page and PDS standard equipment (residential only, under 300 MBH for the waterside coverage wording on the page).
ConstructionCast-iron sectional design with metal push nipples, wide waterways, heat transfer pins below the water line and a large steam chestPer the official PDS standard equipment; optimized stainless steel burners, step-opening gas valve, probe-type low-water cut-off and industrial-grade pressuretrol.
FuelNatural gas onlyThe SteamMax PDS ratings table is headed '(Natural Gas Only)'.

Frequently asked questions

What are the SteamMax STMX175's ratings?

175 MBH input, 144 MBH output and a 108 MBH net AHRI steam rating (450 sq ft) at 82% AFUE per the official PDS.

Is the SteamMax STMX175 a residential or commercial build?

A residential build (100–550 MBH) with continuous-retry ignition per the PDS standard equipment.

What fuel does the SteamMax STMX175 use?

Natural gas only — the PDS ratings table is headed '(Natural Gas Only)'.

Questions about the Burnham SteamMax STMX175?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate