Skip to content
Boilers.caby ROMA Heating & Cooling

Burnham · SteamMax & Independence (gas steam)

Burnham Independence IN4I

The Burnham Independence IN4I is a current gas-fired cast-iron steam boiler: 105 MBH maximum input for 87 MBH heating capacity and a 65 MBH net AHRI steam rating (271 sq ft) at 82% AFUE, requiring a 5 in. x 15 ft chimney and shipping at about 420 lb.

CurrentCanadian status unknown

Key figures

Max input
105 MBH
Max CSA output
AFUE
82 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Independence IN4I in practice

The Independence IN4I is one of the 10 sizes U.S. Boiler Company documents for the Independence gas-fired cast-iron steam line. Its official submittal row prints 105 MBH maximum input, 87 MBH heating capacity and a 65 MBH net AHRI steam rating covering 271 sq ft (1.333 piping and pickup allowance), at 82% AFUE, with a 5 in. x 15 ft minimum chimney and a 420 lb approximate shipping weight.

The line is built with cast-iron push nipples, Honeywell operating controls, a vent damper and a rugged steel base under an insulated powder-coated steel jacket; the Independence PV variants are specifically configured as direct-vent products for homes with a damaged or irreparable chimney. The maximum working pressure is 15 PSI steam, and the product page prints a limited 10-year heat exchanger warranty plus a one-year manufacturer's parts warranty.

LP gas is available on the IN3–IN9 sizes per the submittal footnote and product page. No official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and steam work belongs with a licensed contractor.

Best suited to

  • Steam systems needing about 271 sq ft of connected radiation
  • Residential steam replacements on a chimney-vented system
  • Installations comparing chimney-vented and Independence PV direct-vent configurations

Applicability and support

Model number
IN4I
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Independence IN4I specifications
SpecificationValueNote
Input
Maximum input105 MBHMaximum input per the official Independence submittal/PDS ratings table (sea level to 2,000 ft; reduce 4% per 1,000 ft above sea level in the U.S.).
Output
Heating capacity87 MBHHeating capacity per the official Independence submittal ratings table.
Net AHRI steam rating65 MBHNet steam rating 65 MBH covering 271 sq ft, based on a piping and pickup allowance of 1.333 per the submittal.
Efficiency
Efficiency (AFUE)82 %AFUE per the official Independence submittal ratings table (up to 82%).
Venting and air
Minimum chimney requirement5 in. x 15 ftRound chimney diameter x height measured from the top of the draft hood to the top of the chimney, per the submittal (15 ft minimum).
Physical and connections
Approximate shipping weight420 lbApproximate shipping weight per the official submittal.
Maximum working pressure15 PSI steamAs printed on the official Independence submittal.
Operating limits and other
FuelNatural gas or LP gas (on select chimney-vented models)Per the submittal footnote and product page: LP is available on the IN3–IN9 sizes.
ConstructionCast-iron sections with push nipples, Honeywell operating controls, vent damper and insulated steel jacketPer the official Independence product page; the PV variants are configured as direct-vent products for homes with a damaged or irreparable chimney.
WarrantyLimited 10-year heat exchanger warranty plus a one-year manufacturer's parts warrantyAs printed on the official Independence product page.

Frequently asked questions

What are the Independence IN4I's ratings?

105 MBH maximum input, 87 MBH heating capacity and a 65 MBH net AHRI steam rating (271 sq ft) at 82% AFUE per the official submittal.

What chimney does the IN4I need?

A 5 in. x 15 ft round chimney, measured from the top of the draft hood to the top of the chimney (15 ft minimum) per the official submittal.

Can the IN4I run on propane?

Yes — LP gas is available on the IN3–IN9 sizes per the submittal footnote and product page.

Questions about the Burnham Independence IN4I?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate