Crown Aruba 6 AWR038C

The Crown Aruba 6 AWR038C is the smallest Aruba 6 (two sections; not for installation above 2,000 ft): a fixed 38 MBH input for 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE, with a 4" flue collar, 1 US gallons of water content and 202 lb approximate shipping weight.

CurrentCanadian status unknown

Key figures

Max input
38 MBH
Max CSA output
AFUE
84 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Aruba 6 AWR038C in practice

The Aruba 6 AWR038C is a cast-iron, gas-fired natural-draft hot water boiler rated at a fixed 38 MBH input with 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating (1.15 piping and pickup allowance) at 84.0% AFUE per the AWR space-heating ratings table (literature PN 980784; I&O manual 112933-01).

The product dimensions table lists a 4" flue collar, 1 US gallon(s) of water content, a 13" "W" dimension, 202 lb approximate shipping weight and 143 lb boiler weight. The boiler carries the integrated boiler control with integral LWCO, vents as Category I into an approved chimney, and is piped standard on the left side with field conversion to right-side piping available.

The two-section AWR038C is not to be installed above 2,000 ft (literature sheet). Boilers.ca documents this model at model level from the product page, literature and I&O manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas and venting work belongs with a licensed contractor.

Best suited to

  • Homes with a chimney-vented design load near the 38 MBH fixed input
  • Owners comparing the current Aruba 6 ratings with a legacy Aruba 4/5 installation
  • Replacement projects wanting an integrated boiler control with integral LWCO

Applicability and support

Model number
AWR038C
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Aruba 6 AWR038C specifications
SpecificationValueNote
Input
Input38 MBHFixed input (no modulation) per the AWR space-heating ratings table (product page; literature PN 980784). Input ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity32 MBHDOE heating capacity per the AWR space-heating ratings table.
Net AHRI water rating28 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15 per the ratings table.
Efficiency
Efficiency (AFUE)84 %84.0% AFUE printed for every Aruba 6 size per the AWR space-heating ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Flue collar diameter4 inFlue collar diameter per the product dimensions table (literature PN 980784).
VentingCategory I natural draft into an approved chimneyCast-iron boiler with a built-in rear draft diverter and a vent damper monitored by the integrated boiler control (I&O manual 112933-01).
Physical and connections
Water content1 galBoiler water content per the product dimensions table.
"W" dimension13""W" dimension per the product dimensions table.
Approx. shipping weight202 lbApproximate shipping weight per the product dimensions table.
Boiler weight143 lbBoiler (bare) weight per the product dimensions table.
Supply/return connections1-1/4" NPTSupply and return connections 1-1/4" NPT; standard piping on the left side, field convertible to right side (I&O manual; product page).
Operating limits and other
FuelNatural gas or propaneNG or LP with fuel conversion kits published per model on the literature sheet; AWR038C not to be installed above 2,000 ft and other sizes standard-build approved to 5,400 ft with altitude kits above.
ControlIntegrated boiler control with integral LWCOTemperature control, relay and ignition functions in a single module located inside the jacket (product page); additional circulator output for a second zone or indirect water heater.

Frequently asked questions

What are the AWR038C's ratings?

38 MBH fixed input, 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE per the AWR space-heating ratings table.

Is the AWR038C a condensing boiler?

No — the Aruba 6 is a cast-iron, Category I natural-draft boiler with a built-in rear draft diverter, vented into an approved chimney.

Can the Aruba 6 run on propane?

Yes — it is available in NG or LP with published fuel conversion kits; input ratings for elevations above 2,000 ft are covered in the I&O manual's Appendix D.

Questions about the Crown Aruba 6 AWR038C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.