Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Series

Crown Boiler Co. Aruba 6

The Aruba 6 (AWR) is Crown's current cast-iron, gas-fired natural-draft hot water boiler: eight fixed-input sizes AWR038C through AWR280C (38–280 MBH) at 84.0% AFUE with an integrated boiler control and integral low water cut-off, succeeding the legacy Aruba 5/Aruba 4 AWR lines.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84% AFUE
Fuel
Natural or LP gas: fuel conversion kits are published by model (AWR038C has its own kit numbers; AWR070C–AWR280C share NG-to-LP and LP-to-NG kits). AWR038C must not be installed above 2,000 ft; other sizes are standard-build approved to 5,400 ft with conversion kits above.
Venting
Category I natural draft into an approved chimney (cast-iron boiler with a built-in rear draft diverter and a vent damper monitored by the integrated boiler control); standard piping is on the left side, field convertible to right side piping.
Models documented
8
Warranty
Not verified

84.0% AFUE printed for every AWR038C–AWR280C size in the space-heating ratings table (product page; literature PN 980784; I&O manual 112933-01).

About the Aruba 6

The Aruba 6 is the current Crown (Velocity Boiler Works) cast-iron gas hot water line, listed on the 2026 residential gas menu as 'Aruba 6 (AWR)'. The product page introduces it as building on the Aruba 5 with the same flexibility: eight sizes from 38 to 280 MBH input at 84% AFUE, an integrated boiler control located inside the jacket with temperature control, relay and ignition functions in a single module plus an integral LWCO, a built-in rear draft diverter, an additional circulator output for a second zone or an indirect water heater, and natural or LP gas with published fuel conversion kits.

Two installation changes are called out on the page: standard piping is now on the left side (the boiler is field convertible to right-side piping), and the standard build is approved for 5,400 ft altitude with conversion kits for installations above that — while the two-section AWR038C is not to be installed above 2,000 ft. The AWR space-heating ratings table prints 38/70/105/140/175/210/245/280 MBH inputs with DOE heating capacities of 32–234 MBH and net AHRI water ratings of 28–203 MBH (1.15 piping and pickup allowance) at 84.0% AFUE across the board; the product dimensions table adds flue collar diameter (4"–8"), water content (1–8 gallons), the 'W' dimension (13"–31"), approximate shipping weight (202–564 lb) and boiler weight (143–484 lb).

Aruba 6 is the successor Boilers.ca documents against the legacy Aruba 4 (AWR038E–AWR280E, discontinued) — and the intermediate Aruba 5 which the Aruba 5.1 IOM (9807815-Rev-E, 1/24) still covers on the legacy site. Boilers.ca documents all eight AWR038C–AWR280C models at model level. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas and venting work belongs with a licensed contractor.

Highlights

  • Current Crown cast-iron gas water line: AWR038C–AWR280C, eight fixed-input sizes 38–280 MBH
  • 84.0% AFUE printed for every size; DOE heating capacities 32–234 MBH
  • Integrated boiler control with integral LWCO; built-in rear draft diverter
  • Category I natural draft into an approved chimney; standard piping left side, field convertible right
  • Standard build approved to 5,400 ft altitude (conversion kits above); AWR038C limited to 2,000 ft
  • Supersedes the legacy Aruba 5 and Aruba 4 (AWR038E–AWR280E) lines
  • Model-level pages published on Boilers.ca; I&O manual 112933-01 (7/25) linked here

Models

Aruba 6 models

One canonical page per model with input, output and efficiency kept separate.

Crown Boiler Co.

Crown Aruba 6 AWR038C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR038C is the smallest Aruba 6 (two sections; not for installation above 2,000 ft): a fixed 38 MBH input for 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE, with a 4" flue collar, 1 US gallons of water content and 202 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR070C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR070C is a 70 MBH three-section size: a fixed 70 MBH input for 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating at 84.0% AFUE, with a 4" flue collar, 2 US gallons of water content and 254 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR105C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR105C is a 105 MBH four-section size: a fixed 105 MBH input for 88 MBH DOE heating capacity and a 77 MBH net AHRI water rating at 84.0% AFUE, with a 5" flue collar, 3 US gallons of water content and 304 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR140C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR140C is a 140 MBH five-section size: a fixed 140 MBH input for 117 MBH DOE heating capacity and a 102 MBH net AHRI water rating at 84.0% AFUE, with a 6" flue collar, 4 US gallons of water content and 357 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR175C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR175C is a 175 MBH six-section size: a fixed 175 MBH input for 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating at 84.0% AFUE, with a 6" flue collar, 5 US gallons of water content and 405 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR210C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR210C is a 210 MBH seven-section size: a fixed 210 MBH input for 176 MBH DOE heating capacity and a 153 MBH net AHRI water rating at 84.0% AFUE, with a 7" flue collar, 6 US gallons of water content and 462 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR245C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR245C is a 245 MBH eight-section size: a fixed 245 MBH input for 205 MBH DOE heating capacity and a 178 MBH net AHRI water rating at 84.0% AFUE, with a 7" flue collar, 7 US gallons of water content and 518 lb approximate shipping weight.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 6 AWR280C

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Aruba 6 AWR280C is the largest Aruba 6 (nine sections): a fixed 280 MBH input for 234 MBH DOE heating capacity and a 203 MBH net AHRI water rating at 84.0% AFUE, with a 8" flue collar, 8 US gallons of water content and 564 lb approximate shipping weight.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Crown Aruba 6 AWR038C and Crown Aruba 6 AWR070C and Crown Aruba 6 AWR105C and Crown Aruba 6 AWR140C and Crown Aruba 6 AWR175C and Crown Aruba 6 AWR210C and Crown Aruba 6 AWR245C and Crown Aruba 6 AWR280C
SpecificationCrown Aruba 6 AWR038CCrown Aruba 6 AWR070CCrown Aruba 6 AWR105CCrown Aruba 6 AWR140CCrown Aruba 6 AWR175CCrown Aruba 6 AWR210CCrown Aruba 6 AWR245CCrown Aruba 6 AWR280C
input-min
Input38 MBH70 MBH105 MBH140 MBH175 MBH210 MBH245 MBH280 MBH
output-max
Efficiency (AFUE)84 %84 %84 %84 %84 %84 %84 %84 %
turndown
vent-max-3
vent-max-2
Approx. shipping weight202 lb254 lb304 lb357 lb405 lb462 lb518 lb564 lb

Read the full comparison: Crown Aruba 6 AWR038C vs AWR070C

Read the full comparison: Crown Aruba 6 AWR070C vs AWR105C

Read the full comparison: Crown Aruba 6 AWR105C vs AWR140C

Read the full comparison: Crown Aruba 6 AWR140C vs AWR175C

Error codes and alerts

Aruba 6 alerts

  • 4Aruba control (Err codes)
  • 6Aruba control (Err codes)
  • 18Aruba control (Err codes)
  • 23Aruba control (Err codes)
  • 32Aruba control (Err codes)
  • 55Aruba control (Err codes)
  • 56Aruba control (Err codes)
  • 57Aruba control (Err codes)
  • 58Aruba control (Err codes)
  • 59Aruba control (Err codes)
  • 60Aruba control (Err codes)
  • 61Aruba control (Err codes)
  • 63Aruba control (Err codes)
  • 64Aruba control (Err codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Aruba 6 available in Canada?

No official Canadian-sales statement was found on the official pages checked on September 9, 2026, so canadianStatus is recorded as 'unknown'. Confirm supply through a licensed distributor.

What replaced the Aruba 4?

The current catalogue lists Aruba 6 (AWR038C–AWR280C) as the Aruba line; the Aruba 4 (AWR038E–AWR280E) is legacy and discontinued, and the Aruba 5 sat between them (Aruba 6 page copy: 'building on the trusted performance of the Aruba 5').

Does the Aruba 6 need a chimney?

Yes — it is a Category I natural-draft boiler with a built-in rear draft diverter and a vent damper monitored by the control, vented into an approved chimney. Homes without a chimney should look at sealed-combustion/direct-vent designs.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate