Crown Boiler Co. · Bali 3

Crown Bali 3 BWF063CL

The Crown Bali 3 BWF063CL is the propane 3-section size of the induced-draft cast-iron water line: a fixed 63 MBH input for 54 MBH heating capacity and a 47 MBH net AHRI rating at 85% AFUE.

CurrentCanadian status unknown

Key figures

Max input
63 MBH
Max CSA output
AFUE
85 %
Min input
PropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Bali 3 BWF063CL in practice

The Bali 3 BWF063CL is a cast-iron, induced-draft gas hot water boiler printed in the BWF space-heating ratings table as a PROPANE model: fixed 63 MBH input with 54 MBH heating capacity and a 47 MBH net AHRI water rating (1.15 piping and pickup allowance) at 85% AFUE. It builds on 3 cast-iron sections and carries the integrated boiler control with integral LWCO.

The literature sheet lists a 3" vent connection, 2 US gallons of water content and approximately 260 lb shipping weight for this size, with optional direct vent kit PN 110019-03; the I&O manual specification table adds overall dimensions of 26-1/2" deep by 12-3/4" wide by 37-3/4" high with a 1/2" NPT gas connection, 1-1/4" NPT supply/return connections and 50 psig working pressure. Standard piping is left side only (rolling change per the product page).

Boilers.ca documents this model at model level from the product page, literature (PN 980632) and I&O manual (PN 113323-02). No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas and venting work belongs with a licensed contractor.

Best suited to

  • Homes with a chimney-vented design load near 63 MBH on propane
  • Replacement projects matching a cast-iron induced-draft boiler in the Bali family
  • Installations wanting the optional direct-vent capability (kit PN 110019-03)

Applicability and support

Model number
BWF063CL
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Bali 3 BWF063CL specifications
SpecificationValueNote
Input
Input63 MBHFixed input per the BWF space-heating ratings table (product page; literature PN 980632); PROPANE model. Input ratings apply to elevations up to 2,000 ft.
Output
DOE heating capacity54 MBHHeating capacity per the BWF space-heating ratings table.
Net AHRI water rating47 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15 per the ratings table.
Efficiency
Efficiency (AFUE)85 %AFUE per the BWF space-heating ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingInduced draft; 3" vent connectionInduced-draft boiler with a 3" vent per the ratings table; optional direct vent kit PN 110019-03 allows direct connection of outside combustion air (product page).
Physical and connections
Cast-iron sections3Number of sections per the ratings table.
Dimensions (D × W × H)26-1/2" × 12-3/4" × 37-3/4"Depth, width and height per the Bali BWF I&O manual specification table (PN 113323-02).
Gas connection1/2" NPTGas connection size per the ratings/dimension table (1/2" NPT).
Boiler water content2 galWater content per the literature sheet.
Approx. shipping weight260 lbApproximate shipping weight per the literature sheet.
Operating limits and other
Maximum allowable working pressure50 psigWorking pressure per the I&O manual specification table.
FuelPropane (LP)PROPANE model as printed in the BWF space-heating ratings table; specific sea-level and high-altitude models exist per the product page.
ControlIntegrated boiler control with integral LWCOIntegrated boiler control with integral low water cut-off per the product page.

Frequently asked questions

What are the BWF063CL's ratings?

63 MBH fixed input, 54 MBH heating capacity and a 47 MBH net AHRI water rating at 85% AFUE per the BWF space-heating ratings table.

Is the BWF063CL a condensing boiler?

No — the Bali 3 is a cast-iron, induced-draft boiler rated up to 85% AFUE (84.0% on the largest sizes); it is not a condensing design.

What venting does the BWF063CL need?

An induced-draft 3" vent connection to a chimney, or a direct-vent installation using the optional direct vent kit PN 110019-03 (product page).

Questions about the Crown Bali 3 BWF063CL?