Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Series

Crown Boiler Co. Bali 3

The Bali 3 (BWF) is Crown's current cast-iron, induced-draft gas hot water boiler: six natural-gas and six propane models (12 total) from 63 to 245 MBH input at up to 85% AFUE, with an integrated boiler control with integral LWCO and an optional direct-vent kit.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
85% AFUE
Fuel
Six natural-gas models (BWF…CN, 70–245 MBH input) and six propane models (BWF…CL, 63–220.5 MBH input) are printed as separate models in the ratings tables — 12 models total.
Venting
Induced-draft, fan-assisted boiler for chimney venting; an optional direct vent kit (PN 110019-03 through -08) allows direct connection of outside combustion air so the boiler can also be direct vented (product page). Vent size 3" on most models and 4" on the 245 MBH NG / 220.5 MBH LP sizes.
Models documented
12
Warranty
Not verified

85.0% AFUE printed on eleven of the twelve models; the largest NG (BWF245CN) and LP (BWF220CL) sizes print 84.0% AFUE.

About the Bali 3

The Bali 3 is the current Crown (Velocity Boiler Works) induced-draft cast-iron gas boiler, listed on the 2026 residential gas menu as 'Bali 3 (BWFC)'. The product page describes a gas-fired hot water boiler that 'has many of the same features of the previous Bali 2 (BWF)', offered in six sizes in natural or LP gas (NG 70–245 MBH input, LP 63–220 MBH input), up to 85% AFUE, with specific sea-level and high-altitude models, an integrated boiler control with integral LWCO, and an optional direct vent kit that allows direct connection of outside combustion air.

One change is flagged on the page: standard piping is now left side only and cannot be field converted to right-side piping (a rolling change noted by the manufacturer). The BWF space-heating ratings table prints twelve models — BWF070CN, BWF105CN, BWF140CN, BWF175CN, BWF210CN, BWF245CN and BWF063CL, BWF094CL, BWF126CL, BWF157CL, BWF189CL, BWF220CL — with inputs of 63 to 245 MBH, heating capacities of 54–208 MBH and net AHRI water ratings of 47–181 MBH (1.15 allowance) at 85.0% AFUE (84.0% on the two largest).

The literature sheet (PN 980632, 2/26) adds per-model sections (3–8), width (12-3/4"–27-3/4"), gas connection (1/2" NPT, 3/4" NPT on the 210/220/245-class sizes), vent size (3", 4" on the largest), water content (2–7 gallons), approximate shipping weight (260–525 lb) and the optional direct-vent kit PN (110019-03 through -08). Boilers.ca documents all twelve models at model level. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas and venting work belongs with a licensed contractor.

Highlights

  • Current Crown induced-draft cast-iron gas water line — 12 models (6 NG + 6 LP)
  • NG 70–245 MBH and LP 63–220.5 MBH input; up to 85% AFUE (84.0% on the two largest)
  • Integrated boiler control with integral LWCO; specific sea-level and high-altitude models
  • Optional direct vent kit (PN 110019-03…-08) allows direct-vent installation
  • Standard piping left side only — not field convertible to right side (product page)
  • Model-level pages published on Boilers.ca; I&O manual 113323-02 (12/25) linked here

Models

Bali 3 models

One canonical page per model with input, output and efficiency kept separate.

Crown Boiler Co.

Crown Bali 3 BWF070CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF070CN is the natural-gas 3-section size of the induced-draft cast-iron water line: a fixed 70 MBH input for 60 MBH heating capacity and a 52 MBH net AHRI rating at 85% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF105CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF105CN is the natural-gas 4-section size of the induced-draft cast-iron water line: a fixed 105 MBH input for 90 MBH heating capacity and a 78 MBH net AHRI rating at 85% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF140CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF140CN is the natural-gas 5-section size of the induced-draft cast-iron water line: a fixed 140 MBH input for 120 MBH heating capacity and a 104 MBH net AHRI rating at 85% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF175CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF175CN is the natural-gas 6-section size of the induced-draft cast-iron water line: a fixed 175 MBH input for 150 MBH heating capacity and a 130 MBH net AHRI rating at 85% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF210CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF210CN is the natural-gas 7-section size of the induced-draft cast-iron water line: a fixed 210 MBH input for 179 MBH heating capacity and a 156 MBH net AHRI rating at 85% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF245CN

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Bali 3 BWF245CN is the natural-gas 8-section size of the induced-draft cast-iron water line: a fixed 245 MBH input for 208 MBH heating capacity and a 181 MBH net AHRI rating at 84% AFUE.

Natural gasHeating-only

Crown Boiler Co.

Crown Bali 3 BWF063CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF063CL is the propane 3-section size of the induced-draft cast-iron water line: a fixed 63 MBH input for 54 MBH heating capacity and a 47 MBH net AHRI rating at 85% AFUE.

PropaneHeating-only

Crown Boiler Co.

Crown Bali 3 BWF094CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF094CL is the propane 4-section size of the induced-draft cast-iron water line: a fixed 94.5 MBH input for 81 MBH heating capacity and a 70 MBH net AHRI rating at 85% AFUE.

PropaneHeating-only

Crown Boiler Co.

Crown Bali 3 BWF126CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF126CL is the propane 5-section size of the induced-draft cast-iron water line: a fixed 126 MBH input for 108 MBH heating capacity and a 94 MBH net AHRI rating at 85% AFUE.

PropaneHeating-only

Crown Boiler Co.

Crown Bali 3 BWF157CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF157CL is the propane 6-section size of the induced-draft cast-iron water line: a fixed 157.5 MBH input for 135 MBH heating capacity and a 117 MBH net AHRI rating at 85% AFUE.

PropaneHeating-only

Crown Boiler Co.

Crown Bali 3 BWF189CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The Crown Bali 3 BWF189CL is the propane 7-section size of the induced-draft cast-iron water line: a fixed 189 MBH input for 161 MBH heating capacity and a 140 MBH net AHRI rating at 85% AFUE.

PropaneHeating-only

Crown Boiler Co.

Crown Bali 3 BWF220CL

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Crown Bali 3 BWF220CL is the propane 8-section size of the induced-draft cast-iron water line: a fixed 220.5 MBH input for 187 MBH heating capacity and a 163 MBH net AHRI rating at 84% AFUE.

PropaneHeating-only

Compare models in this series

Comparison of Crown Bali 3 BWF070CN and Crown Bali 3 BWF105CN and Crown Bali 3 BWF140CN and Crown Bali 3 BWF175CN and Crown Bali 3 BWF210CN and Crown Bali 3 BWF245CN and Crown Bali 3 BWF063CL and Crown Bali 3 BWF094CL and Crown Bali 3 BWF126CL and Crown Bali 3 BWF157CL and Crown Bali 3 BWF189CL and Crown Bali 3 BWF220CL
SpecificationCrown Bali 3 BWF070CNCrown Bali 3 BWF105CNCrown Bali 3 BWF140CNCrown Bali 3 BWF175CNCrown Bali 3 BWF210CNCrown Bali 3 BWF245CNCrown Bali 3 BWF063CLCrown Bali 3 BWF094CLCrown Bali 3 BWF126CLCrown Bali 3 BWF157CLCrown Bali 3 BWF189CLCrown Bali 3 BWF220CL
input-min
Input70 MBH105 MBH140 MBH175 MBH210 MBH245 MBH63 MBH94.5 MBH126 MBH157.5 MBH189 MBH220.5 MBH
output-max
Efficiency (AFUE)85 %85 %85 %85 %85 %84 %85 %85 %85 %85 %85 %84 %
turndown
vent-max-3
vent-max-2
Approx. shipping weight260 lb310 lb360 lb415 lb470 lb525 lb260 lb310 lb360 lb415 lb470 lb525 lb

Read the full comparison: Crown Bali 3 BWF063CL vs BWF070CN

Read the full comparison: Crown Bali 3 BWF070CN vs BWF094CL

Read the full comparison: Crown Bali 3 BWF094CL vs BWF105CN

Read the full comparison: Crown Bali 3 BWF105CN vs BWF126CL

Error codes and alerts

Bali 3 alerts

  • 2Bali control
  • 4Bali control
  • 6Bali control
  • 18Bali control
  • 23Bali control
  • 29Bali control
  • 32Bali control
  • 35Bali control
  • 57Bali control
  • 58Bali control
  • 59Bali control
  • 60Bali control
  • 61Bali control
  • 63Bali control
  • 64Bali control
  • 89Bali control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Bali 3 available in Canada?

No official Canadian-sales statement was found on the official pages checked on September 9, 2026, so canadianStatus is recorded as 'unknown'. Confirm supply through a licensed distributor.

Is the Bali 3 a condensing boiler?

No — it is a cast-iron, induced-draft (fan-assisted) boiler rated up to 85% AFUE that vents through a chimney, or direct-vent with the optional direct vent kit; it is not a condensing design.

Why are there twelve Bali 3 models?

Each of the six physical sizes is printed twice in the ratings table — once for natural gas (BWF…CN models, 70–245 MBH) and once for propane (BWF…CL models, 63–220.5 MBH).

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate