Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Phantom-X

Crown Phantom-X PHNTM285

The Crown Phantom-X PHNTM285 is the largest Phantom-X: 57 to 285 MBH input at 95.0% AFUE with 262 MBH gross output and a 228 MBH net AHRI rating on the Sage2.x control, connecting on 1-1/4" NPT supply/return at about 256 lb.

CurrentCanadian status unknown

Key figures

Max input
285 MBH
Max CSA output
AFUE
95 %
Min input
57 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Phantom-X PHNTM285 in practice

The PHNTM285 is the top Phantom-X size: 57–285 MBH input for 262 MBH heating capacity (gross output) and a 228 MBH net AHRI water rating at 95.0% AFUE (product ratings table; I&O manual 105357-06, 12/24). The stainless steel water-tube condensing platform runs the modulating burner at 5:1 turndown on the Sage2.x control with outdoor reset sensor, domestic priority, freeze protection and lead/lag for up to 8 boilers.

The unit stands 43-7/16" (B) tall with dimension A of 21-13/16", holds 2.4 gal of water, ships at about 256 lb, and steps its connections to 1-1/4" NPT supply/return with 3/4" NPT gas. Like the 210 it offers multiple direct-vent options (two-pipe and concentric per the manual) and stackable installation. Ratings reduce 4% per 1,000 ft above 2,000 ft, LP above 7,000 ft is not permitted, and Canadian installations above 4,500 ft should consult the authority having jurisdiction.

Best suited to

  • High-load homes and small commercial plants approaching 285 MBH input
  • Cascaded Sage2.x plants (lead/lag to 8 boilers) needing the largest Phantom-X size
  • Projects comfortable with 1-1/4" NPT near-boiler piping

Applicability and support

Model number
PHNTM285
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Phantom-X PHNTM285 specifications
SpecificationValueNote
Input
Input, minimum57 MBHMinimum input per the product ratings table (42 MBH on the PHNTM210, 57 MBH on the PHNTM285).
Input, maximum285 MBHMaximum input per the product ratings table; ratings apply to elevations up to 2,000 ft, reduced 4% per 1,000 ft above.
Output
Heating capacity (gross output)262 MBHHeating capacity marked as gross output per the product ratings table.
Net AHRI water rating228 MBHNet water rating based on a piping and pickup allowance of 1.15 per the product ratings table.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the product ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Physical and connections
Water content2.4 galWater content per the product ratings table.
Shipping weight256 lbApproximate shipping weight per the product ratings table.
Dimensions (A × B)21-13/16" × 43-7/16"Dimension A 21-13/16" and dimension B 43-7/16" per the product dimensions table.
Supply and return connections1-1/4" NPTSupply and return connection size per the product dimensions table.
Gas connection3/4" NPTGas connection size per the product dimensions table.
Operating limits and other
Turndown ratio5:1Modulating burner with 5:1 turndown ratio per the product page.
ControlSage2.x control with outdoor reset sensorDomestic water priority with priority protection, warm-weather shutdown, freeze protection, pump exercise, and multiple-boiler lead/lag for up to 8 boilers (product page).
FuelNatural gas or LPGShips as a natural gas boiler, field convertible to LP; no LP installations above 7,000 ft.

Frequently asked questions

What are the PHNTM285's ratings?

57–285 MBH input, 262 MBH gross heating capacity, a 228 MBH net AHRI water rating and 95.0% AFUE per the product ratings table.

How does the PHNTM285 differ from the PHNTM210?

Input rises from 210 to 285 MBH maximum (minimum 42 to 57 MBH), gross output from 194 to 262 MBH, net AHRI from 169 to 228 MBH, water content from 1.7 to 2.4 gal, and connections from 1"/1/2" NPT to 1-1/4"/3/4" NPT — the 285 also stands taller (43-7/16" vs 32-3/16").

Can the PHNTM285 be wall-hung?

Boilers.ca does not claim wall-mounting for the Phantom-X — the product page describes a stackable design for floor-space savings in small mechanical rooms. Buyers comparing a smaller footprint should look at the Phantom II heat-only line.

Questions about the Crown Phantom-X PHNTM285?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate