Skip to content
Boilers.caby ROMA Heating & Cooling

Dunkirk Boilers · DMG (DMG-240 / DMG-380)

Dunkirk DMG-380

The Dunkirk DMG-380 is the floor-standing condensing boiler of the DMG pair — a 'Commercial Offering' per the official page: 35 to 379 MBH input, 348 MBH heating capacity, 95% thermal efficiency, 10.5:1 turndown and an 80 psi ASME rating.

CurrentCanadian status unknown

Key figures

Max input
379 MBH
Max CSA output
AFUE
Min input
35 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Dunkirk DMG-380 in practice

The DMG-380 is the floor-standing member of Dunkirk's DMG condensing pair, which the official page labels a 'Commercial Offering'. The brochure table prints 379 MBH maximum input (35 minimum) with 348 MBH heating capacity, a 303 MBH net water rating and 95% thermal efficiency, with a 10.5:1 modulation turndown ratio per the product page.

It is built around a 316L stainless steel heat exchanger and burner with direct spark ignition and a combination flame sensor and igniter, a built-in boiler loop pump, a digital temperature display with diagnostics, optional plug-and-play CSD-1 kit, and the included LABOR SAVER manifold. Dimensions are 23-5/8" (W) x 50" (H) x 25-1/2" (D) with a 255 lb ship weight, 4.6 gallons water content, 80 psi ASME rating, boiler supply/return at 1-1/2" and gas at 1" NPT.

The DMG-380 page carries current documents (Rev. A manual MGC-22-380-REV-A dated 2023, spec sheets and submittals through 2025/2026), so this model is recorded as current. The ratings are the US-market figures Dunkirk prints; no Canadian listing was verified on the pages checked on September 9, 2026, so canadianStatus stays 'unknown'. Gas work belongs with a licensed contractor against the DMG-380 IOM.

Best suited to

  • Commercial heating plants needing up to 348 MBH of condensing capacity
  • Floor-standing installations with leveling legs and an 80 psi ASME rating

Applicability and support

Model number
DMG-380
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Dunkirk Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Dunkirk DMG-380 specifications
SpecificationValueNote
Input
Input, maximum379 MBHInput maximum in MBH as printed in the official DMG 240/380 brochure table.
Input, minimum35 MBHInput minimum in MBH as printed in the official DMG 240/380 brochure table.
Output
Heating capacity348 MBHHeating capacity in MBH as printed in the official DMG 240/380 brochure table.
Net water rating303 MBHNet water rating in MBH (piping and pickup allowance of 1.15) as printed in the official DMG 240/380 brochure table.
Efficiency
Thermal efficiency95 %95% thermal efficiency as printed in the official DMG brochure table; the product page rates '95% Thermal Efficiency' with a 10.5:1 turndown.
Venting and air
VentingCoaxial polypropylene 4"/6" or 2-pipe polypropylene 4"Coaxial and 2-pipe diameters as printed in the official DMG 240/380 brochure table.
Physical and connections
Dimensions (W x H x D)23-5/8" (W) x 50" (H) x 25-1/2" (D)Per the official DMG 240/380 brochure table.
Ship weight255 lbPer the official DMG 240/380 brochure table.
Boiler water content4.6 galPer the official DMG 240/380 brochure table.
ASME rating80 psiTested for 50 psi (DMG-240) or 80 psi (DMG-380) ASME, maximum allowable working pressure, per the brochure; the product page lists a 50 psi relief valve.
Heat exchanger316L stainless steelAs printed on the official pages and brochure.
Electrical
Power supply120 V ac, 60 Hz, 1 phase, less than 12 APer the official DMG 240/380 brochure (15 A circuit recommended).
Operating limits and other
Turndown10.5:1Modulation turndown ratio as printed on the product page.
ConnectionsBoiler supply/return 1-1/2"; system supply/return with LABOR SAVER manifold 1-1/2" copper; condensate 3/4" NPT; gas 1" NPTPer the connection/tappings table in the official DMG 240/380 brochure; LABOR SAVER primary/secondary manifold included.
ControlDigital temperature display with diagnostics and programmable settingsHigh limit/electronic ignition control module with a built-in boiler loop pump, direct spark ignition and combination flame sensor/ignitor, per the brochure.

Frequently asked questions

Is the DMG-380 a condensing boiler?

Yes — it is condensing on a 316L stainless steel heat exchanger, rated 95% thermal efficiency with a 10.5:1 turndown ratio.

Is the DMG-380 wall-mounted?

No — the DMG-380 is a compact floor-standing design with leveling legs; the DMG-240 is the wall-hung member of the pair.

What is the DMG-380 rated for?

379 MBH maximum input (35 minimum), 348 MBH heating capacity, a 303 MBH net water rating and an 80 psi ASME rating, per the official brochure table.

Questions about the Dunkirk DMG-380?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate