System 2000 EK2 Frontier 200,000 BTU/hr
The System 2000 EK2 Frontier 200,000 BTU/hr input row is the second EK2 size: 168,000 BTU/hr gross output at 84% AFUE on natural gas (172,000 BTU/hr at 87% on propane) through the EK2 energy converter.
Key figures
- Max input
- 200,000 BTU/hr
- Max CSA output
- —
- AFUE
- 84 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
System 2000 EK2 Frontier 200,000 BTU/hr in practice
The EK2 Frontier 200,000 BTU/hr row is a gas-fired System 2000 configuration built on the EK2 energy converter. The EK1/EK2 gas data sheet prints its input at 200,000 BTU/hr with 168,000 BTU/hr gross output at 84% AFUE on natural gas, or 172,000 BTU/hr at 87% AFUE on propane.
The EK2 converter holds 4 gallons of water and weighs 350 lb; the data sheet describes a 10-foot forced counter-flow flue passage, a 300°F net stack temperature, 3/16-inch pressure-vessel steel throughout, ASME code construction with National Board registration, all welded and threaded connections, a high-temperature combustion chamber, a swing-down front cover and built-in dynamic air elimination. System 2000 combines heat and hot water through the Energy Manager control and a storage tank, with chimney venting standard and a power-vent chimneyless option.
Boilers.ca documents this printed rating row at model level from the data sheet and links the published warranty and brochure. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.
Best suited to
- 200,000 BTU/hr residential heating loads
- Homes wanting heat and hot water from one integrated system
- Larger homes needing the EK2's 4-gallon converter
Applicability and support
- Model number
- Unknown
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Energy Kinetics. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 200,000 BTU/hr | Input per the EK1/EK2 gas product data sheet; the table prints a single fixed input per row with natural-gas and propane columns. |
| Output | ||
| Gross output (natural gas) | 168,000 BTU/hr | Gross output per the data sheet natural-gas column; the propane column prints 172,000 BTU/hr for the same row. |
| Efficiency | ||
| Efficiency (AFUE, natural gas) | 84 % | AFUE per the data sheet natural-gas column; the propane column prints 87% for the same row. |
| Efficiency (AFUE, propane) | 87 % | AFUE per the data sheet propane column for the same input row. |
| Domestic hot water | ||
| Domestic hot water | Integrated system: heat plus domestic hot water from a storage tank using the Energy Manager control | System 2000 is an integrated heat-and-hot-water system per the product page; hot-water output depends on the tank and plate heat exchanger selected with the system, so no single printed DHW rate applies to the converter alone. |
| Venting and air | ||
| Venting | Chimney venting standard; power-vent chimneyless option available | The data sheet describes a 10-foot forced counter-flow flue passage and a 300°F net stack temperature, letting the system vent directly through the wall at ground level when power vented. |
| Physical and connections | ||
| Water content | 4 gal | Water content per the EK1/EK2 gas data sheet feature table (EK1 2½ gal., EK2 4 gal.). |
| Energy converter weight | 350 lb | Energy converter weight per the EK1/EK2 gas data sheet (EK1 270 lb, EK2 350 lb); jacket/insulation adds 90 lb (EK1) or 110 lb (EK2) per the feature table. |
| Operating limits and other | ||
| Construction | 3/16" pressure vessel steel throughout; ASME code construction, National Board registered | All welded and threaded connections, wet-base design, high-temperature combustion chamber and built-in dynamic air elimination per the data sheet feature table. |
| Fuel | Natural gas or propane | The data sheet prints natural-gas and propane columns for every input row. |
| Control | Energy Manager control (5-year warranty, lifetime protection plan) | The Energy Manager maximizes heating efficiency and integrates with the low-mass boiler; warranty per the EK1/EK2 warranty document. |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the EK2 Frontier 200,000 BTU/hr ratings?
200,000 BTU/hr input with 168,000 BTU/hr gross output at 84% AFUE on natural gas, or 172,000 BTU/hr at 87% on propane per the EK1/EK2 gas data sheet.
Does System 2000 make domestic hot water?
Yes — System 2000 is an integrated heat-and-hot-water system: the Energy Manager control and plate heat exchanger charge a storage tank. The converter rating row does not print a standalone DHW rate because output depends on the tank selected.
Questions about the System 2000 EK2 Frontier 200,000 BTU/hr?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- System 2000 EK1 Frontier 80,000 BTU/hrSame series
- System 2000 EK1 Frontier 100,000 BTU/hrSame series
- System 2000 EK1 Frontier 120,000 BTU/hrSame series
- System 2000 EK1 Frontier 150,000 BTU/hrSame series
- System 2000 EK2 Frontier 175,000 BTU/hrSame series
- System 2000 EK2 Frontier 225,000 BTU/hrSame series
- System 2000 EK2 Frontier 250,000 BTU/hrSame series
- System 2000 Frontier series hub
- Buying guide
Sources and verification
- Energy Kinetics — System 2000 Frontier Boilers · accessed September 9, 2026
- Energy Kinetics — EK1 and EK2 (Frontier) gas product data sheet (PDF) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.