Skip to content
Boilers.caby ROMA Heating & Cooling

Fulton · Series

Fulton ENDURA

The ENDURA is Fulton's condensing duplex-stainless firetube boiler in four sizes — EDR-750, EDR-1000, EDR-1500 and EDR-2000 (750,000–2,000,000 BTU/hr) — with a fully-wetted 3-pass design, variable primary flow and low NOx under 20 ppm.

Current seriesunknownNatural gasPropanecommercial

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Natural gas or propane, per the Fulton ENDURA product page.
Venting
Unknown
Models documented
4
Warranty
Not verified

About the ENDURA

Fulton presents the ENDURA as an 'ultra-high efficiency condensing boiler' with a duplex-stainless fully-wetted 3-pass firetube design and variable primary flow. The page prints a size range of 750,000–2,000,000 BTU/hr with the model inventory EDR-750, EDR-1000, EDR-1500 and EDR-2000.

Fulton states the ENDURA's stainless firetube material offers greater strength than conventional 316L (page copy: '19% greater strength') and the line runs low NOx (under 20 ppm). Fuels are natural gas or propane. The page's Specs & Dimensions tab carries an AHRI Thermal Efficiency table whose per-model values are not re-typed in Boilers.ca's research file, so no structured percentage is printed here.

The page's documents tab publishes the brochure, I&O and specification as public PDFs; the brochure is linked from this hub. Fulton's rep finder lists Canada, but no explicit Canadian product statement was found.

Highlights

  • Ultra-high-efficiency condensing boiler, duplex-stainless fully-wetted 3-pass firetube
  • Models EDR-750, EDR-1000, EDR-1500, EDR-2000 (750,000–2,000,000 BTU/hr)
  • Variable primary flow; low NOx (under 20 ppm)
  • Natural gas or propane
  • AHRI Thermal Efficiency table on the page's Specs & Dimensions tab

Models

ENDURA models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
90000–750000 BTU/h
Output (max)
728,250 BTU/h
AFUE

The Fulton ENDURA EDR-750 is a condensing duplex-stainless firetube commercial hydronic boiler rated 750,000 BTU/hr input and 728,250 BTU/hr output at 97.1% thermal efficiency, with 8:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
90000–1000000 BTU/h
Output (max)
953,000 BTU/h
AFUE

The Fulton ENDURA EDR-1000 is a condensing duplex-stainless firetube commercial hydronic boiler rated 1,000,000 BTU/hr input and 953,000 BTU/hr output at 95.3% thermal efficiency, with 11:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
133000–1500000 BTU/h
Output (max)
1,402,500 BTU/h
AFUE

The Fulton ENDURA EDR-1500 is a condensing duplex-stainless firetube commercial hydronic boiler rated 1,500,000 BTU/hr input and 1,402,500 BTU/hr output at 93.5% thermal efficiency, with 11:1 turndown per the official Endura TDS.

Natural gasHeating-only
CurrentCanadian status unknown
Input
133000–2000000 BTU/h
Output (max)
1,874,000 BTU/h
AFUE

The Fulton ENDURA EDR-2000 is a condensing duplex-stainless firetube commercial hydronic boiler rated 2,000,000 BTU/hr input and 1,874,000 BTU/hr output at 93.7% thermal efficiency, with 15:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Fulton ENDURA EDR-750 and Fulton ENDURA EDR-1000 and Fulton ENDURA EDR-1500 and Fulton ENDURA EDR-2000
SpecificationFulton ENDURA EDR-750Fulton ENDURA EDR-1000Fulton ENDURA EDR-1500Fulton ENDURA EDR-2000
Minimum input90,000 BTU/h90,000 BTU/h133,000 BTU/h133,000 BTU/h
Rated input750,000 BTU/h1,000,000 BTU/h1,500,000 BTU/h2,000,000 BTU/h
Rated output728,250 BTU/h953,000 BTU/h1,402,500 BTU/h1,874,000 BTU/h
afue
Turndown8:111:111:115:1
vent-max-3
vent-max-2
Dry weight1,430 lb1,430 lb2,260 lb2,360 lb

Read the full comparison: Fulton ENDURA EDR-750 vs ENDURA EDR-1000

Read the full comparison: Fulton ENDURA EDR-1000 vs ENDURA EDR-1500

Read the full comparison: Fulton ENDURA EDR-1500 vs ENDURA EDR-2000

Read the full comparison: Fulton ENDURA EDR-750 vs EDR-1500

Error codes and alerts

ENDURA alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Fulton ENDURA condensing?

Yes — Fulton's ENDURA is a condensing firetube boiler with a duplex-stainless, fully-wetted 3-pass heat exchanger.

What sizes does the ENDURA come in?

Fulton's model inventory prints EDR-750, EDR-1000, EDR-1500 and EDR-2000, a size range of 750,000–2,000,000 BTU/hr.

Does the ENDURA run on propane?

The Fulton product page lists natural gas and propane. Fuel conversion is a gas-fitting task for a licensed contractor.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.