HTP Elite Ultra 440 — Manager Boiler Missing From Bus

440

InformationalHTP Elite Ultra (ELU) boilers and combis (group fault codes, manual 420010970305)

Manager boiler missing from Bus. Single boiler configured as a follower (if this is a stand alone boiler turn 0.46 to B-SIN); manager boiler miswired (inspect EBUS wiring for damage or shorts - EBUS wiring is polarity sensitive, CN24 pin 11 and 12); manager boiler turned off (ensure power is on for all boilers in cascade); manager boiler not configured correctly (for cascade manager set 0.46 to B-Mas - only one boiler in the cascade may be set to B-Mas, see cascade manual set-up). The table classifies it as Warning (Manual Reset).

Applies to

This communication or network fault code is displayed by the ELU control (group fault codes) on ELU models (ELU-85WBN through ELU-199WCN), as documented in Elite Ultra (ELU) Installation Manual (Table 32 fault codes), 420010970305 / LP-700 (1.24.23) — 150/199 sizes in 420011303900 (420010970305 (LP-700)). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: ELU control (group fault codes). Source manual: 420010970305 (LP-700) (2023-01).

Why a code is not a diagnosis

A communication code involves the link between controls (cascade, remote, sensors on a bus). Another unit being off, a wiring fault or an address conflict can all produce it.

Safe things to observe

  • Check that every appliance in a multi-unit plant has power.
  • Report the code together with any other codes on the system.

Do not

  • Do not re-address or rewire control networks yourself.

How professional service helps

  1. A technician verifies power, wiring and settings across the connected units.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate