Skip to content
Boilers.caby ROMA Heating & Cooling

HTP · Elite Ultra (ELU)

HTP ELU-199WBN

The HTP ELU-199WBN is the 197 MBH-class wall-hung heating-only model of the Elite Ultra line: 19.7 to 197 MBH central-heating input (NG) with no internal DHW, recorded from the CH table printed on the official ELU page.

CurrentCanadian status unknown

Key figures

Max input
197 MBH
Max CSA output
AFUE
Min input
19.7 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP ELU-199WBN in practice

The ELU-199WBN is a wall-hung heating-only unit of HTP's current Elite Ultra (ELU) line — the code reads wall-hung (W), boiler (B), natural gas (N) with liquid-propane conversion kits included. The official model table prints its central-heating input at 19.7 to 197 MBH (natural gas; the LP rows print 19.2 to 192 MBH) and a 'Heating Only' type with 'N/A' in the DHW column.

The page's XtraTech heat exchanger section describes a patent-pending durable stainless steel heating technology with a pipe surface up to 400% larger than conventional designs, and the page claims an 11:1 turndown and up to 96% thermal efficiency when the outdoor sensor is used. The model table itself prints no AFUE, weight or dimension rows, so none are recorded here; the model's installation and operation manual is doc 420010970305 (LP-700 Rev.000, 1.24.23) or 420011303900 (2.28.22) as grouped on the official documents page.

This model is one of the sizes the page says is available with a factory-installed floor-mount kit — 'just add FLKT to the model number when ordering' — so the wall record covers the ELU-150WBN-FLKT/ELU-199WBN-FLKT variants as the same unit. This record is current — the ELU line appears in HTP's current 'Elite Ultra Wall and Floor' navigation with the model table live. Boilers.ca found no official statement of Canadian sales on htproducts.com, so canadianStatus stays 'unknown'; gas and combustion work belongs with a licensed contractor against the model's own I&O manual.

Best suited to

  • Homes whose heat-loss calculation fits inside 197 MBH of heating input
  • Heating-only installs pairing the boiler with an indirect hot-water tank
  • Projects that may want the factory floor-mount kit (add FLKT to the model number)

Applicability and support

Model number
ELU-199WBN
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP ELU-199WBN specifications
SpecificationValueNote
Input
Central-heating input, minimum (natural gas)19.7 MBH19,700 Btu/hr, as printed on the official ELU model table.
Central-heating input, maximum (natural gas)197 MBH197,000 Btu/hr, as printed on the official ELU model table.
Central-heating input, minimum (liquid propane)19.2 MBH19,200 Btu/hr — the 199 models print separate LP rows on the official table.
Central-heating input, maximum (liquid propane)192 MBH192,000 Btu/hr — the 199 models print separate LP rows on the official table.
Efficiency
Thermal efficiency (page claim)Up to 96% with outdoor sensorPage copy: the boiler 'comes with an outdoor sensor that, when used, can provide up to 96% thermal efficiency'. The model table prints no AFUE figure for any ELU model.
Physical and connections
Heat exchangerXtraTech Durable Stainless Steel heat exchangerPage copy: patent-pending XtraTech Durable Stainless Steel Heating Technology with a pipe surface 'up to 400% larger than conventional designs'.
Operating limits and other
FuelNatural gas or propaneThe official page states boiler and combi units 'ship as natural gas units and come standard with liquid propane conversion kits'.
Turndown (page claim)11:1Page copy: 'The Elite Ultra has a 11:1 turndown ratio that limits short cycling' — a page claim, not a per-model printed table value.
Warranty15-year limited warranty when registered onlinePage copy: 'The Elite Ultra is backed by a 15 year limited warranty when registered online' (warranty document lp-707 linked on the page).

Frequently asked questions

Is the HTP ELU-199WBN a combi boiler?

No — the WBN code means wall-hung boiler (heating only): the official table lists its type as 'Heating Only' with N/A in the domestic hot water column, so DHW comes from an indirect tank or another appliance.

Does the ELU-199WBN have a floor version?

Yes — the page states ELU-150WBN, ELU-199WBN and ELU-199WCN are available with a factory-installed floor mount kit: 'just add FLKT to the model number when ordering'.

How is the ELU-199WBN fueled?

The official page states boiler and combi units ship as natural gas units and come standard with liquid propane conversion kits; on the 199 models the table prints separate NG and LP input rows.

Questions about the HTP ELU-199WBN?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate