The Ideal Commodore Floor CB1250F is the smallest Commodore Floor model: 156 to 1,200 MBH input, 97.0% printed thermal efficiency, 8:1 turndown and a 992 lb floor-standing commercial chassis.
Key figures
- Max input
- 1,200 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 156 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Ideal Commodore Floor CB1250F in practice
The CB1250F opens the Commodore Floor line at 1,200 MBH maximum input with a 156 MBH minimum and an 8:1 turndown. Output is 1,200 MBH with a 1,043 MBH net AHRI rating, and the printed efficiency rows are 97.0% thermal and 96.6% combustion. The nameplate size class reads 1250, but the published maximum input row is 1,200 MBH — Boilers.ca keeps the printed row.
The floor-standing chassis measures 55 x 47 x 34 inches and weighs 992 lb, with 11.0 gallons rated water volume. Supply and return connections are 2-1/2-inch Victaulic, gas is 2-inch NPT and vent/air connections are 8-inch/8-inch, with a published vent length of 150 feet. Modbus is standard, BACnet is optional, and the boiler is field-convertible between natural gas and propane.
Cascade capacity reaches 16 boilers. The model is documented by the Commodore Floor installation and service manual, user manual and the CB 1250–2000 submittal sheet. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.
Best suited to
- Commercial plants starting around 1,200 MBH
- Buildings with mechanical-room floor space and 2-1/2-inch Victaulic piping
- Plants planning cascades up to 16 Commodore Floor boilers
Applicability and support
- Model number
- CB1250F
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 156 MBH | Per the official model table. |
| Input, maximum | 1,200 MBH | Per the official model table. |
| Output | ||
| Output | 1,200 MBH | Per the official model table. |
| Net AHRI rating | 1,043 MBH | Per the official model table. |
| Efficiency | ||
| Thermal efficiency | 97 % | Per the official model table. |
| Combustion efficiency | 96.6 % | Per the official model table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only commercial boiler; DHW via a separate water heater or tank | |
| Venting and air | ||
| Flue connection, vent / air | 8 in / 8 in | |
| Vent length | 150 ft | Per the official model table. |
| Physical and connections | ||
| Weight | 992 lb | |
| Width | 55 in | |
| Height | 47 in | |
| Depth | 34 in | |
| Operating limits and other | ||
| Turndown ratio | 8:1 | Per the official model table. |
| Rated volume | 11 gal | Per the official model table. |
| Supply / return water connections | 2-1/2 in Victaulic | Victaulic per the official model table. |
| Gas connection (NPT) | 2 in | |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
What is the input range of the Commodore Floor CB1250F?
156 to 1,200 MBH input with an 8:1 turndown, 1,200 MBH output and a 1,043 MBH net AHRI rating, at 97.0% printed thermal efficiency.
Why is the model called 1250 if the input row says 1,200?
The size class in the model name is 1250, while the official model table prints a 1,200 MBH maximum input row for the CB1250F; Boilers.ca keeps the printed row.
What water connections does the CB1250F use?
2-1/2-inch Victaulic supply and return connections, 2-inch NPT gas and 8-inch/8-inch vent/air, per the official model table.
Questions about the Ideal Commodore Floor CB1250F?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Ideal Heating NA — Commodore Floor Boiler product page and model table · accessed September 9, 2026
- Ideal Heating NA — Commodore Floor CB 1250–2000 submittal sheet (2025-119, rev. 9.8.25) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.