Laars Mini-Therm II JVT-125

The Laars Mini-Therm II JVT-125 is a discontinued 125 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 6 in vent.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBTU/h
Max CSA output
AFUE
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Laars Mini-Therm II JVT-125 in practice

The JVT-125 is the 125 MBTU/h size of Laars' discontinued Mini-Therm II Model JV copper-tube hydronic boiler line, documented with the other JVS and JVT sizes in Document 1025Y. It uses a thermocouple with a continuous burning pilot, and for all JVT models the automatic vent damper's plate hole must never be blocked.

The Figure 1 dimensional table lists the 125 at 16-7/8 in dimension A, 28-3/4 in B, 23-5/8 in C, 22-3/4 in D and 27-1/2 in E, with a 6 in vent, 1-1/4 in water connections and a 1/2 in gas connection. The boiler is natural-draft with a built-in draft diverter and an automatic vent damper, and the manual prints no input, output or AFUE rating table — the size number is the input in MBTU/h and the flow tables use the rating plate's normal input rate.

Best suited to

  • Homes with a heat loss that matches the 125 MBTU/h size
  • Retrofits replacing an existing Model JV boiler with the same footprint
  • Systems that prefer a standing pilot over electronic ignition

Applicability and support

Model number
JVT-125
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Laars Heating Systems. Units are shown with every value; notes flag conflicting sources or missing figures.

Laars Mini-Therm II JVT-125 specifications
SpecificationValueNote
Input
Size / input125 MBTU/hThe 1025Y manual covers sizes 50-225; the size number is the input in MBTU/h and the flow tables use the rating plate's normal input rate.
Venting and air
Vent diameter6 inPer the Figure 1 dimensional table and Section 2.1 vent sizes.
VentingNatural draft with built-in draft diverter and automatic vent damperFor all JVT models the damper plate hole must never be blocked.
Physical and connections
Dimension A16-7/8 inPer the Figure 1 dimensional table; values are printed in inches and cm.
Dimension B28-3/4 inPer the Figure 1 dimensional table.
Dimension C23-5/8 inPer the Figure 1 dimensional table.
Dimension D22-3/4 inPer the Figure 1 dimensional table.
Dimension E27-1/2 inPer the Figure 1 dimensional table.
Water connection1-1/4" NPTPer the Figure 1 dimensional table; values apply to both JVS and JVT.
Gas connection1/2" NPTPer the Figure 1 dimensional table; the 225 natural-gas connection is 3/4 in and propane is 1/2 in.
Operating limits and other
IgnitionThermocouple with continuous burning pilotPer the 1025Y introduction: the JVT has a thermocouple/continuous burning pilot and the JVS has an electronic I.I.D.
FuelNatural gas or propaneNatural gas or propane; the dimensional table prints the gas connection by fuel and the manual's parts sections list fuel-specific parts.

Frequently asked questions

What ignition does the JVT-125 use?

The JVT has a thermocouple and continuous burning pilot; the JVS uses an electronic intermittent ignition device (I.I.D.), per Document 1025Y.

What size is the JVT-125?

The 125 model is the 125 MBTU/h input size, with a 6 in vent, 1-1/4 in water connections and a 1/2 in gas connection per the Figure 1 dimensional table.

Is the Mini-Therm II discontinued?

Yes. Laars' discontinued-documents index lists the Mini-Therm II JVS/JVT installation and operating manual and parts list, and the Document Library files them under Discontinued Documents.

Questions about the Laars Mini-Therm II JVT-125?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.