Laars Heating Systems Mini-Therm JVT (discontinued)

The Mini-Therm II JVT is Laars' discontinued non-condensing residential gas-fired hydronic boiler with a thermocouple and continuous burning pilot, built in sizes 50, 75, 100, 125, 160 and 225 MBTU/h. Laars lists the JVS/JVT installation manual on its discontinued-documents index.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
Unknown
Fuel
Natural gas or propane; the dimensional table's gas connection is 1/2 in NPT, with 3/4 in on the 225 natural-gas size and 1/2 in on propane.
Venting
Natural draft with a built-in draft diverter and an automatic vent damper; vent diameter by size is 4 in (50), 5 in (75/100), 6 in (125/160) and 7 in (225) per Document 1025Y. For all JVT models the damper plate hole must never be blocked.
Models documented
6
Warranty
Not verified

About the Mini-Therm JVT (discontinued)

The Mini-Therm II JVT is the standing-pilot configuration of Laars' Model JV copper-tube hydronic boiler line: a thermocouple with a continuous burning pilot, as against the electronic intermittent ignition (I.I.D.) of the JVS. The 1025Y installation manual covers both configurations at sizes 50-225, and the parts list prints the twelve model columns including JVT-50, JVT-75, JVT-100, JVT-125, JVT-160 and JVT-225.

The six cabinet sizes share the JVS dimensional table: from 13-3/8 by 27-3/4 in on the 50 with a 4 in vent to 25-5/8 by 31-1/2 in on the 225 with a 7 in vent, with 1-1/4 in water connections on every size and 1/2 in gas connections except the 3/4 in natural-gas connection on the 225. All models are natural-draft with a built-in draft diverter and an automatic vent damper; for the JVT the manual requires that the damper plate hole never be blocked, while the JVS receives a metal plug.

The manual prints no input, output or AFUE rating table — the size number is the input in MBTU/h and the flow tables use the rating plate's normal input rate. Laars' discontinued-documents index lists the Mini-Therm II JVS/JVT installation manual and parts list, and the Document Library files them under Discontinued Documents.

Highlights

  • Sizes 50, 75, 100, 125, 160 and 225 MBTU/h; models JVT-50 through JVT-225
  • Thermocouple and continuous burning pilot versus the JVS's electronic ignition
  • Natural draft with built-in draft diverter and automatic vent damper
  • Vent diameter 4 in (50) to 7 in (225); 1-1/4 in water connections
  • JVT damper plate hole must never be blocked per Document 1025Y
  • Laars discontinued-documents index: Mini-Therm II JVS, JVT manual and parts list

Models

Mini-Therm JVT (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

Laars Heating Systems

Laars Mini-Therm II JVT-50

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-50 is a discontinued 50 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 4 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVT-75

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-75 is a discontinued 75 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 5 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVT-100

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-100 is a discontinued 100 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 5 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVT-125

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-125 is a discontinued 125 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 6 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVT-160

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-160 is a discontinued 160 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 6 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVT-225

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Mini-Therm II JVT-225 is a discontinued 225 MBTU/h non-condensing residential hydronic boiler with a thermocouple and continuous burning pilot, 1-1/4 in water connections and a 7 in vent.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Laars Mini-Therm II JVT-50 and Laars Mini-Therm II JVT-75 and Laars Mini-Therm II JVT-100 and Laars Mini-Therm II JVT-125 and Laars Mini-Therm II JVT-160 and Laars Mini-Therm II JVT-225
SpecificationLaars Mini-Therm II JVT-50Laars Mini-Therm II JVT-75Laars Mini-Therm II JVT-100Laars Mini-Therm II JVT-125Laars Mini-Therm II JVT-160Laars Mini-Therm II JVT-225
input-min——————
Size / input50 MBTU/h75 MBTU/h100 MBTU/h125 MBTU/h160 MBTU/h225 MBTU/h
output-max——————
afue——————
turndown——————
vent-max-3——————
vent-max-2——————
weight——————

Read the full comparison: Laars Mini-Therm II JVT-50 vs JVT-75 →

Read the full comparison: Laars Mini-Therm II JVT-75 vs JVT-100 →

Read the full comparison: Laars Mini-Therm II JVT-100 vs JVT-125 →

Read the full comparison: Laars Mini-Therm II JVT-125 vs JVT-160 →

Error codes and alerts

Mini-Therm JVT (discontinued) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Services for Laars Heating Systems boilers

Frequently asked questions

What is the difference between the Mini-Therm JVT and JVS?

The JVT has a thermocouple and continuous burning pilot, while the JVS has an electronic intermittent ignition device (I.I.D.). The JVT's automatic vent damper plate hole must never be blocked, per Document 1025Y.

What sizes did the Mini-Therm JVT come in?

The manual covers sizes 50-225, and the parts list prints the JVT model columns at 50, 75, 100, 125, 160 and 225 MBTU/h.

Is the Mini-Therm JVT discontinued?

Yes. Laars' discontinued-documents index lists the Mini-Therm II JVS/JVT install and operating manual and parts list, and the Document Library files them under Discontinued Documents.