Navien NCB-150E

The Navien NCB-150E is a previous-generation wall-hung condensing combi from the discontinued NCB-E series: 12 to 60 MBH heating input, 56 MBH capacity at 95.0% AFUE, and DHW input to 120,000 BTU/h.

DiscontinuedHistorically in Canada

Key figures

Max input
60 MBH
Max CSA output
AFUE
95 %
Min input
12 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Navien NCB-150E in practice

The NCB-150E is one of the four NCB-E combis that preceded the current NCB-H line; Navien lists the series (NCB-150E, 180E, 210E and 240E) under Discontinued Products on both official sites. The NCB-E specification sheet prints 12–60 MBH heating input with 56 MBH heating capacity, a 49 MBH net AHRI water rating and 95.0% AFUE.

Domestic hot water is produced on demand inside the combi: the spec sheet prints DHW input of 12,000–120,000 BTU/h and 2.6 GPM at a 77°F (43°C) temperature rise with a 0.5 GPM minimum. The unit weighs 66 lb in a 17 × 28 × 12 in cabinet with 1" NPT heating connections and 3/4" NPT DHW and gas connections, on 12 – 30 psi hydronic pressure (15–150 psi DHW).

The NCB-E generation shares several error-code numerals with the NCB-H line — E205, E218, E407, E421, E439, E517, E740, E777 and E782 among them — but codes were added and removed between generations, and the NCB-E installation manual carries no error table, so diagnosis for an NCB-E should follow the NCB-E service manual rather than the newer H-series literature.

Best suited to

  • Owners of an existing NCB-E combi looking up its printed ratings
  • Understanding the differences between the NCB-E generation and today's NCB-H
  • Sourcing the correct generation of service literature for an older combi

Applicability and support

Model number
NCB-150E
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.

Navien NCB-150E specifications
SpecificationValueNote
Input
Heating input, minimum12 MBHPer the NCB-E Specification Sheet.
Heating input, maximum60 MBHPer the NCB-E Specification Sheet.
Output
Heating capacity56 MBHDOE test basis, per the NCB-E Specification Sheet.
Net AHRI water rating49 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %AFUE per the NCB-E Specification Sheet.
Domestic hot water
DHW input, minimum12 MBH12,000 BTU/h.
DHW input, maximum120 MBH120,000 BTU/h.
DHW flow rate at 77°F (43°C) rise2.6 GPMPer the NCB-E Specification Sheet; minimum DHW flow 0.5 GPM.
DHW connections3/4" NPTDHW inlet and outlet, 3/4" NPT.
Venting and air
Venting2" or 3" PVC, CPVC, polypropylene; 2" or 3" special gas vent Type BH (Class III A/B/C)Forced-draft direct vent per the official specifications.
Physical and connections
Weight66 lbAs printed in the official document.
Width17 in
Height28 in
Depth12 in
Heating connections1" NPTSupply and return.
Gas connection3/4" NPT
Operating limits and other
FuelNatural gas or propaneRatings are the same for natural gas models converted to propane use; field conversion is licensed gas work.
Hydronic water pressure12 – 30 psiDHW side rated 15–150 psi.

Frequently asked questions

What are the ratings of the Navien NCB-150E?

The NCB-E specification sheet prints 12–60 MBH heating input, 56 MBH heating capacity, a 49 MBH net AHRI water rating and 95.0% AFUE, with DHW input of 12,000–120,000 BTU/h and 2.6 GPM at a 77°F rise.

Is the Navien NCB-150E still sold?

No. The NCB-E series is on Navien's discontinued-products list; the current Canadian combi lines are the NCB-H and NFC-H series. Official model pages and manuals remain online for existing owners.

Do NCB-E and NCB-H error codes match?

Only partly. Some codes are shared, but numerals were added and removed between generations and the same code can mean something different. Read each code against the NCB-E service manual (Ver 1.4, Oct 2015) for an NCB-E unit.

Questions about the Navien NCB-150E?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate