Navien NHB-110H

The Navien NHB-110H is the 110 MBH compact boiler of the NHB-H series: 10 to 110 MBH input at 95.0% AFUE with 11:1 turndown per the quick facts, stepping up to 80 lb in the same short cabinet.

CurrentSold in Canada

Key figures

Max input
110 MBH
Max CSA output
AFUE
95 %
Min input
10 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Navien NHB-110H in practice

The NHB-110H takes the compact NHB-H cabinet from 73 to 80 lb and the firing ceiling from 80 to 110 MBH, with its minimum fire rising only slightly to 10 MBH. Navien's quick facts list an 11:1 turndown for this model, so it can still track mild-weather loads despite the larger maximum.

It is the middle size of the NHB-H line and suits detached homes with radiators or in-floor loops whose heat-loss calculation lands near 100 MBH. Heating-only with no DHW codes, it connects on 1" NPT heating fittings, runs on 12 to 30 psi system pressure and vents in 2" or 3" PVC to 65 or 150 equivalent feet per the installation manual.

Best suited to

  • Detached homes whose heat-loss calculation sits between 80 and 110 MBH
  • Homes pairing a compact boiler with an indirect tank for hot water
  • Owners who want an 80 lb wall-hung unit instead of a heavier mid-size boiler

Applicability and support

Model number
NHB-110H
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.

Navien NHB-110H specifications
SpecificationValueNote
Input
Heating input, minimum10 MBHSpace-heating input.
Heating input, maximum110 MBHSpace-heating input.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the installation manual.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tank or separate appliance
Venting and air
VentingPVC, CPVC or approved polypropylene; 2" or 3"Canada: plastic venting must meet ULC S636 where required.
Max. equivalent vent length, 2"65 ft
Max. equivalent vent length, 3"150 ft
Physical and connections
Weight80 lb36 kg; per the installation manual.
Width17.3 in
Height23.8 in
Depth12.8 in
Gas connection3/4" NPT
Heating water connections1" NPT
Operating limits and other
FuelNatural gas or propaneSeparate Navien ratings per fuel.
Altitude rating10,100 ftPer installation manual.
System water pressure12 – 30 psi

Frequently asked questions

What is the firing range of the NHB-110H?

10,000 to 110,000 BTU/h of input per the installation manual, rated 95.0% AFUE, with 11:1 turndown listed in Navien's quick facts.

Does the NHB-110H fit where the NHB-80H fit?

Yes. The cabinet is the same 17.3 x 12.8 x 23.8 in; the 110H is 7 lb heavier (80 lb against 73 lb).

Is the NHB-110H available for propane?

Yes. Navien lists the NHB-H series for natural gas or propane with separate ratings per fuel; conversion and setup are licensed gas-fitting work.

Questions about the Navien NHB-110H?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate