Navien
Navien NHB-80H
- Input
- 8–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Navien NHB-80H is the 80 MBH member of the compact NHB-H series: 8 to 80 MBH input at 95.0% AFUE, keeping the 8 MBH minimum fire and the 73 lb, 23.8-inch-tall cabinet of the NHB-55H.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
The NHB-80H and NHB-110H part ways at both ends of the firing range: minimum fire rises from 8 to 10 MBH and the ceiling from 80 to 110 MBH, the cabinet gains 7 lb (73 to 80 lb) while staying 23.8 inches tall, and the quick-facts turndown steps from 10:1 to 11:1.
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Navien NHB-80H | Navien NHB-110H |
|---|---|---|
| Heating input, minimum | 8 MBH | 10 MBH |
| Heating input, maximum | 80 MBH | 110 MBH |
| Efficiency (AFUE) | 95 % | 95 % |
| Weight | 73 lb | 80 lb |
| Max. equivalent vent length, 2" | 65 ft | 65 ft |
| Max. equivalent vent length, 3" | 150 ft | 150 ft |
| Domestic hot water | Heating-only boiler; domestic hot water via an indirect tank or separate appliance | Heating-only boiler; domestic hot water via an indirect tank or separate appliance |
Both are heating-only NHB-H boilers rated 95.0% AFUE in the compact cabinet, and both handle domestic hot water through an indirect tank or separate appliance. The visible differences are capacity and the small weight step between the 73 lb 80H and the 80 lb 110H.
The 110H fires 10 to 110 MBH against the 80H's 8 to 80 MBH. Its minimum fire is 2 MBH higher, so in a very low-load home the 80H tracks shoulder-season demand a little more closely, while the 110H's extra 30 MBH of ceiling covers homes whose loads sit near 100 MBH.
Venting (2" to 65 ft or 3" to 150 ft), connections and the 17.3 x 12.8 x 23.8 in footprint are shared, so the step costs nothing in the mechanical-room plan beyond the 7 lb weight difference. The heat-loss calculation plus any indirect-tank recovery demand decides which ceiling the home actually needs.
Navien
The Navien NHB-80H is the 80 MBH member of the compact NHB-H series: 8 to 80 MBH input at 95.0% AFUE, keeping the 8 MBH minimum fire and the 73 lb, 23.8-inch-tall cabinet of the NHB-55H.
Navien
The Navien NHB-110H is the 110 MBH compact boiler of the NHB-H series: 10 to 110 MBH input at 95.0% AFUE with 11:1 turndown per the quick facts, stepping up to 80 lb in the same short cabinet.
80 lb against 73 lb, per the installation manual. The cabinet dimensions are unchanged.
The NHB-80H fires 8,000 to 80,000 BTU/h and the NHB-110H fires 10,000 to 110,000 BTU/h, both rated 95.0% AFUE.
When the heat-loss calculation shows the home can need more than 80 MBH on a design day. Its higher 10 MBH minimum fire is the small price of that ceiling.
A consultation includes a heat-loss review so the size is right the first time.