Skip to content
Boilers.caby ROMA Heating & Cooling

Navien · Series

Navien NFB-H Boiler

The NFB-H is Navien's heating-only condensing boiler series for Canada: the NFB-175H and NFB-200H, rated 95.0% AFUE, designed to work with an external tank for domestic hot water and carrying no DHW error codes because hot water is not produced inside the unit.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas / Propane
Venting
2" or 3" venting; PVC is the default pipe material per the installation manual, with approved polypropylene and stainless steel options; up to 65 equivalent ft in 2" and 150 in 3".
Models documented
2
Warranty
Not verified

95.0% AFUE across the series per the installation manual.

About the NFB-H Boiler

The NFB-H is a wall-hung condensing boiler with no integrated hot-water production: domestic hot water comes from an indirect tank or a separate appliance, so there is no DHW plumbing and no DHW code set in the unit's error tables. The two Canadian models, NFB-175H and NFB-200H, fire from 13,300 BTU/h to 175,000 or 199,900 BTU/h at 95.0% AFUE.

Heating connections are 1 1/4" NPT, the boiler holds 4.5 USG of water and weighs 121 lb empty (148 lb with water), per the installation manual. Navien's quick facts list turndown of about 13.2:1 on the NFB-175H and 15:1 on the NFB-200H.

Venting is 2" or 3" with PVC as the default pipe material per the installation manual, plus approved polypropylene and stainless steel systems, to 65 or 150 equivalent feet. The control shows E0xx codes that Navien documents in the service manual; Boilers.ca reads each code against the NFB-H generation's own manual.

Highlights

  • Heating-only condensing boiler; hot water via an external tank or separate appliance
  • NFB-175H and NFB-200H, both 95.0% AFUE
  • 1 1/4" NPT heating connections; 4.5 USG water content
  • No DHW error codes, because the unit produces no domestic hot water
  • Quick facts list up to 15:1 turndown on the NFB-200H

Models

NFB-H Boiler models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
13.3–175 MBH
Output (max)
—
AFUE
95 %

The Navien NFB-175H is a heating-only condensing boiler firing 13.3 to 175 MBH at 95.0% AFUE, with 1 1/4" NPT heating connections and no integrated hot-water production — hot water comes from an external tank.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
13.3–199.9 MBH
Output (max)
—
AFUE
95 %

The Navien NFB-200H is the largest NFB-H heating-only boiler: 13.3 to 199.9 MBH of input at 95.0% AFUE with 15:1 turndown per the quick facts, sharing the 121 lb cabinet and 1 1/4" NPT connections of the NFB-175H.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Navien NFB-175H and Navien NFB-200H
SpecificationNavien NFB-175HNavien NFB-200H
Heating input, minimum13.3 MBH13.3 MBH
Heating input, maximum175 MBH199.9 MBH
output-max——
Efficiency (AFUE)95 %95 %
turndown——
Max. equivalent vent length, 3"150 ft150 ft
Max. equivalent vent length, 2"65 ft65 ft
Weight121 lb121 lb

Read the full comparison: Navien NFB-175H vs NFB-200H →

Read the full comparison: Viessmann Vitodens 100-W B1HE-199 vs Navien NFB-200H →

Read the full comparison: Viessmann Vitodens 200-W B2HE-150 vs Navien NFB-175H →

Read the full comparison: Navien NFB-200H vs NTI Trinity TFTN199 →

Read the full comparison: Triangle Tube Prestige Solo 155 vs Navien NFB-175H →

Error codes and alerts

NFB-H Boiler alerts

  • E001front-panel display
  • E003front-panel display
  • E004front-panel display
  • E012front-panel display
  • E016front-panel display
  • E030front-panel display
  • E031front-panel display
  • E046front-panel display
  • E047front-panel display
  • E060front-panel display
  • E109front-panel display
  • E110front-panel display
  • E205front-panel display
  • E218front-panel display
  • E278front-panel display
  • E279front-panel display
  • E291front-panel display
  • E302front-panel display
  • E352front-panel display
  • E353front-panel display
  • E480front-panel display
  • E515front-panel display
  • E517front-panel display
  • E594front-panel display
  • E615front-panel display
  • E736front-panel display
  • E740front-panel display
  • E762front-panel display
  • E777front-panel display
  • E782front-panel display
  • E784front-panel display
  • E786front-panel display
  • E788front-panel display

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Does the NFB-H produce domestic hot water?

No. The NFB-H is a heating-only boiler. Domestic hot water is handled by an indirect tank or a separate appliance connected to the system, which is why the NFB-H's error tables carry no DHW codes.

What sizes does the NFB-H come in?

Navien Canada lists two models: the NFB-175H fires 13,300 to 175,000 BTU/h and the NFB-200H fires 13,300 to 199,900 BTU/h, both rated 95.0% AFUE.

Can the NFB-H be vented in PVC?

Yes. The installation manual states PVC is the default vent pipe material for the NFB-H, with approved polypropylene and stainless steel vent systems also listed; maximum length is 65 equivalent feet in 2" or 150 in 3".

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.