The Navien NFB-200H and NTI Trinity TFTN199 are both 95% AFUE, roughly 199 MBH-input heating-only condensing boilers, but they occupy very different cabinets: the NFB-200H fires 13.3 to 199.9 MBH from a 121 lb, 27.6-inch-tall unit, while the TFTN199 runs 19.9 to 199 MBH at 140 lb with water in a 34.1-inch cabinet. Both vent 2" or 3" and take an indirect tank; heat-loss calculation decides size.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NFB-200H and NTI Trinity TFTN199
SpecificationNavien NFB-200HNTI Trinity TFTN199
Heating input, minimum13.3 MBH19.9 MBH
Heating input, maximum199.9 MBH199 MBH
Efficiency (AFUE)95 %95 %
FuelNatural gas or propaneNatural gas or propane
Weight121 lb140 lb
Width17.3 in19.875 in
Height27.6 in34.125 in
Depth17.3 in18.75 in
Max. equivalent vent length, 2"65 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
Gas connection3/4" NPT3/4" NPT
Heating water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tank or separate applianceHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers are heating-only condensing units rated 95% AFUE on natural gas or propane, and both reach the 199 MBH mark: Navien at 199.9 MBH and NTI at 199 MBH of input. The low-fire numbers give Navien an edge in part-load behaviour — 13.3 MBH against the TFTN199's 19.9 MBH — which shows up as longer steady runs in mild weather rather than a headline difference.

The cabinets could hardly be more different for the same capacity: the NFB-200H is 17.3 inches wide, 27.6 inches high and 17.3 inches deep, weighing 121 lb (148 lb with water), while the TFTN199 measures 19.875 by 34.125 by 18.75 inches and weighs 140 lb with water. A low-ceiling mechanical room can rule out the taller NTI regardless of performance.

Venting and connections converge: both allow 2" runs (65 feet per side for Navien, 100 feet for NTI) and 3" runs to 150 feet per side, and both use 3/4" NPT gas with 1 1/4" NPT heating connections. Both need an indirect tank for domestic hot water, and both are matched to the home by a heat-loss calculation — the 199 MBH class is only right for buildings that genuinely load it.

CurrentSold in Canada
Input
13.3–199.9 MBH
Output (max)
—
AFUE
95 %

The Navien NFB-200H is the largest NFB-H heating-only boiler: 13.3 to 199.9 MBH of input at 95.0% AFUE with 15:1 turndown per the quick facts, sharing the 121 lb cabinet and 1 1/4" NPT connections of the NFB-175H.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only

Frequently asked questions

Which of these 199 MBH boilers modulates lower?

The Navien NFB-200H drops to 13.3 MBH minimum input versus 19.9 MBH on the NTI TFTN199, giving it steadier low-load running.

Are their cabinets interchangeable in a retrofit?

No. The NFB-200H is 27.6 inches tall versus 34.125 inches for the TFTN199, so ceiling height and service clearance can decide the model.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate