Skip to content
Boilers.caby ROMA Heating & Cooling

New Yorker Boiler · CG-F

New Yorker CG-F CG30F

The New Yorker CG-F CG30F is the second size sharing the 14-inch cabinet and 4-inch vent: 70 MBH input with 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 4".

CurrentCanadian status unknown

Key figures

Max input
70 MBH
Max CSA output
AFUE
84 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

New Yorker CG-F CG30F in practice

The CG-F CG30F is a cast-iron, chimney-vented gas water boiler rated at 70 MBH input. Its row in the CG-F specification table prints 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating (1.15 piping and pickup allowance) at 84.0% AFUE, with a 4" vent, a 14"-wide cabinet and an approximate shipping weight of 254 lb.

Standard equipment includes an insulated steel jacket, integral draft diverter, damper and connector, an integrated boiler control with three-digit status readout and the energy-saving thermal purge, an integral LWCO, a step-opening redundant gas valve, spark ignition with continuous retry, a circulator and a resettable blocked vent switch. Supply and return connections are 1-1/4 inches with a 1/2" gas valve, and the boilers ship with a 30 PSI relief valve at 50 PSI MAWP.

Boilers.ca documents this size at model level from the specification sheet. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 70 MBH residential heat-loss loads
  • Replacement installations with an existing chimney
  • Owners wanting the thermal purge and integral LWCO in the base control

Applicability and support

Model number
CG30F
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.

New Yorker CG-F CG30F specifications
SpecificationValueNote
Input
Input70 MBHInput per the CG-F specification table (certified to 2,000 ft; ratings decrease 2.5% per 1,000 ft above that, altitude kits required above 5,400 ft).
Output
DOE heating capacity59 MBHDOE heating capacity per the CG-F specification table.
Net AHRI water rating51 MBHNet AHRI water rating per the CG-F specification table, based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)84 %84.0% AFUE per the CG-F specification table; the page headline is 84% AFUE.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent diameter4"Vent diameter per the CG-F specification table; the boiler is chimney vented with an integral draft diverter, damper and connector included.
VentingChimney vented with integral draft diverterIntegral draft diverter, damper and connector included; resettable blocked vent switch standard.
Physical and connections
Approx. shipping weight254 lbApproximate shipping weight per the CG-F specification table.
Dimensions (width × height × depth)14" × 40" × 32"CG-F dimension table values; height and depth are common across the line.
Supply/return connections1-1/4" supply and 1-1/4" returnWater connection sizes per the CG-F specification table.
Gas valve connection1/2"Gas valve connection per the CG-F specification table.
Operating limits and other
ControlIntegrated boiler control with thermal purge and integral LWCOIntegrated control with user-friendly interface, energy-saving thermal purge, integral LWCO (IDL-1200) and an additional pump relay per the specification sheet.
FuelNatural gas ('N' suffix) or LP gas ('L' suffix)Add suffix 'N' for natural gas or 'L' for LP gas models per the CG-F specification table note.

Manuals

Alerts documented for this model

None documented yet.

Services

Frequently asked questions

What are the CG-F CG30F's ratings?

70 MBH input, 59 MBH DOE heating capacity, a 51 MBH net AHRI water rating and 84.0% AFUE with a 4" vent per the CG-F specification table.

Does the CG-F CG30F need a chimney?

Yes — the CG-F is chimney vented with an integral draft diverter, damper and connector; this size lists a 4" vent diameter.

Questions about the New Yorker CG-F CG30F?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate