New Yorker Boiler · Series

New Yorker Boiler CG-F

The New Yorker CG-F is the brand's cast-iron, chimney-vented gas water boiler at 84% AFUE, sold in eight sizes CG20F through CG90F covering 38–280 MBH input with an integrated boiler control featuring the energy-saving thermal purge, integral LWCO and an additional pump relay.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84% AFUE
Fuel
Add suffix 'N' for natural gas or suffix 'L' for LP gas models per the CG-F ratings table note.
Venting
Chimney vented with an integral draft diverter, damper and connector included; vent diameter steps from 4" (CG20F/CG30F) to 8" (CG90F) per the CG-F specification table. The CG20F is not for use above 2,000 feet.
Models documented
8

All eight CG-F rows print 84.0% AFUE in the product specification table.

About the CG-F

The CG-F is New Yorker's efficient gas-fired cast-iron water boiler, published on the official site with an 84% AFUE headline and a size range of 38–280 MBH in eight sizes. The product page and specification sheet describe chimney venting with an integral draft diverter, damper and connector included; an integrated boiler control with a user-friendly interface, the energy-saving 'thermal purge' feature that circulates residual warm water through the heating system before firing the boiler, an integral LWCO (IDL-1200) and an additional pump relay; natural or LP gas operation; a cast-iron heat exchanger meeting the ASME Boiler and Pressure Vessel Code; metal section connectors; a step-opening gas valve for smooth and quiet start-up; and a lifetime limited warranty.

The CG-F specification table prints the complete ratings: CG20F (38 MBH input, 32 MBH DOE heating capacity, 28 MBH net AHRI water, 84.0% AFUE, 4" vent, 202 lb), CG30F (70/59/51 MBH, 84.0%, 4", 254 lb), CG40F (105/88/77 MBH, 84.0%, 5", 304 lb), CG50F (140/117/102 MBH, 84.0%, 6", 357 lb), CG60F (175/146/127 MBH, 84.0%, 6", 405 lb), CG70F (210/176/153 MBH, 84.0%, 7", 462 lb), CG80F (245/205/178 MBH, 84.0%, 7", 518 lb) and CG90F (280/234/203 MBH, 84.0%, 8", 564 lb). Ratings are based on certification up to 2,000 feet (the CG20F is not for use above 2,000 ft), decrease 2.5% per 1,000 feet above that, and require altitude kits above 5,400 feet; net AHRI water ratings use a 1.15 piping and pickup allowance and all boilers ship with a 30 PSI relief valve at 50 PSI MAWP.

Supply and return connections are 1-1/4 inches with a 1/2-inch gas valve on the smaller sizes and 3/4-inch on the CG70F–CG90F. Boilers.ca documents all eight sizes at model level from the specification sheet; no official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current New Yorker cast-iron gas water boiler: CG20F to CG90F (eight sizes)
  • 84.0% AFUE on every row; 38–280 MBH input
  • DOE heating capacity 32–234 MBH; net AHRI water 28–203 MBH at 1.15 allowance
  • Chimney vented with integral draft diverter, damper and connector included
  • Integrated boiler control with thermal purge, integral LWCO and pump relay
  • Natural gas ('N' suffix) or LP gas ('L' suffix) models
  • Model-level pages published on Boilers.ca; product specifications linked here

Lifetime limited warranty per the CG-F specification sheet; see the installing contractor for warranty information.

Models

CG-F models

One canonical page per model with input, output and efficiency kept separate.

New Yorker Boiler

New Yorker CG-F CG20F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG20F is the smallest CG-F size, not for use above 2,000 feet: 38 MBH input with 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 4".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG30F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG30F is the second size sharing the 14-inch cabinet and 4-inch vent: 70 MBH input with 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 4".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG40F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG40F is the third size, stepping to a 5-inch vent: 105 MBH input with 88 MBH DOE heating capacity and a 77 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 5".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG50F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG50F is the mid-size CG-F with a 6-inch vent: 140 MBH input with 117 MBH DOE heating capacity and a 102 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 6".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG60F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG60F is the fifth size, sharing the 6-inch vent with the CG50F: 175 MBH input with 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 6".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG70F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG70F is the first size with a 3/4-inch gas valve and 7-inch vent: 210 MBH input with 176 MBH DOE heating capacity and a 153 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 7".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG80F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG80F is the second-largest CG-F size: 245 MBH input with 205 MBH DOE heating capacity and a 178 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 7".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG90F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG90F is the largest CG-F size with an 8-inch vent: 280 MBH input with 234 MBH DOE heating capacity and a 203 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 8".

Natural gasPropaneHeating-only

Compare models in this series

Comparison of New Yorker CG-F CG20F and New Yorker CG-F CG30F and New Yorker CG-F CG40F and New Yorker CG-F CG50F and New Yorker CG-F CG60F and New Yorker CG-F CG70F and New Yorker CG-F CG80F and New Yorker CG-F CG90F
SpecificationNew Yorker CG-F CG20FNew Yorker CG-F CG30FNew Yorker CG-F CG40FNew Yorker CG-F CG50FNew Yorker CG-F CG60FNew Yorker CG-F CG70FNew Yorker CG-F CG80FNew Yorker CG-F CG90F
input-min————————
Input38 MBH70 MBH105 MBH140 MBH175 MBH210 MBH245 MBH280 MBH
output-max————————
Efficiency (AFUE)84 %84 %84 %84 %84 %84 %84 %84 %
turndown————————
vent-max-3————————
vent-max-2————————
Approx. shipping weight202 lb254 lb304 lb357 lb405 lb462 lb518 lb564 lb

Read the full comparison: New Yorker CG-F CG20F vs CG30F →

Read the full comparison: New Yorker CG-F CG30F vs CG40F →

Read the full comparison: New Yorker CG-F CG40F vs CG50F →

Read the full comparison: New Yorker CG-F CG50F vs CG60F →

Error codes and alerts

CG-F alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What does the CG-F thermal purge feature do?

The specification sheet describes it as circulating residual warm water in the heating system prior to firing the boiler, an energy-saving feature that reduces unnecessary burner cycles.

What sizes does the CG-F come in?

Eight sizes: CG20F through CG90F, covering 38, 70, 105, 140, 175, 210, 245 and 280 MBH input at 84.0% AFUE per the CG-F specification table.

Can the CG-F be installed above 2,000 feet?

The table's ratings are certified to 2,000 feet and decrease 2.5% per 1,000 feet above that; altitude kits are required above 5,400 feet, and the CG20F is not for use above 2,000 feet.