Skip to content
Boilers.caby ROMA Heating & Cooling

New Yorker Boiler · CGS-C

New Yorker CGS-C CGS80C

The New Yorker CGS-C CGS80C is the largest CGS-C at 82.2% AFUE: 241 MBH input with 199 MBH DOE heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, chimney vented with a 7" flue collar.

CurrentCanadian status unknown

Key figures

Max input
241 MBH
Max CSA output
AFUE
82.2 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

New Yorker CGS-C CGS80C in practice

The CGS-C CGS80C is a cast-iron gas-fired steam boiler rated at 241 MBH input. Its row in the CGS-C specification table prints 199 MBH DOE heating capacity, a 149 MBH AHRI net steam rating at a 1.333 piping and pickup allowance, 621 steam square feet and 82.2% AFUE, with a 7" flue collar and an approximate ship weight of 690 lb.

The boiler ships fully packaged with an insulated jacket, built-in draft diverter, pressure limit, 15 PSI safety valve, Honeywell gas valve, probe-type LWCO, steam pressure gauge, flame roll-out switch, blocked vent switch, vent damper and drain valve, and the optional near-boiler piping kit (P/N 850095U) is available for 3–6 section boilers. Ratings are for sea level to 2,000 feet and reduce 4% per 1,000 feet above that, and LP conversion kits are available only for installations up to 2,000 feet.

Boilers.ca documents this size at model level from the specification sheet and links the published I&O manual. Steam, gas and venting work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 241 MBH residential steam loads
  • Homes with an existing chimney
  • Systems needing about 621 square feet of steam radiation

Applicability and support

Model number
CGS80C
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.

New Yorker CGS-C CGS80C specifications
SpecificationValueNote
Input
Input241 MBHInput per the CGS-C specification table (sea level to 2,000 ft; reduce 4% per 1,000 ft above that).
Output
DOE heating capacity199 MBHDOE heating capacity per the CGS-C specification table.
AHRI net steam rating149 MBHAHRI net steam rating per the CGS-C specification table, based on a piping and pickup allowance of 1.333.
Steam square feet621 sq ftSteam square feet per the CGS-C specification table.
Efficiency
Efficiency (AFUE)82.2 %AFUE per the CGS-C specification table; the page headline is 'Up to 82.2% AFUE'.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Flue collar diameter7"Flue collar diameter per the CGS-C specification table; the boiler has a built-in draft diverter that fits in low spaces.
VentingChimney vented with built-in draft diverterBuilt-in draft diverter fits in low spaces; vent damper and blocked vent switch standard.
Physical and connections
Approx. ship weight690 lbApproximate ship weight per the CGS-C specification table.
Supply/return connections2" supply and 2" returnSteam connection sizes per the CGS-C specification sheet; probe-type LWCO and 15 PSI safety valve standard.
Operating limits and other
ControlFully packaged with pressure limit, probe-type LWCO and vent damperStandard features include pressure limit, 15 PSI safety valve, Honeywell gas valve, probe-type LWCO, steam pressure gauge, flame roll-out switch and drain valve.
FuelNatural gas or LP gas (conversion kit)Gas-to-LP conversion kits are listed by model (P/N 105801-03 through 105801-08), available for installations up to 2,000 feet only.

Frequently asked questions

What are the CGS-C CGS80C's ratings?

241 MBH input, 199 MBH DOE heating capacity, a 149 MBH AHRI net steam rating (621 sq ft) and 82.2% AFUE with a 7" flue collar per the CGS-C specification table.

Are steam boilers sold in water configurations?

No — the CGS-C is a steam series; New Yorker's water boilers are the CG-F (chimney vented) and PVCG-C (power vented) series.

Questions about the New Yorker CGS-C CGS80C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.