Skip to content
Boilers.caby ROMA Heating & Cooling

New Yorker Boiler · Series

New Yorker Boiler CGS-C

The New Yorker CGS-C is the brand's gas-fired cast-iron steam boiler, sold fully assembled in six sizes CGS30C through CGS80C covering 69–241 MBH input at up to 82.2% AFUE with a built-in draft diverter, probe-type LWCO and an optional pre-cut near-boiler piping kit.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
82.2% AFUE
Fuel
Natural or LP gas with conversion kit: the specification sheet lists gas-to-LP conversion kits by model (P/N 105801-03 through 105801-08), available for installations up to 2,000 feet only.
Venting
Chimney vented with a built-in draft diverter that fits in low spaces; flue collar diameter steps from 4" (CGS30C) to 7" (CGS70C/CGS80C) per the specification table. Ratings are for sea level to 2,000 feet; reduce 4% per 1,000 feet above that.
Models documented
6

Rows print 82.0% (CGS30C–CGS50C), 82.1% (CGS60C/CGS70C) and 82.2% (CGS80C); the page headline is 'Up to 82.2% AFUE'.

About the CGS-C

The CGS-C is New Yorker's efficient gas-fired steam boiler, published on the official site with an 'Up to 82.2% AFUE' headline and a 69–241 MBH range across six sizes. The product page describes a built-in draft diverter that fits in low spaces, natural or LP gas operation with a conversion kit, electronic ignition, stainless-steel burners, a cast-iron heat exchanger meeting the ASME Boiler and Pressure Vessel Code, metal section connectors, fully assembled shipment and an optional near-boiler piping kit (part number 850095U, available for 3–6 section boilers). The specification sheet lists a fully packaged boiler with insulated jacket, pressure limit, 15 PSI safety valve, Honeywell gas valve, probe-type LWCO, steam pressure gauge, flame roll-out switch, blocked vent switch, vent damper and drain valve as standard features.

The CGS-C specification table prints the ratings: CGS30C (69 MBH input, 57 MBH DOE heating capacity, 43 MBH AHRI net steam, 179 steam sq ft, 82.0% AFUE, 4" flue, 350 lb), CGS40C (103/84/63 MBH, 263 sq ft, 82.0%, 5", 420 lb), CGS50C (138/113/85 MBH, 354 sq ft, 82.0%, 6", 485 lb), CGS60C (172/142/107 MBH, 446 sq ft, 82.1%, 6", 555 lb), CGS70C (207/171/128 MBH, 533 sq ft, 82.1%, 7", 620 lb) and CGS80C (241/199/149 MBH, 621 sq ft, 82.2%, 7", 690 lb). Net AHRI steam ratings use a 1.333 piping and pickup allowance, and ratings are for sea level to 2,000 feet with a 4% reduction per 1,000 feet above that. The gas-to-LP conversion kits are listed by model and are available for installations up to 2,000 feet only.

Boilers.ca documents all six sizes at model level from the specification sheet and links the published I&O manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current New Yorker gas-fired steam boiler: CGS30C to CGS80C (six sizes)
  • Up to 82.2% AFUE; 69–241 MBH input
  • AHRI net steam ratings 43–149 MBH (1.333 piping and pickup allowance)
  • Fully packaged with built-in draft diverter, probe-type LWCO and vent damper
  • Natural or LP gas with conversion kits available to 2,000 feet
  • Optional pre-cut, pre-threaded near-boiler piping kit (P/N 850095U)
  • Model-level pages published on Boilers.ca; product specifications and I&O manual linked here

10-year limited warranty per the CGS-C specification sheet; see the installing contractor for warranty information.

Models

CGS-C models

One canonical page per model with input, output and efficiency kept separate.

New Yorker Boiler

New Yorker CGS-C CGS30C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS30C is the smallest CGS-C steam size: 69 MBH input with 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, chimney vented with a 4" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS40C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS40C is the second steam size with a 5-inch flue collar: 103 MBH input with 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, chimney vented with a 5" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS50C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS50C is the mid-size steam model with a 6-inch flue: 138 MBH input with 113 MBH DOE heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, chimney vented with a 6" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS60C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The New Yorker CGS-C CGS60C is the fourth size at 82.1% AFUE: 172 MBH input with 142 MBH DOE heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, chimney vented with a 6" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS70C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The New Yorker CGS-C CGS70C is the first size with a 7-inch flue collar: 207 MBH input with 171 MBH DOE heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, chimney vented with a 7" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS80C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The New Yorker CGS-C CGS80C is the largest CGS-C at 82.2% AFUE: 241 MBH input with 199 MBH DOE heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, chimney vented with a 7" flue collar.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of New Yorker CGS-C CGS30C and New Yorker CGS-C CGS40C and New Yorker CGS-C CGS50C and New Yorker CGS-C CGS60C and New Yorker CGS-C CGS70C and New Yorker CGS-C CGS80C
SpecificationNew Yorker CGS-C CGS30CNew Yorker CGS-C CGS40CNew Yorker CGS-C CGS50CNew Yorker CGS-C CGS60CNew Yorker CGS-C CGS70CNew Yorker CGS-C CGS80C
input-min——————
Input69 MBH103 MBH138 MBH172 MBH207 MBH241 MBH
output-max——————
Efficiency (AFUE)82 %82 %82 %82.1 %82.1 %82.2 %
turndown——————
vent-max-3——————
vent-max-2——————
Approx. ship weight350 lb420 lb485 lb555 lb620 lb690 lb

Read the full comparison: New Yorker CGS-C CGS30C vs CGS40C →

Read the full comparison: New Yorker CGS-C CGS40C vs CGS50C →

Read the full comparison: New Yorker CGS-C CGS50C vs CGS60C →

Read the full comparison: New Yorker CGS-C CGS60C vs CGS70C →

Error codes and alerts

CGS-C alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the New Yorker CGS-C come in?

Six sizes: CGS30C through CGS80C, covering 69, 103, 138, 172, 207 and 241 MBH input with AHRI net steam ratings of 43 to 149 MBH at up to 82.2% AFUE.

Can the CGS-C be converted to propane?

Yes — the specification sheet lists gas-to-LP conversion kits by model (P/N 105801-03 through 105801-08), noting they are available for installations up to 2,000 feet only.

Is a near-boiler piping kit available?

Yes — the specification sheet lists an optional pre-cut, pre-threaded near-boiler piping kit (P/N 850095U) available for 3–6 section boilers.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate