New Yorker PVCG-C PVCG80CN

The New Yorker PVCG-C PVCG80CN is the largest PVCG-C size with a 4-inch vent, in natural gas: 245 MBH input with 208 MBH heating capacity and a 181 MBH net AHRI water rating at 84% AFUE, power vented in 4".

CurrentCanadian status unknown

Key figures

Max input
245 MBH
Max CSA output
AFUE
84 %
Min input
Natural gasHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

New Yorker PVCG-C PVCG80CN in practice

The PVCG-C PVCG80CN is a power-vented cast-iron gas water boiler rated at 245 MBH input. Its row in the PVCG-C specification table prints 208 MBH heating capacity, a 181 MBH net AHRI water rating (1.15 piping and pickup allowance) and 84% AFUE, with a 4" vent, 7 gallons of water content and an approximate ship weight of 525 lb in a 27.75"-wide cabinet.

The boiler is power vented for homes without a chimney and carries an integrated boiler control with high limit, circulator relay and electronic ignition, the energy-saving thermal purge, a factory-installed low water cutoff, a Taco 007e circulator, a Honeywell gas valve, stainless-steel burners and a differential pressure switch. Supply and return connections are 1-1/4 inches with a 3/4" gas connection, 50 PSI maximum allowable working pressure and a 30 PSI relief valve shipped standard.

Boilers.ca documents this SKU at model level from the specification sheet. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 245 MBH residential heat-loss loads
  • Homes without a chimney (power-vented installation)
  • Natural-gas installations

Applicability and support

Model number
PVCG80CN
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.

New Yorker PVCG-C PVCG80CN specifications
SpecificationValueNote
Input
Input245 MBHInput per the PVCG-C specification table ratings row.
Output
Heating capacity208 MBHHeating capacity per the PVCG-C specification table.
Net AHRI water rating181 MBHNet AHRI water rating per the PVCG-C specification table, based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)84 %84.0% AFUE on the PVCG80C rows per the specification table; the page headline is '85% AFUE (most sizes)'.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent diameter4"Vent diameter per the PVCG-C specification table; the boiler is power vented without a chimney and direct-vent conversion kits are listed by model.
VentingPower vented without a chimneyPower vented for installations without a chimney; direct-vent conversion kits are listed by model (P/N 110019-03 through 110019-08).
Physical and connections
Approx. ship weight525 lbApproximate ship weight per the PVCG-C specification table.
Dimensions (width × height × depth)27.75" × 37-3/4" × 27-1/4"PVCG-C dimension table values (dimension A is the model width; overall height and depth are common across the line).
Water content7 galWater content per the PVCG-C specification table.
Supply/return connections1-1/4" supply and 1-1/4" returnWater connection sizes per the PVCG-C specification sheet; maximum allowable working pressure is 50 PSI with a 30 PSI relief valve shipped standard.
Gas connection3/4"Gas connection per the PVCG-C specification table.
Operating limits and other
ControlIntegrated boiler control with thermal purge and factory-installed LWCOElectronic boiler control system includes high limit and circulator relay; Taco 007e circulator, Honeywell gas valve and differential pressure switch standard.
FuelNatural gas ('N' SKU)The ratings table lists each size as an 'N' (natural gas) and a 'P' (LP gas) SKU with different printed inputs.

Frequently asked questions

What are the PVCG-C PVCG80CN's ratings?

245 MBH input, 208 MBH heating capacity, a 181 MBH net AHRI water rating and 84% AFUE with a 4" power-vented connection per the PVCG-C specification table.

Is this a natural gas or propane model?

This SKU ('N' suffix) is the natural-gas row of the PVCG-C table.

Questions about the New Yorker PVCG-C PVCG80CN?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate