New Yorker PVCG-C PVCG30CN
The New Yorker PVCG-C PVCG30CN is the smallest PVCG-C size in natural gas: 70 MBH input with 60 MBH heating capacity and a 52 MBH net AHRI water rating at 85% AFUE, power vented in 3".
Key figures
- Max input
- 70 MBH
- Max CSA output
- —
- AFUE
- 85 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
New Yorker PVCG-C PVCG30CN in practice
The PVCG-C PVCG30CN is a power-vented cast-iron gas water boiler rated at 70 MBH input. Its row in the PVCG-C specification table prints 60 MBH heating capacity, a 52 MBH net AHRI water rating (1.15 piping and pickup allowance) and 85% AFUE, with a 3" vent, 2 gallons of water content and an approximate ship weight of 260 lb in a 12.75"-wide cabinet.
The boiler is power vented for homes without a chimney and carries an integrated boiler control with high limit, circulator relay and electronic ignition, the energy-saving thermal purge, a factory-installed low water cutoff, a Taco 007e circulator, a Honeywell gas valve, stainless-steel burners and a differential pressure switch. Supply and return connections are 1-1/4 inches with a 1/2" gas connection, 50 PSI maximum allowable working pressure and a 30 PSI relief valve shipped standard.
Boilers.ca documents this SKU at model level from the specification sheet. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.
Best suited to
- 70 MBH residential heat-loss loads
- Homes without a chimney (power-vented installation)
- Natural-gas installations
Applicability and support
- Model number
- PVCG30CN
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 70 MBH | Input per the PVCG-C specification table ratings row. |
| Output | ||
| Heating capacity | 60 MBH | Heating capacity per the PVCG-C specification table. |
| Net AHRI water rating | 52 MBH | Net AHRI water rating per the PVCG-C specification table, based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 85 % | 85.0% AFUE per the PVCG-C specification table; the page headline is '85% AFUE (most sizes)'. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Vent diameter | 3" | Vent diameter per the PVCG-C specification table; the boiler is power vented without a chimney and direct-vent conversion kits are listed by model. |
| Venting | Power vented without a chimney | Power vented for installations without a chimney; direct-vent conversion kits are listed by model (P/N 110019-03 through 110019-08). |
| Physical and connections | ||
| Approx. ship weight | 260 lb | Approximate ship weight per the PVCG-C specification table. |
| Dimensions (width × height × depth) | 12.75" × 37-3/4" × 27-1/4" | PVCG-C dimension table values (dimension A is the model width; overall height and depth are common across the line). |
| Water content | 2 gal | Water content per the PVCG-C specification table. |
| Supply/return connections | 1-1/4" supply and 1-1/4" return | Water connection sizes per the PVCG-C specification sheet; maximum allowable working pressure is 50 PSI with a 30 PSI relief valve shipped standard. |
| Gas connection | 1/2" | Gas connection per the PVCG-C specification table. |
| Operating limits and other | ||
| Control | Integrated boiler control with thermal purge and factory-installed LWCO | Electronic boiler control system includes high limit and circulator relay; Taco 007e circulator, Honeywell gas valve and differential pressure switch standard. |
| Fuel | Natural gas ('N' SKU) | The ratings table lists each size as an 'N' (natural gas) and a 'P' (LP gas) SKU with different printed inputs. |
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the PVCG-C PVCG30CN's ratings?
70 MBH input, 60 MBH heating capacity, a 52 MBH net AHRI water rating and 85% AFUE with a 3" power-vented connection per the PVCG-C specification table.
Is this a natural gas or propane model?
This SKU ('N' suffix) is the natural-gas row of the PVCG-C table.
Questions about the New Yorker PVCG-C PVCG30CN?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- New Yorker PVCG-C PVCG30CN vs PVCG40CNComparison
- New Yorker PVCG-C PVCG30CP vs PVCG30CNComparison
- New Yorker PVCG-C PVCG30CN vs PVCG40CPComparison
- New Yorker PVCG-C PVCG30CPSame series
- New Yorker PVCG-C PVCG40CNSame series
- New Yorker PVCG-C PVCG40CPSame series
- New Yorker PVCG-C PVCG50CNSame series
- New Yorker PVCG-C PVCG50CPSame series
- New Yorker PVCG-C PVCG60CNSame series
- New Yorker PVCG-C PVCG60CPSame series
- New Yorker PVCG-C PVCG70CNSame series
- New Yorker PVCG-C PVCG70CPSame series
- New Yorker PVCG-C PVCG80CNSame series
- New Yorker PVCG-C PVCG80CPSame series
- PVCG-C series hub
- Buying guide
Sources and verification
- New Yorker Boiler — PVCG-C Water Series product page · accessed September 9, 2026
- PVCG-C Water Series Product Specifications (PDF) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.