Skip to content
Boilers.caby ROMA Heating & Cooling

Peerless Boilers · Series

Peerless Boilers Series TCII

The Series TCII is Peerless' current commercial cast-iron steam or hot water boiler — 15 sizes TCII-04 through TCII-18 with gas inputs of 1,143 to 5,553 MBH (oil 1,106–5,390 MBH, 7.9–38.5 GPH), gross outputs of 931 to 4,622 MBH and thermal efficiencies up to 85.8%, on a forced-draft power burner with flexible graphite port connectors and individual draw rods.

Current seriesunknownNatural gascommercial

Series facts

Type
non-condensing
Efficiency
85.8% thermal-efficiency
Fuel
The official page lists the line for gas, oil or combination gas/oil firing; this gas-focused record covers the printed gas and gas/oil configurations (oil-only firing is described in the copy but not recorded as a fuel).
Venting
Forced draft with a power burner: the product page lists forced-draft venting and power-burner combustion for the line; the catalog lists burner options including Beckett, Carlin, Power Flame and Riello.
Models documented
15
Warranty
Not verified

The page copy states thermal efficiencies of up to 85.8%; the in-page table prints oil thermal efficiency of 83.9–85.8% and gas thermal efficiency of 81.4–83.2%.

About the Series TCII

The Series TCII is Peerless' current commercial cast-iron boiler, listed under Commercial Boilers – Gas Boilers on the official site. The page copy describes a steam or hot water boiler for gas, oil or combination gas/oil-fired applications 'designed for higher efficiencies', available in 15 sizes with inputs of 1,143 MBH to 5,553 MBH and thermal efficiencies of up to 85.8%. It highlights flexible graphite port connectors and individual draw rods for easy installation and a tight secure fit between sections, and notes that tankless coils can be added where domestic hot water is required.

The in-page ratings table covers 15 sizes, TCII-04 through TCII-18: oil inputs of 7.9–38.5 GPH (1,106–5,390 MBH), gas inputs of 1,143–5,553 MBH, gross outputs of 931–4,622 MBH, net steam ratings of 2,908–14,954 sq ft (810–4,019 MBH) and net water ratings of 698–3,589 MBH. The table prints oil combustion efficiency of 86.0–86.2% and thermal efficiency of 83.9–85.8%, and gas combustion efficiency of 83.4–83.6% and thermal efficiency of 81.4–83.2%.

Boilers.ca records the Series TCII as a current commercial hub with the printed sizes and ratings summarized in this copy and the installation manual and catalog literature linked. No official Canadian-sales statement was found — research reviewed US-site data only — so canadianStatus stays 'unknown', and commercial gas, combustion and venting work belongs with a licensed contractor.

Highlights

  • Current Peerless commercial cast-iron steam/hot water line: TCII-04 to TCII-18 (15 sizes)
  • Gas inputs 1,143–5,553 MBH; oil 1,106–5,390 MBH (7.9–38.5 GPH)
  • Gross outputs 931–4,622 MBH; net steam 2,908–14,954 sq ft; net water 698–3,589 MBH
  • Thermal efficiencies up to 85.8% (oil) / 83.2% (gas) per the in-page table
  • Flexible graphite port connectors, individual draw rods; optional tankless coils
  • Commercial hub documentation; TC8058 R2 manual and CUT-TCII R3 catalog linked here

Models

Series TCII models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-04 is a current commercial cast-iron steam or hot water boiler firing 1143 MBH gas (7.9 GPH oil) for 931 MBH gross output, a 698 MBH net steam rating (2908 sq ft) and a 810 MBH net water rating at 81.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-05 is a current commercial cast-iron steam or hot water boiler firing 1458 MBH gas (10.2 GPH oil) for 1194 MBH gross output, a 896 MBH net steam rating (3733 sq ft) and a 1038 MBH net water rating at 81.9% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-06 is a current commercial cast-iron steam or hot water boiler firing 1773 MBH gas (12.2 GPH oil) for 1458 MBH gross output, a 1110 MBH net steam rating (4625 sq ft) and a 1268 MBH net water rating at 82.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-07 is a current commercial cast-iron steam or hot water boiler firing 2088 MBH gas (14.4 GPH oil) for 1722 MBH gross output, a 1330 MBH net steam rating (5542 sq ft) and a 1497 MBH net water rating at 82.5% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-08 is a current commercial cast-iron steam or hot water boiler firing 2403 MBH gas (16.6 GPH oil) for 1985 MBH gross output, a 1541 MBH net steam rating (6421 sq ft) and a 1726 MBH net water rating at 82.6% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-09 is a current commercial cast-iron steam or hot water boiler firing 2718 MBH gas (18.8 GPH oil) for 2249 MBH gross output, a 1745 MBH net steam rating (7275 sq ft) and a 1956 MBH net water rating at 82.7% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-10 is a current commercial cast-iron steam or hot water boiler firing 3033 MBH gas (21 GPH oil) for 2513 MBH gross output, a 1951 MBH net steam rating (8129 sq ft) and a 2185 MBH net water rating at 82.8% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-11 is a current commercial cast-iron steam or hot water boiler firing 3348 MBH gas (23 GPH oil) for 2776 MBH gross output, a 2155 MBH net steam rating (8979 sq ft) and a 2414 MBH net water rating at 82.9% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-12 is a current commercial cast-iron steam or hot water boiler firing 3663 MBH gas (25.5 GPH oil) for 3040 MBH gross output, a 2360 MBH net steam rating (9833 sq ft) and a 2643 MBH net water rating at 83% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-13 is a current commercial cast-iron steam or hot water boiler firing 3978 MBH gas (27.5 GPH oil) for 3304 MBH gross output, a 2565 MBH net steam rating (10688 sq ft) and a 2873 MBH net water rating at 83% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-14 is a current commercial cast-iron steam or hot water boiler firing 4293 MBH gas (29.5 GPH oil) for 3567 MBH gross output, a 2769 MBH net steam rating (11538 sq ft) and a 3102 MBH net water rating at 83.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-15 is a current commercial cast-iron steam or hot water boiler firing 4608 MBH gas (32 GPH oil) for 3851 MBH gross output, a 2974 MBH net steam rating (12392 sq ft) and a 3331 MBH net water rating at 83.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-16 is a current commercial cast-iron steam or hot water boiler firing 4923 MBH gas (34 GPH oil) for 4095 MBH gross output, a 3179 MBH net steam rating (13246 sq ft) and a 3561 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-17 is a current commercial cast-iron steam or hot water boiler firing 5238 MBH gas (36.5 GPH oil) for 4358 MBH gross output, a 3384 MBH net steam rating (14100 sq ft) and a 3790 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-18 is a current commercial cast-iron steam or hot water boiler firing 5553 MBH gas (38.5 GPH oil) for 4622 MBH gross output, a 3589 MBH net steam rating (14954 sq ft) and a 4019 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Compare models in this series

Comparison of Peerless Series TCII TCII-04 and Peerless Series TCII TCII-05 and Peerless Series TCII TCII-06 and Peerless Series TCII TCII-07 and Peerless Series TCII TCII-08 and Peerless Series TCII TCII-09 and Peerless Series TCII TCII-10 and Peerless Series TCII TCII-11 and Peerless Series TCII TCII-12 and Peerless Series TCII TCII-13 and Peerless Series TCII TCII-14 and Peerless Series TCII TCII-15 and Peerless Series TCII TCII-16 and Peerless Series TCII TCII-17 and Peerless Series TCII TCII-18
SpecificationPeerless Series TCII TCII-04Peerless Series TCII TCII-05Peerless Series TCII TCII-06Peerless Series TCII TCII-07Peerless Series TCII TCII-08Peerless Series TCII TCII-09Peerless Series TCII TCII-10Peerless Series TCII TCII-11Peerless Series TCII TCII-12Peerless Series TCII TCII-13Peerless Series TCII TCII-14Peerless Series TCII TCII-15Peerless Series TCII TCII-16Peerless Series TCII TCII-17Peerless Series TCII TCII-18
input-min
input-max
output-max
afue
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Peerless Series TCII TCII-04 vs TCII-05

Read the full comparison: Peerless Series TCII TCII-05 vs TCII-06

Read the full comparison: Peerless Series TCII TCII-06 vs TCII-07

Read the full comparison: Peerless Series TCII TCII-07 vs TCII-08

Error codes and alerts

Series TCII alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Peerless Series TCII come in?

Fifteen commercial sizes per the in-page table — TCII-04 through TCII-18 — with gas inputs of 1,143–5,553 MBH, oil inputs of 7.9–38.5 GPH and gross outputs of 931–4,622 MBH.

What fuels can the Series TCII use?

The official page lists gas, oil or combination gas/oil-fired applications on a forced-draft power burner; Boilers.ca's gas-focused record covers the printed gas and gas/oil configurations.

Is the Series TCII available in Canada?

No official Canadian-sales statement was found in the official pages and manuals reviewed on September 9, 2026 (US-site data only), so canadianStatus is recorded as 'unknown'. Confirm supply through a licensed distributor.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate