Raypak Delta Limited H3-749B

The Raypak Delta Limited H3-749B is an indoor non-condensing copper-fin commercial hydronic boiler rated 750 MBTUH input and 630 MBTUH Type H output at 84% thermal efficiency, with 2-stage firing and a 8 in flue.

CurrentCanadian status unknown

Key figures

Max input
750 MBH
Max CSA output
630 MBH
AFUE
—
Min input
—
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Raypak Delta Limited H3-749B in practice

The H3-749B is the 750 MBTUH size of the Delta Limited, Raypak's indoor non-condensing copper-fin boiler based on the same basic design as the Hi Delta with a reduced feature set at reduced cost. The official submittals print 750 MBTUH input and 630 MBTUH Type H output at 84% thermal efficiency, with 2-stage firing, a 67-1/2 in casing width, 2" NPT water connections, a 1-1/4" NPT gas connection, a 8 in flue, 675 lb approximate shipping weight and <6 A boiler amp draw.

The model-number key in the I&O manual (241330) reads H for hydronic and the following digit for firing mode — 4 for on-off, 3 for 2-stage, 8 for 3-stage and 9 for 4-stage — which is how the page's H4/H3/H8/H9 prefixes match the printed stage counts. Submittals 242015 (399B-899B) and 242016 (989B-2339B) carry the rating tables above.

Best suited to

  • Commercial hydronic loads near 750 MBTUH input
  • Budget-sensitive plants wanting the Hi Delta design with a reduced feature set
  • Indoor installations on Category I or III venting

Applicability and support

Model number
H3-749B
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Raypak. Units are shown with every value; notes flag conflicting sources or missing figures.

Raypak Delta Limited H3-749B specifications
SpecificationValueNote
Input
Input750 MBHRated input 750 MBTUH printed in the Delta Limited submittals (242015/242016) and the product page model rows.
Output
Output630 MBHType H (hydronic) output 630 MBTUH printed in the Delta Limited submittals at 84% thermal efficiency.
Efficiency
AHRI thermal efficiency84 %84% Type H thermal efficiency per the Delta Limited submittals and product page model rows.
Venting and air
Flue outlet8 inFlue connection (K) per the Delta Limited submittals.
Venting categoryCategory I & IIINon-condensing Category I or III venting per the product page model rows.
Physical and connections
Width (A)67-1/2 inDimension A printed in the Delta Limited submittals.
Water connection2" NPTWater connection (H NPT) per the Delta Limited submittals.
Gas connection1-1/4" NPTGas connection (G NPT, natural gas) per the Delta Limited submittals; propane connection sizes are printed separately.
Weight675 lbApproximate shipping weight 675 lb printed in the Delta Limited submittals.
Electrical
Electrical120 VAC, 1-phase; <6 A boiler drawOperating voltage and boiler amp draw from the Delta Limited submittals and product page model rows.
Operating limits and other
Firing stages2 firing stagesFiring stages printed in the Delta Limited submittals; the manual's model-number key maps the first digit (4 = on-off, 3 = 2-stage, 8 = 3-stage, 9 = 4-stage).
Turndown2:1Turndown from the product page model rows, matching the printed firing-stage count.
Maximum water flow90 GPMMaximum water flow from the product page model rows.
FuelNatural gas or propaneNatural gas or propane; the submittals print natural-gas and propane rates.

Frequently asked questions

What are the Delta Limited H3-749B ratings?

The official submittals print 750 MBTUH input, 630 MBTUH Type H output at 84% thermal efficiency, with 2-stage firing.

What does the model number H3-749B mean?

The I&O manual's key reads H for hydronic heating and the following digit for firing mode: 4 = on-off, 3 = 2-stage, 8 = 3-stage and 9 = 4-stage, followed by the approximate MBTUH size.

Can the H3-749B run on propane?

Yes — the submittals print natural-gas and propane rates and connection sizes for this size.

Questions about the Raypak Delta Limited H3-749B?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.