Skip to content
Boilers.caby ROMA Heating & Cooling

Raypak · Series

Raypak MVB Category I & III

The MVB Category I & III is the non-condensing member of Raypak's modulating vertical MVB boiler platform — models H7-504A through H7-2004A with Category I or III venting and public English/French I&O documentation.

Current seriesunknownNatural gascommercial

Series facts

Type
non-condensing
Efficiency
Unknown
Fuel
Natural gas per the captured page; propane configuration is not reprinted on the captured text.
Venting
Category I or III (non-condensing) venting on the same modulating vertical MVB platform.
Models documented
5
Warranty
Not verified

About the MVB Category I & III

The MVB Category I and III is the non-condensing version of Raypak's MVB modulating vertical boiler platform: the same vertical modulating design but vented as a Category I or III appliance rather than condensing Category IV.

Model sizes printed in the documentation rows are H7-504A, H7-754A, H7-1104A, H7-1504A and H7-2004A (the 504A–2004A family). Efficiency figures are published in spec sheets rather than the captured page text.

Raypak publishes I&O manual 241512 with English and French editions for the Category I & III models. No explicit Canadian-availability sentence is printed on the page.

Highlights

  • Non-condensing modulating vertical boiler on the MVB platform
  • Models H7-504A, 754A, 1104A, 1504A, 2004A
  • Category I or III venting
  • I&O manual 241512 public in English and French

Models

MVB Category I & III models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
420 MBH
AFUE

The Raypak MVB H7-504A is a non-condensing modulating vertical commercial hydronic boiler rated 500 MBTUH input and 420 MBTUH output at 84% thermal efficiency, with Category I & III venting and a 8 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
630 MBH
AFUE

The Raypak MVB H7-754A is a non-condensing modulating vertical commercial hydronic boiler rated 750 MBTUH input and 630 MBTUH output at 84% thermal efficiency, with Category I & III venting and a 10 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
924 MBH
AFUE

The Raypak MVB H7-1104A is a non-condensing modulating vertical commercial hydronic boiler rated 1100 MBTUH input and 924 MBTUH output at 84% thermal efficiency, with Category I & III venting and a 10 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,260 MBH
AFUE

The Raypak MVB H7-1504A is a non-condensing modulating vertical commercial hydronic boiler rated 1500 MBTUH input and 1260 MBTUH output at 84% thermal efficiency, with Category I & III venting and a 12 in flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,679 MBH
AFUE

The Raypak MVB H7-2004A is a non-condensing modulating vertical commercial hydronic boiler rated 1999 MBTUH input and 1679 MBTUH output at 84% thermal efficiency, with Category I & III venting and a 14 in flue.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Raypak MVB H7-504A and Raypak MVB H7-754A and Raypak MVB H7-1104A and Raypak MVB H7-1504A and Raypak MVB H7-2004A
SpecificationRaypak MVB H7-504ARaypak MVB H7-754ARaypak MVB H7-1104ARaypak MVB H7-1504ARaypak MVB H7-2004A
input-min
Input500 MBH750 MBH1,100 MBH1,500 MBH1,999 MBH
Output420 MBH630 MBH924 MBH1,260 MBH1,679 MBH
afue
Turndown1.7:11.7:11.7:11.7:11.7:1
vent-max-3
vent-max-2
Weight600 lb670 lb720 lb780 lb940 lb

Read the full comparison: Raypak MVB H7-504A vs MVB H7-754A

Read the full comparison: Raypak MVB H7-754A vs MVB H7-1104A

Read the full comparison: Raypak MVB H7-1104A vs MVB H7-1504A

Read the full comparison: Raypak MVB H7-1504A vs MVB H7-2004A

Error codes and alerts

MVB Category I & III alerts

  • OUTLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • INLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • GAS PRESSVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGNITIONVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT TRIPVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLAMEVERSA IC control with PIM (error items shown on the touchscreen display)
  • ID CARDVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGN CTRLVERSA IC control with PIM (error items shown on the touchscreen display)
  • DELTA TVERSA IC control with PIM (error items shown on the touchscreen display)
  • LOW 24VACVERSA IC control with PIM (error items shown on the touchscreen display)
  • BLOW SPEEDVERSA IC control with PIM (error items shown on the touchscreen display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

How does the MVB Category I & III differ from the Category IV MVB?

The Category IV models are condensing boilers with Category IV venting; the Category I & III models are the same modulating vertical platform in non-condensing form with Category I or III venting.

What sizes does the non-condensing MVB come in?

The product page prints H7-504A, H7-754A, H7-1104A, H7-1504A and H7-2004A.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate