Skip to content
Boilers.caby ROMA Heating & Cooling

Raypak · Series

Raypak XVers L

The XVers L extends Raypak's XVers condensing family down to 'sizes from 399 to 850 MBTUH' — models H7-406L through H7-856L — with cold-water-tolerant design, the Raymote control option and public English/French I&O manuals.

Current seriesunknownNatural gascommercial

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Natural gas per the captured page; propane configuration is not reprinted on the captured text.
Venting
Unknown
Models documented
5
Warranty
Not verified

About the XVers L

Raypak presents the XVers L as the smaller addition to the XVers condensing family: 'available in sizes from 399 to 850 MBTUH … expands the reliable XVers family', with marketing copy emphasizing cold-water tolerance and the Raymote control option. Model numbers printed in the page's documentation rows are H7-406L, H7-506L, H7-606L, H7-726L and H7-856L (406–856 MBH).

The efficiency and turndown figures sit in the XVers L spec sheets rather than the captured page text, so Boilers.ca does not print a percentage it could not verify from the official pages.

Public downloads from the product page include the I&O manual 241782 with its French edition and an XVers L brochure. As with other Raypak lines, no explicit Canadian-availability sentence is printed.

Highlights

  • Condensing line extending the XVers family to 399 – 850 MBTUH
  • Models H7-406L / H7-506L / H7-606L / H7-726L / H7-856L (406–856 MBH)
  • Cold-water tolerant design; Raymote option (page marketing)
  • I&O manual 241782 public in English and French

Models

XVers L models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
—
Output (max)
391 MBH
AFUE
—

The Raypak XVers L H7-406L is a condensing firetube commercial hydronic boiler rated 399 MBTUH input and 391 MBTUH output at 98% AHRI thermal efficiency, with 10:1 turndown, Category IV venting and a maximum water flow of 73 gpm per the 241896 submittal.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
489 MBH
AFUE
—

The Raypak XVers L H7-506L is a condensing firetube commercial hydronic boiler rated 500 MBTUH input and 489 MBTUH output at 97.8% AHRI thermal efficiency, with 10:1 turndown, Category IV venting and a maximum water flow of 73 gpm per the 241896 submittal.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
586 MBH
AFUE
—

The Raypak XVers L H7-606L is a condensing firetube commercial hydronic boiler rated 600 MBTUH input and 586 MBTUH output at 97.6% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and a maximum water flow of 73 gpm per the 241896 submittal.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
705 MBH
AFUE
—

The Raypak XVers L H7-726L is a condensing firetube commercial hydronic boiler rated 725 MBTUH input and 705 MBTUH output at 97.3% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and a maximum water flow of 114 gpm per the 241896 submittal.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
826 MBH
AFUE
—

The Raypak XVers L H7-856L is a condensing firetube commercial hydronic boiler rated 850 MBTUH input and 826 MBTUH output at 97.2% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and a maximum water flow of 114 gpm per the 241896 submittal.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Raypak XVers L H7-406L and Raypak XVers L H7-506L and Raypak XVers L H7-606L and Raypak XVers L H7-726L and Raypak XVers L H7-856L
SpecificationRaypak XVers L H7-406LRaypak XVers L H7-506LRaypak XVers L H7-606LRaypak XVers L H7-726LRaypak XVers L H7-856L
input-min—————
Input399 MBH500 MBH600 MBH725 MBH850 MBH
Output391 MBH489 MBH586 MBH705 MBH826 MBH
afue—————
Turndown10:110:17:17:17:1
vent-max-3—————
vent-max-2—————
Weight547 lb611 lb603 lb710 lb720 lb

Read the full comparison: Raypak XVers L H7-406L vs XVers L H7-506L →

Read the full comparison: Raypak XVers L H7-506L vs XVers L H7-606L →

Read the full comparison: Raypak XVers L H7-606L vs XVers L H7-726L →

Read the full comparison: Raypak XVers L H7-726L vs XVers L H7-856L →

Error codes and alerts

XVers L alerts

  • OUTLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • INLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • GAS PRESSVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGNITIONVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT TRIPVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLAMEVERSA IC control with PIM (error items shown on the touchscreen display)
  • ID CARDVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGN CTRLVERSA IC control with PIM (error items shown on the touchscreen display)
  • DELTA TVERSA IC control with PIM (error items shown on the touchscreen display)
  • LOW 24VACVERSA IC control with PIM (error items shown on the touchscreen display)
  • BLOW SPEEDVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW ERRORVERSA IC control with PIM (error items shown on the touchscreen display)
  • UNDER FLOWVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW WARNINGVERSA IC control with PIM (error items shown on the touchscreen display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

How does the XVers L relate to the XVers KOR?

Raypak markets the XVers L as the 399–850 MBTUH addition that 'expands the reliable XVers family'; the XVers KOR is the larger condensing firetube line (1007–4007 MBH).

Which XVers L models exist?

The product page prints H7-406L, H7-506L, H7-606L, H7-726L and H7-856L, i.e. 406 to 856 MBH.

Is there a French XVers L manual?

Yes — Raypak publishes I&O 241782-FR alongside the English 241782 on the product page.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate