The Challenger CC125 Combi is the largest 'Two in One' combi with a published row: 20 to 125 MBH at 95% AFUE with a 6.3:1 turndown and 3.0 GPM of DHW at a 70°F rise. Discontinued years before the November 3, 2025 cessation.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
AFUE
95 %
Min input
20 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Challenger CC125 Combi in practice

The CC125 combi row of the archived 2019 comparison table is the top of the documented combi range: 20 to 125 MBH of input at 95% AFUE with a 6.3:1 turndown, a 111 MBH DOE capacity, a 97 MBH net AHRI rating and 3.0 GPM of DHW flow at a 70°F rise. Its 20 MBH minimum is lower than the CC125 Solo's 33 MBH, which is what makes its 6.3:1 turndown consistent.

An official manual title also names a CC125H in the combi family, alongside the CC105 and CC125 covered by the Challenger Combi User's Information Manual. The CC125 combi condenses in both space-heating and DHW modes through the 'Two in One' heat exchanger design and long predates the November 3, 2025 cessation.

Best suited to

  • Owners identifying a CC125 combi from its rating plate and 2019-era comparison row
  • Homes whose load and hot-water draws matched the top Challenger combi package
  • Technicians tracing the CC125H variant named in official combi manual titles

Applicability and support

Model number
CC125
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Challenger CC125 Combi specifications
SpecificationValueNote
Input
Heating input, minimum20 MBHThe combi comparison row prints a 20 MBH minimum — lower than the CC125 Solo's 33 MBH.
Heating input, maximum125 MBHThe combi comparison row prints a 20 MBH minimum — lower than the CC125 Solo's 33 MBH.
Output
DOE heating capacity111 MBHPer the product-page spec table.
Net AHRI rating97 MBHPer the product-page spec table.
Efficiency
Efficiency (AFUE)95 %95% AFUE on the CC125 combi row of the 2019 product-comparison table.
Domestic hot water
DHW output at 70°F rise3 GPMPer the 2019 product-comparison table.
Operating limits and other
Turndown ratio6.3:1125 MBH divided by the 20 MBH minimum equals 6.25:1, matching the printed 6.3:1.
FuelNatural gas or propaneThe 2019 comparison table prints NG/LP on every Challenger row.

Frequently asked questions

What is the CC125H mentioned in some Challenger documents?

The Challenger Combi User's Information Manual title covers the CC105, CC125 and CC125H models. The CC125H is named in that official title; the research bundle does not print a separate rating row for it.

How much hot water does the CC125 Combi deliver?

3.0 GPM of DHW flow at a 70°F rise, per the 2019 product-comparison table — the highest published DHW figure of the Challenger combi rows.

Questions about the Triangle Tube Challenger CC125 Combi?