Triangle Tube Phase III TR-60

The Triangle Tube Phase III TR-60 is a discontinued 56-gallon indirect water heater with 8 gallons of boiler water, 24 sq ft of heating surface and a printed first-hour flow of 410 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.

DiscontinuedHistorically in Canada

Key figures

Max input
Max CSA output
AFUE
Min input
Natural gasPropaneDHW-only (tankless)residential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Phase III TR-60 in practice

The Phase III TR-60 is a 56-gallon indirect water heater in the TR family of Triangle Tube's discontinued Phase III line, documented in the archived official installation and operation manual. The printed specifications table lists 8 gallons of boiler water, 24 sq ft of heating surface, 1-1/2 ft of boiler-side head loss, 1" domestic and 1-1/4" boiler connections, a 51" drywell and a 220 lb empty weight.

The performance table prints a 270 MBH boiler heating capacity, 110 gal/10 min peak flow, 410 gal/hr first-hour flow, 360 gal/hr continuous flow and a 18 gpm minimum circulator flow at 50°F domestic cold water inlet, 140°F domestic hot water outlet and 200°F boiler water supply. The Phase III stores domestic water in a stainless steel tank and reheats it through the coil; vertical installation only, with maximum 190°F domestic and 210°F boiler water temperatures.

Best suited to

  • Owners of an installed Phase III TR-60 identifying its capacity and performance
  • Repair-or-replace decisions comparing a Phase III with the current Cardinal / Smart 316 line
  • Contractors matching a Phase III tank to its archived manual before service

Applicability and support

Model number
TR-60
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Phase III TR-60 specifications
SpecificationValueNote
Domestic hot water
Domestic water capacity56 galPer the archived manual's dimensions and specifications table.
Peak flow110 gal/10 minPer the archived manual's performance table.
First hour flow410 gal/hrPer the archived manual's performance table at 50°F inlet / 140°F outlet / 200°F boiler supply.
Continuous flow360 gal/hrPer the archived manual's performance table.
Physical and connections
Boiler water volume8 galPer the archived manual's specifications table.
Heating surface24 sq ftPer the archived manual's specifications table.
Head loss, boiler side1-1/2 ftPer the archived manual's specifications table.
Domestic connection1"Per the archived manual's specifications table.
Boiler connection1-1/4"Per the archived manual's specifications table.
Drywell length51 inPer the archived manual's specifications table.
Empty weight220 lbPer the archived manual's specifications table.
Operating limits and other
Boiler heating capacity270 MBHPer the archived manual's performance table.
Minimum circulator flow18 GPMPer the archived manual's performance table.

Frequently asked questions

What are the Phase III TR-60 ratings?

The archived manual prints 56 gallons of domestic capacity, 270 MBH boiler heating capacity, 410 gal/hr first-hour flow and a 18 gpm minimum circulator flow.

Is the Phase III still sold?

No. It is a discontinued line documented in an archived official manual; Triangle Tube's current indirect water heaters are the Cardinal and Smart 316 families.

What conditions are the Phase III ratings based on?

The performance tables are printed at 50°F domestic cold water inlet, 140°F domestic hot water outlet and 200°F boiler water supply, with additional tables for other supply temperatures.

Questions about the Triangle Tube Phase III TR-60?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate