Skip to content
Boilers.caby ROMA Heating & Cooling

U.S. Boiler Company · K2

U.S. Boiler Company K2WT-180M

The U.S. Boiler Company K2WT-180M is the high-altitude variant of the 180, stated for installations above 2,000 feet: 18–180 MBH input with 168 MBH DOE heating capacity and a 146 MBH net AHRI water rating at 94.5% AFUE on the K2 condensing platform.

CurrentCanadian status unknown

Key figures

Max input
180 MBH
Max CSA output
AFUE
94.5 %
Min input
18 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

U.S. Boiler Company K2WT-180M in practice

The K2WT-180M is a K2 watertube condensing gas boiler rated at 18–180 MBH input. Its row in the K2 Product Data Sheet (Form USBL14061) prints 168 MBH DOE heating capacity, a 146 MBH net AHRI water rating and 94.5% AFUE, and the data sheet states the 180M is for installations above 2,000 feet.

The boiler weighs about 119 lb, vents in 3" with horizontal and vertical configurations up to 135 equivalent feet per side, and connects on 1" NPT supply and return with a 1/2" gas line. Standard equipment includes the Sage2.3 control with touch screen, a pre-installed boiler-loop circulator, a universal vent connection for CPVC/PVC, polypropylene and stainless steel, a flow switch, supply/return/high-limit water sensors and a pre-installed hanging bracket and wall-mount kit.

Boilers.ca documents this size at model level from the K2 Product Data Sheet for identification and service planning; the K2 Firetube and K2 Combi siblings are covered on the K2 series page because no printed rating table is published for them. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 18-to-180 MBH residential heat-loss loads
  • Homes needing the wider K2 cabinet and 3-inch venting
  • Buyers comparing K2 watertube sizes against the K2 Firetube line

Applicability and support

Model number
K2WT-180M
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by U.S. Boiler Company. Units are shown with every value; notes flag conflicting sources or missing figures.

U.S. Boiler Company K2WT-180M specifications
SpecificationValueNote
Input
Input, minimum18 MBHMinimum input per the K2 Product Data Sheet ratings table.
Input, maximum180 MBHMaximum input per the K2 Product Data Sheet ratings table (performance shown for elevations to 2,000 ft).
Output
DOE heating capacity168 MBHDOE heating capacity per the K2 Product Data Sheet ratings table.
Net AHRI water rating146 MBHNet AHRI water rating per the K2 Product Data Sheet ratings table.
Efficiency
Efficiency (AFUE)94.5 %94.5% AFUE per the K2 Product Data Sheet; the 180M is stated for installations above 2,000 feet.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent size3"Vent size per the K2 Product Data Sheet: 3". Typical venting configurations are horizontal and vertical up to 135 equivalent feet each.
VentingDirect vent, sealed combustion; universal connection for CPVC/PVC, polypropylene and stainless steelUniversal exhaust vent connection per the Product Data Sheet; horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations illustrated, plus polypropylene and stainless chimney-chase options.
Physical and connections
Approx. net weight119 lbNet weight per the K2 Product Data Sheet ratings table.
Dimensions (A × B × C)20-3/16" × 4-7/16" × 8" (A × B × C)K2 dimension table values; the open control door extends dimension A by 15 inches.
Supply/return connections1" NPT supply and 1" NPT returnWater connection sizes per the K2 Product Data Sheet dimension drawing.
Gas connection1/2" gas line per the dimension drawingGas connection per the K2 Product Data Sheet dimension drawing; LP conversion kits are sold separately by size.
Operating limits and other
ControlSage2.3 Control System with LCD touch screenSage2.3 control with self-guided menus, built-in diagnostics, two additional circulator outputs, eight-boiler sequencer, outdoor reset, DHW priority and warm-weather shutdown per the Product Data Sheet.
FuelNatural gas (LP conversion kit sold separately)Boilers shipped set for natural gas; LP conversion kits are listed by size (080B–100B P/N 107873-01, 120B–150B P/N 107874-01, 180B P/N 107875-01, 180M P/N 108101-01).

Frequently asked questions

What are the K2WT-180M's ratings?

18–180 MBH input, 168 MBH DOE heating capacity, a 146 MBH net AHRI water rating and 94.5% AFUE per the K2 Product Data Sheet.

What venting does the K2WT-180M use?

3" venting per the K2 Product Data Sheet, with typical horizontal and vertical configurations up to 135 equivalent feet per side and a universal connection accepting CPVC/PVC, polypropylene and stainless steel.

Questions about the U.S. Boiler Company K2WT-180M?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate