Skip to content
Boilers.caby ROMA Heating & Cooling

Utica Boilers · Error codes

Utica SSC E33 — External Voltage Sent Back to Control Board on DHW T-t or CH T-t Terminals

E33

Needs attentionUtica SSC condensing boilers (E-codes, IOM 240011320 Rev G)

External voltage sent back to control board on DHW T-T or CH T-T terminals. E33 error code is displayed if voltage is sent back to the control board (via DHW T-T or CH T-T). Use a dry contact relay. If error is not corrected for an extended period, this voltage can permanently damage the control board. The table classifies it as blocking.

Applies to

This domestic hot water fault code is displayed by the SSC control on SSC models (UBSSC-050 through UBSSC-299), as documented in Utica SSC Installation and Operation Manual, 240011320 Rev G (240011320 Rev G). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: SSC control. Source manual: 240011320 Rev G.

Why a code is not a diagnosis

A DHW code involves the hot-water side: sensors, flow, the mixing/bypass valve or the DHW heat exchanger. It does not say whether the fix is a sensor, a valve or a flush.

Safe things to observe

  • Note the code and whether the problem follows a hot-water draw or appears at all times.

Do not

  • Do not open the appliance to test DHW components yourself.

How professional service helps

  1. A technician tests the DHW sensors, flow switch and valve circuits, and cleans the DHW path where the manual directs.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for Utica Boilers SSC (UBSSC-050 to UBSSC-299).

Frequently asked questions

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.