The Utica UB90-100 is the largest of the three UB90 Series 4 sizes — a 90% AFUE condensing boiler on the cast aluminum heat exchanger with HSI ignition and the Hydrolevel combination high-limit/LWCO control with reset. The UB90 Series 4 page carries current documents (IOM Rev. F), so this model is recorded as current.

CurrentCanadian status unknown

Key figures

Max input
—
Max CSA output
—
AFUE
90 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Utica UB90-100 (Series 4) in practice

The UB90-100 is the largest of the three UB90 Series 4 sizes of the UB90 Series 4 line Utica documents at 90% AFUE: a compact, low-clearance condensing boiler with a cast aluminum heat exchanger with low pressure drop, hot surface ignition (HSI), a Hydrolevel combination high limit/low water cut-off control with boiler water temperature reset, and a stainless steel premix burner, in a sealed combustion design approved for polypropylene venting with an induced draft blower and adjustable exhaust (front, right side or rear).

The product page carries current documents (UB90 Series 4 IOM Rev. F, parts Rev. G, kit instructions and tech bulletins), so this record is productStatus 'current'; the research notes the series is not shown on Utica's condensing category cards. The UB90-50/75/100 sizes belong to this Series 4 record, while the 125-200 MBH sizes are recorded under the separate UB90-200 Series II series (archived documents).

The UB90's Hydrolevel control uses diagnostic indicator lights rather than a discrete fault-code display, so no error-code pages are published for this model. The ratings are the US-market figures Utica prints; no Canadian listing was verified, so canadianStatus stays 'unknown'. Gas work belongs with a licensed contractor against the UB90 Series 4 IOM Rev. F.

Best suited to

  • Low-clearance, limited-space heating-only installations in the UB90-100 class
  • Sealed combustion direct-vent layouts with polypropylene venting and adjustable exhaust directions
  • Owners of an installed Series 4 UB90 identifying their unit and its documentation

Applicability and support

Model number
UB90-100
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Utica UB90-100 (Series 4) specifications
SpecificationValueNote
Efficiency
AFUE90 %90% AFUE as printed on the UB90 Series 4 product page and in the research headline; ENERGY STAR certified.
Venting and air
VentingSealed combustion, direct vent; polypropylene approvedApproved for polypropylene venting per the product page; induced draft blower with adjustable exhaust (front, right side or rear); the inducer motor assembly includes 5 ft of Schedule 80 2" CPVC and a CPVC tee.
Physical and connections
Heat exchangerCast aluminumHigh-efficiency cast aluminum heat exchanger with low pressure drop, as printed on the product page.
BurnerStainless steel premix burnerAs printed on the product page.
Rating50 psi50 psi as recorded in the research headline; the page also lists a 30 psi safety relief valve.
Operating limits and other
Ignition / controlHot surface ignition (HSI) integrated boiler control; Hydrolevel combination high limit and LWCO with boiler water temperature resetAs printed on the product page; a stainless steel premix burner provides corrosion resistance.
Warranty15-year limited warrantyAs printed on the official UB90 product page.

Manuals

Alerts documented for this model

None documented yet.

Services

Frequently asked questions

What is the UB90-100?

It is the largest of the three UB90 Series 4 sizes of the UB90 Series 4 — a 90% AFUE condensing boiler on a cast aluminum heat exchanger with HSI ignition and a Hydrolevel combination control.

Is the UB90 Series 4 a combi boiler?

No — it is a heating-only hot water boiler; domestic hot water is handled separately.

Does the UB90 display fault codes?

No — the Hydrolevel control shows diagnostic and function indicator lights rather than a discrete code list, so no error-code pages are published for the series.

Questions about the Utica UB90-100 (Series 4)?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate