Utica Boilers · UB90 Series 4 (UB90-50 to UB90-100)
Utica UB90-75 (Series 4)
The Utica UB90-75 is the middle of the three UB90 Series 4 sizes — a 90% AFUE condensing boiler on the cast aluminum heat exchanger with HSI ignition and the Hydrolevel combination high-limit/LWCO control with reset. The UB90 Series 4 page carries current documents (IOM Rev. F), so this model is recorded as current.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 90 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Utica UB90-75 (Series 4) in practice
The UB90-75 is the middle of the three UB90 Series 4 sizes of the UB90 Series 4 line Utica documents at 90% AFUE: a compact, low-clearance condensing boiler with a cast aluminum heat exchanger with low pressure drop, hot surface ignition (HSI), a Hydrolevel combination high limit/low water cut-off control with boiler water temperature reset, and a stainless steel premix burner, in a sealed combustion design approved for polypropylene venting with an induced draft blower and adjustable exhaust (front, right side or rear).
The product page carries current documents (UB90 Series 4 IOM Rev. F, parts Rev. G, kit instructions and tech bulletins), so this record is productStatus 'current'; the research notes the series is not shown on Utica's condensing category cards. The UB90-50/75/100 sizes belong to this Series 4 record, while the 125-200 MBH sizes are recorded under the separate UB90-200 Series II series (archived documents).
The UB90's Hydrolevel control uses diagnostic indicator lights rather than a discrete fault-code display, so no error-code pages are published for this model. The ratings are the US-market figures Utica prints; no Canadian listing was verified, so canadianStatus stays 'unknown'. Gas work belongs with a licensed contractor against the UB90 Series 4 IOM Rev. F.
Best suited to
- Low-clearance, limited-space heating-only installations in the UB90-75 class
- Sealed combustion direct-vent layouts with polypropylene venting and adjustable exhaust directions
- Owners of an installed Series 4 UB90 identifying their unit and its documentation
Applicability and support
- Model number
- UB90-75
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Efficiency | ||
| AFUE | 90 % | 90% AFUE as printed on the UB90 Series 4 product page and in the research headline; ENERGY STAR certified. |
| Venting and air | ||
| Venting | Sealed combustion, direct vent; polypropylene approved | Approved for polypropylene venting per the product page; induced draft blower with adjustable exhaust (front, right side or rear); the inducer motor assembly includes 5 ft of Schedule 80 2" CPVC and a CPVC tee. |
| Physical and connections | ||
| Heat exchanger | Cast aluminum | High-efficiency cast aluminum heat exchanger with low pressure drop, as printed on the product page. |
| Burner | Stainless steel premix burner | As printed on the product page. |
| Rating | 50 psi | 50 psi as recorded in the research headline; the page also lists a 30 psi safety relief valve. |
| Operating limits and other | ||
| Ignition / control | Hot surface ignition (HSI) integrated boiler control; Hydrolevel combination high limit and LWCO with boiler water temperature reset | As printed on the product page; a stainless steel premix burner provides corrosion resistance. |
| Warranty | 15-year limited warranty | As printed on the official UB90 product page. |
Manuals
- UB90 Series 4 IOM Rev. F (PN 240010135)240010135 (Rev. F)
Alerts documented for this model
None documented yet.
Frequently asked questions
What is the UB90-75?
It is the middle of the three UB90 Series 4 sizes of the UB90 Series 4 — a 90% AFUE condensing boiler on a cast aluminum heat exchanger with HSI ignition and a Hydrolevel combination control.
Is the UB90 Series 4 a combi boiler?
No — it is a heating-only hot water boiler; domestic hot water is handled separately.
Does the UB90 display fault codes?
No — the Hydrolevel control shows diagnostic and function indicator lights rather than a discrete code list, so no error-code pages are published for the series.
Questions about the Utica UB90-75 (Series 4)?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Utica Boilers — UB90 Series 4 product page · accessed September 9, 2026
- UB90 Series 4 IOM Rev. F (PN 240010135) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.