The Vitodens 200-W B2HA-285 is the entry size of Viessmann Canada's high-input B2HA line for large homes: 71,000 to 285,000 BTU (21 to 83 kW) of input in a 194 lb wall-hung condensing boiler, with a printed 92% AFUE spec row.

CurrentSold in Canada

Key figures

Max input
285 MBH
Max CSA output
AFUE
92 %
Min input
71 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 200-W B2HA-285 in practice

The B2HA-285 is the smallest model of the Vitodens 200-W B2HA line that Viessmann Canada positions for expanded capacity in large homes. It fires from a 71,000 BTU (21 kW) minimum input up to 285,000 BTU (83 kW) maximum, and the page's spec table prints a 92% AFUE row for it — while marketing copy on the same page separately cites an 'up to 95% AFUE rating' for the product line.

The boiler is gas-fired and wall-mounted with a stainless steel MatriX cylinder burner and Inox-Radial heat exchanger. It weighs 194 lb (88 kg) and measures 19 x 21 x 43½ inches (480 x 530 x 1105 mm), and it runs on natural gas or liquid propane with no fuel-conversion kit required, per the page.

Note that the page's technical table prints legacy B2HB-68 to B2HB-199 rows beside the current B2HA rows; the specifications here are the B2HA-285 figures only. Viessmann markets common venting of up to four boilers for the line, with vent runs up to 180 ft.

Best suited to

  • Large homes whose heat-loss calculation fits up to about 285 MBH
  • Wall-hung installs wanting the 200-W burner and heat-exchanger technology at higher input
  • Comparing against the B2HA-311 before final sizing

Applicability and support

Model number
B2HA-285
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 200-W B2HA-285 specifications
SpecificationValueNote
Input
Input, minimum (natural gas)71 MBH71,000 BTU (21 kW), per the Canadian product page
Input, maximum (natural gas)285 MBH285,000 BTU (83 kW), per the Canadian product page
Efficiency
Efficiency (AFUE)92 %92% AFUE for the B2HA-285 spec row on the Canadian product page; the page's marketing copy separately cites an 'up to 95% AFUE rating'.
Venting and air
Maximum vent run180 ftVent length up to 180 ft per the Canadian product page; common venting of up to four boilers is a series-level option.
Physical and connections
Weight194 lb88 kg
Width19 in480 mm
Depth21 in530 mm
Height43.5 in1105 mm
Operating limits and other
Fuel typeNatural gas (NG) or liquid propane gas (LPG)No fuel-conversion kit required per the Canadian product page.

Frequently asked questions

What is the firing range of the B2HA-285?

From a 71,000 BTU (21 kW) minimum input up to 285,000 BTU (83 kW) maximum on natural gas, per the Canadian product page. The same minimum applies to the B2HA-311 and B2HA-352.

What efficiency does Viessmann publish for the B2HA-285?

The page's spec table prints 92% AFUE for the B2HA-285, while its marketing copy cites an 'up to 95% AFUE rating' for the product line. Boilers.ca keeps the printed spec-row figure.

Is the B2HA-285 a combi boiler?

No combi configuration is listed on the Canadian page; the B2HA is documented as a space-heating boiler, so domestic hot water is handled separately, typically with an indirect tank.

Questions about the Viessmann Vitodens 200-W B2HA-285?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate